12/28 EL50RT 4PH 250m
- DETECTION RANGE
Max detection range is 500m (outdoor) and 250m (indoor)
- DETECTION WIDTH
The detection width can be calculated with following formula :
Width (A) = 0,025 x Length (L)
L A
60m
1,5m
100m 2,5m
200m 5,0m
- INSTALLATION HEIGHT
To detect the intruder efficiently, the sensors should
be installed within 32"~40" (80~100cm) height.
- ALIGNMENT ANGLE
The sensors can be adjusted with Horizontal ±90°
and Vertical ±10° to fit big detection range.
3.0 WIRING
- TRANSMITTER
- RECEIVER
Alarm output
Dry connect
relay output
NC./NO.
28VDC / 0.2A
Tamper output
Dry connect
Micro SW.
Output NC.
28VDC / 0.2A
Power 10.5V to 30VDC
(non-polarity)
Power
10.5V to
30VDC
(non-
polarity)
Environmental
output. Dry connect
relay output NC/NO.
28VDC/0,2A
±
10
±
90
Summary of Contents for EL50RT 4PH 250m