8
1. INTRODUCTION
This
manual describes the installation of MP3040 and MP3100 control panels.
MP3000 control panels are hybrid systems that integrate wired and wireless connections using sen-
sors with video verification of alarms and home automation functions. The control panels are equipped
with a LAN connection, thus allowing remote management and operation. The control panels are
certified according to European safety standards EN50131-1, EN50131-3, EN50131-6 Grade 2.
TECHNICAL FEATURES
Max. drawn current CPU
130 mA / 14,4 V
⎓
Nominal battery charging voltage
(1)
13,8 V
⎓
Max. current supply to charge battery
0,7 A
Max. time to recharge the battery to 80%
72 ore
Low battery threshold
11,5 V
⎓
Overvoltage protection threshold
18,0 V
⎓
Maximum current for external devices:
Grade 2 - autonomy 12 hours
500 mA
Voltage nominal on teSR
(2)
14,4 V
⎓
Max. current that can be delivered by the +SR terminal
(with overload protection)
200 mA
Voltage nominal on teBUS
13,8 V
⎓
Max. current deliverable from te BUS (with overload protection)
1,1 A
Rated voltage at teV1,+V2
13,8 V
⎓
Max. current deliverable from teV1,+V2 (with overload protection)
750 mA
Max. ripple on oSR, +, +V1, +V2
100 mVpp
Max. current deliverable from PrIO terminals
40 mA
Max. current deliverable from U2 terminal
100 mA
Inputs
6
Sabotage input (24h)
1
Outputs
Relè: 1 / O.C.: 1
SR output (for self-powered devices, e.g. siren)
1
PrIO programmable input/output
2
Operating temperature range (Ambient Class II)
-10°C +40°C
Average operating relative humidity
75%
Storing temperature
-20°C +60°C
EN 50131-3 -6 conformity grade
2
EN50136 compliance
(3)
SP6, DP2
Battery housing
12 V
⎓
7,2 Ah
Dimensions (L x H x P)
338 x 2405 x 99 mm
Weight
1,25 Kg
Degree of protection
IP30 / IK06