2
Technical Support: +44(0)23 9269 6638 (option 3)
PAK200552_01A ©2012 ELMDENE INTERNATIONAL LTD
I
NSTALLATION AND
S
ET
-U
P
50W PoE Injector Installation
1.
Mount the injector on a suitable surface using the four available mounting holes.
2.
Connect the mains input supply cable.
3.
Connect the Cat5/6 input from the network hub or switch to the connector labelled
IN
.
4.
Connect the Cat5/6 PoE output (to the POE1230-C device) to the connector labelled
OUT
.
Note: Ensure all cable connections are correct, prior to applying power to avoid damage to
associated equipment.
POE1230-C Enclosure Mounting
1.
Mount enclosure securely on a sound surface in correct orientation using the four available
mounting holes.
2.
Route network and low voltage output cables via different knockouts and/or rear cable entry
holes.
PoE Charger Connections
Note: Always connect battery first and disconnect last - Do Not Run the unit without the battery
connected.
GND 1 or 2: 0V dc connection
+12V 1 or 2: +12V dc connection
FG: Not Used
- SOL: 0V Solar Panel connection
+ SOL: +Ve Solar Panel connection
- BAT: 0V Battery Connection
+ BAT: +Ve Battery Connection
POE IN: Input PoE Power (from 50W injector)
POE OUT: 802.3af PoE output connection
PoE Charger Indicators
POE - PoE input present
SOL - Solar panel connected
CHA - Battery connected and charging
LOA - 12V dc load connected
REV - Battery connections reversed
Note: If the PoE input is present prior to the battery connections being reversed the load fuse will be blown.
Once all connections have been made and checked apply mains power to PoE injector, the green health LED
will illuminate. On the POE1230-C device, the
POE
LED will illuminate to confirm correct PoE input
connection. The
CHA
light will also illuminate to confirm the battery is connected correctly and charging; this
will extinguish once the battery is fully charged.
LOA
will illuminate if there is a 12V dc load connected (max
1.5A).
M
AINTENANCE
There is no regular maintenance required for this product. If a short circuit is present on the 12V dc load
output or PoE 802.3af, the output will auto recover once the fault has been cleared. Overload from the load
or battery charging will cause the main T10.0A fuse to blow.