24/44
HPA702L-LG/N
2.0 INSTALLATION
Open the siren by unscrewing the three front closing screws and remove the cage (if present) by
unscrewing the 4 screws fastening it to the bottom;
Break one of the piercing arrangements for cable passage and fasten the
siren to the wall through the provided small blocks using the provided
holes;
Perform connections and programming; use screened multipole cable for
burglar alarm systems.
Lift the micro preventing opening/removal (A) after having freed it from
the adhesive band that blocks it. The screw on which the micro rests is
factory calibrated so that the lever, when there is a cover, closes the
contact. If this is not the case (due to bearing wall irregularities), screw or
unscrew the screw as much as necessary. Close the micro again (B).
Insert the battery into the housing and connects the fastons: red wire to positive, black wire to negative.
The siren performs the initial test
(LEDs are turned on for an instant and a beep is emitted), after that
flash LEDs start blinking. Under this condition, the siren does not sound (initial block function). The
arrangement for the correct operation will occur after having applied the (BL) and TC block signals.
Drilled riser for securing
internal cage
Drilled
riser for
securing
internal
cage
Drilled riser
for securing
external
cover
Drilled
riser for
securing
external
cover
Wall
fastening
hole
Wall
fastening
hole
Cables
passage
piercing
arrangem.
Wall
fastening
hole
Drilled
riser for
securing
external
cover
Wall
fastening
hole
Drilled
riser for
securing
internal
cage
Drilled
riser for
securing
internal
cage
Cables passing
raceways
Cables
passage
piercing
arrangem.
Battery
housing
Protection
module arrang.
Summary of Contents for HPA702L/N
Page 42: ...42 44 HPA702L LG N ...
Page 43: ...43 44 HPA702L LG N ...