DS80HP8A-001F
7
ENGLISH
Outdoor Siren with flasher HP600
Component identification
1. Mounting holes
2. CC input terminal board
Not used.
3. Power switch
The switch comprises 3 positions:
BT4
: the siren is powered by a configuration with 4 alkaline batteries.
OFF
: the siren is not battery powered.
BT2
: spare configuration (do not use this position).
4. LED group 3
5. LED group 2
6. Cover fixing screw
7. LED group 1
8. Configuration dip switch
9. Learning button (LEARN)
10. Battery housing
11. Tamper switch
12. Base
Supervision
In normal operating mode, the siren transmits a supervision signal at constant
intervals. If the signal is not received, the control unit will indicate a supervision
alarm.
Dip switch Configuration
The Dip Switches are used to determine the different functions of the siren.
When the switch is moved to "ON", the switch is
ON
. When the switch is OFF it is moved to the opposite part.
The functions of each Dip Switch of the functional switch block are shown below:
SW1
Reserved
SW2
Light alarm activation (LED groups 1-2-3)
OFF position
Only during the acoustic alarm (
default
)
ON
Until the system is deactivated
SW3
SW4
Alarm time
OFF position
OFF position
3 minutes (
default
)
OFF position
ON
5 minutes
ON
OFF position
10 minutes
ON
ON
1 second (sounded TEST use)
SW5
SW6
Volume control: siren sound, exit/entrance confirmation/delay
sound
OFF position
OFF position
Reserved
OFF position
ON
Down
ON
OFF position
Medium
ON
ON
High (
default
)
SW7
Chime function (not managed on MP500/xx systems)
OFF position
Off (
default
)
ON
On
For more details see paragraph
Function overview
.
8