Elma 615A
side 20
Distance & spot size
As the distance (D) from the object increases, the spot size (S) of the area measured by
the unit becomes larger. The relationship between distance and spot size for each unit is
listed below. The focal point for each unit is 914mm (36”). The spot sizes indicate 90%
encircled energy.
D:S= 50:1
S
D
25mm@1250mm
1in@50in
12.5mm@625mm
0.5in@25in
Specifications
TK
Temperature range
-50 to 1370 oC(-58 ~ 2498 )
Accuracy
-50
~ 1000
℃
± 1.5% of reading
+ 3
℃
(
±5
℉
)
1000
~ 1370
℃
± 1.5% of reading
+ 2
℃
(
±3.6
℉
)
Display resolution 0.1 oC(0.1
℉
) <1000
1oC(1
℉
) >1000
Repeatability
-50
~
1370℃(-58
~
2498℉) :
± 1.5% of reading
IR
Temperature range D: S
-50 to 1200 oC(-58
℉
~ 2192
℉
) 50:1
Display resolution 0.1 oC(0.1
℉
) <1000
1
℉
>1000
Accuracy for targets:
Assumes ambient operating temperature of 23 to 25 oC (73 to 77
℉
)
-50
~ -20
℃(
-58
℉
~ -4
℉) ±4.5℃(8.1℉)
-20
~ 20
℃(
-4
℉
~ 68
℉) ±3.0℃(5.4℉)
20
℃
~500
℃(68℉
~932
℉)
±1.0% ±1.0℃(1.8℉)
500
℃
~1200
℃(932℉
~ 2192
℉)
±1.5%
Repeatability
-50
~
20℃(-58
~
68℉) : ±1.3℃(2.3℉)
20
~
1200℃(68
~
2192℉): ±0.5% or ±0.5℃(0.9℉)
Response time 150ms
Spectral response 8~14um
Emissivity Digitally adjustable from 0.10 to 1.0
Over range indication LCD will show “----”