Model E20 Limpet Set 

 
 

The model E20 Limpet Set comprises one limpet and one keep, complete with magnet. 

 

F

EATURES

 

 

 

 

Piezo Vibration Detector 

 

Thermal Sensor 

 

Safe Proximity Sensor 

 

External Magnet Detector 

 

Supply Detection 

This unit meets the essential requirements of the following EU Directives: 
 

EN50131-1:2006 +A1:2009 

 

 

Security Grade 3 

 

 

Environmental Class II 

 

These events are signalled by the opening of a pair of normally closed relay contacts. 
 
The device is maintenance free.  

 

 

A

PPLICATIONS

 

 

 

The limpet sets are designed for the protection of safes, filing cabinets, fruit machines, etc., and 
may be fitted to any article or piece of equipment that has a ferrous exterior.  The selective 
vibration detector is designed to trigger an alarm if any attempt is made to gain access to the 
protected equipment by hammering, drilling, chiselling, etc.  The heat detector contact opens at 
a nominal temperature of 60

°

 and gives protection against attacks by thermal cutting 

techniques.  The keep reed switch, which is held in the closed circuit position by the keep 
magnet, becomes open circuit when the limpet is removed from the keep, and thus can trigger 
the alarm if any attempt is made to remove the limpet from the keep.  In this sense it acts as a 
proximity switch. The second reed switch is opened by the presence of an external magnet. This 
eliminates the possibility of an external magnet being used to override the keep magnet reed 
switch. 

 

 

 

              

 

www.acornfiresecurity.com

www.acornfiresecurity.com

Summary of Contents for E20 Limpet Set

Page 1: ...that has a ferrous exterior The selective vibration detector is designed to trigger an alarm if any attempt is made to gain access to the protected equipment by hammering drilling chiselling etc The heat detector contact opens at a nominal temperature of 60 and gives protection against attacks by thermal cutting techniques The keep reed switch which is held in the closed circuit position by the ke...

Page 2: ...an be either positive or negative triggered and should be connected to the appropriate positive or negative reset point SYSTEM OPERATION The limpet will enter its alarm condition when either of the conditions below are met Any of the reed or tamper switches are opened The internal temperature rises above 60 An impact or vibration triggers the vibration detector The alarm signal has a minimum lengt...

Page 3: ...t is intended for use by Service Personnel only There are NO USER SERVICEABLE parts inside There is no regular maintenance required of the unit other than periodic testing www acornfiresecurity com www acornfiresecurity com ...

Page 4: ...posed separately via an appropriate approved battery disposal route in accordance with all national and local regulations Package used batteries safely for onward transport to your supplier collection point or disposal facility Caution Risk of fire or explosion if bare battery wires are allowed to touch See Specification for battery type information The battery is marked with the crossed out wheel...

Reviews: