C

OMPLIANCE

 

 

 

 
This product meets the essential requirements of the following EU Directives: 

Low Voltage: 

2014/35/EU 

EMC: 

 

2014/30/EU 

RoHS2: 

 

2011/65/EU 

WEEE: 

 

2012/19/EU 

 

 

 

D

ISPOSAL OF 

P

RODUCT AT 

E

ND OF 

L

IFE

 

 

 

This product falls within the scope of EU Directives 2012/19/EU Waste Electrical and Electronic Equipment 
(WEEE)  and  2013/56/EU  (Battery).  At  the  end  of  life,  the  product  must  be  separated  from  the  domestic 
waste stream and disposed via an appropriate approved WEEE disposal route in accordance with all national 
and local regulations. 

 

Before disposal of the product, the standby battery must be removed and disposed separately via an 
appropriate approved battery disposal route in accordance with all national and local regulations. Package 
used batteries safely for onward transport to your supplier, collection point or disposal facility. 

 

See Specification for battery type information. The battery is marked with the crossed out wheelie bin 
symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg).  
 

For more information see: www.recyclethis.info 

 

Caution: 

Risk of explosion if battery is replaced by an incorrect type.   

Dispose of used batteries according to the battery manufacturer’s 

instructions and all local and national regulations.  

 

 

 

 

 

 

 

 

 

 

 

 

The packaging supplied with this product may be recycled. 

 Please dispose of packaging accordingly. 

 

Summary of Contents for G240xNU

Page 1: ...mode design ensures low operating costs while generating less heat The modular construction simplifies maintenance Universal mains input voltage 90 264vac Additional 0 5A to charge 2 x 12V standby bat...

Page 2: ...cuit removed under mains power only Local Indicators MAINS LED Green Mains present FAULT LED Yellow Fault present Output or battery fuse fail requires load battery to be connected loss of mains output...

Page 3: ...ly mounted within a robust enclosure having suitable means to prevent unintentional access to the module Suitable notices must be affixed to the outside of the enclosure to warn of high voltages prese...

Page 4: ...recommended total battery lead length 500mm 11 Apply mains power Check Green Mains LED is on 12 Check there is no fault indication on Yellow LED 13 Disconnect mains power Check that the batteries con...

Page 5: ...5 Technical Support 44 0 23 9269 6638 option 3 PAK200566_01B 2016 ELMDENE INTERNATIONAL LTD 128 98 42 4 60 51 84 152 106 12 4 19 13 G2402NU 157 128 7 5 128 42 4 19 60 56 5 4 135 143 12 G2403NU G2405NU...

Page 6: ...tput of the PSU fails the cause of the failure should be investigated e g short circuit load The fault should be rectified before restoring power to the PSU The fuses may need to be replaced Ensure th...

Page 7: ...7 Technical Support 44 0 23 9269 6638 option 3 PAK200566_01B 2016 ELMDENE INTERNATIONAL LTD This page has been left blank intentionally...