Installation-Programming C402-C404 

25 

 

 

9  ELECTRICAL CONNECTIONS 

 
 

C. PANEL

(-)

(+)

O

U

T

IN

+

-

+

-

SIR+

SIR-

(-)

(+)

+

-

(-)

(+)

O

U

T

IN

+

-

+

-

SIREN / VISUAL

IN

SIREN / VISUAL

IN

SIREN

OUTPUT

MODULO

SONG54

INT-SONG54

MODULE

3

3

0

0

SIREN / VISUAL

IN

OUT

(-)

(+)

SIREN

OUTPUT

C. PANEL

END OF

LINE

RESISTOR

 

 
 

Figure 9 - Examples of connections of the siren output 

 

Check, according to the siren/plate used, which of the two connection types must be adopted. 

Summary of Contents for C402

Page 1: ...1 28 Installazione MP508 DS80SC80 003D LBT80808 Installation and Programming Manual C402 C404 Conventional Fire Detection Control Panel with 2 and 4 zones GB 0051 11 ...

Page 2: ...ntact your local city office your household waste disposal service or the shop where you purchased the product The information contained in this document has been collected and controlled carefully However the company cannot be held responsible for any possible errors and omissions The company reserves the right to make at any time and without warning improvements and modifications to the products...

Page 3: ...module of the terminal board 12 3 5 SYSTEM START UP 13 3 5 1 Functional test 13 4 COMMANDS AND INDICATORS 14 4 1 KEYPAD 14 4 2 INDICATOR LIGHTS LEDS 15 5 SIGNALLING OUTPUTS AND RELAYS 16 5 1 SIREN OUTPUT 16 5 2 FAULT RELAY 16 5 3 OPTIONAL RELAY CARD 16 6 ACCESS LEVEL 17 6 1 ACCESS LEVEL 1 17 6 2 ACCESS LEVEL 2 18 7 PROGRAMMING 19 7 1 ACCESS TO PROGRAMMING 19 7 2 ZONE OPERATING MODE 19 7 2 1 Displa...

Page 4: ...B06 type The batteries are not supplied with the product 1 2 OPTIONS Optional modules MR402 auxiliary card with relay output for C402 MR404 auxiliary card with relay output for C404 1 3 CE MARKING AND ACCOMPANYING DOCUMENTATION According to the requirements of EN54 the CE marking is included and contains all required data is a trademark of URMET S p A Via Bologna 188 C 10154 Torino Italy 11 0051 C...

Page 5: ...must be installed by qualified personnel in an electrical cabinet that may contain other devices if necessary therefore it must be properly identified 2 1 3 Batteries The control panel has an internal power source with two lead sealed batteries WARNING If the batteries are replaced with inappropriate ones there is danger of explosion or fire Dispose of worn batteries by following the relevant inst...

Page 6: ...t expose the control panel to sunrays or heat sources All the components which the product is composed of have been selected for the intended use and their characteristics are guaranteed when the environmental conditions surrounding the enclosure are as specified for the 3K5 class of EN 60721 3 3 1995 2 3 SPECIAL PRECAUTIONS Strictly follow the order of the installation and connection instructions...

Page 7: ...n contacts The switching equipment must disconnect simultaneously the Line and the Neutral conductor Insert the protective plastic cover of the power supply unit terminal blocks Insert the clamp supplied with the control panel in the slot made in the plastic bottom and then anchor the power supply and earth cables to the bottom of the container by tightening the clamp Carry out the rest of the wir...

Page 8: ...terminal blocks L Connection of the power supply cable phase N Connection of the power supply cable neutral Earth connection do not remove the cable from the terminal V 26 4V negative output connection already performed do not modify V 26 4V positive output connection already performed do not modify When the wiring is finished insert the lid that covers the terminals See Figure 2 Figure 2 Closing ...

Page 9: ...ren negative output C Fault relay output Common contact NC Fault relay output Normally closed contact NO Fault relay output Normally open contact L1 Detection circuit 1 positive output L1 Detection circuit 1 negative output SH Earth connection for detection circuits cable shield L2 Detection circuit 2 positive output L2 Detection circuit 2 negative output L3 Detection circuit 3 positive output L3 ...

Page 10: ...med Inserted temporarily allows the control panel to be powered directly from the batteries when there is no mains Not armed Regular operation default configuration JP3 Armed Programming active Not armed Regular operation default configuration 3 3 BATTERIES INSTALLATION The two batteries must be installed inside the control panel and they must be connected in series observing the polarity as in fi...

Page 11: ...terminals of the electrical connector on the control panel card and the corresponding holes in the module to allow the electrical interconnection Lightly press the module to insert the plastic spacers in the H1 H2 and H3 holes of this module Check that the terminals of the electrical connector of the control panel are inserted correctly in the module holes Perform the desired electrical connection...

Page 12: ...lative alarm relay output common contact 4 Alarm zone 1 relay output normally closed contact 5 Alarm zone 1 relay output normally open contact 6 Alarm zone 1 relay output common contact 7 Alarm zone 2 relay output normally closed contact 8 Alarm zone 2 relay output normally open contact 9 Alarm zone 2 relay output common contact 10 Alarm zone 3 relay output normally closed contact 11 Alarm zone 3 ...

Page 13: ... perform the auto calibration Perform the functional test of the system and the devices 3 5 1 Functional test Verify the circuits When a device is removed the control panel must signal the opening of the circuit by activating the buzzer and turning on the fault indicator of the corresponding zone If there are fault indications check that The circuit is not in short circuit The polarity of the circ...

Page 14: ...ular operating conditions by cancelling any alarm and or fault condition No action When the control panel is in alarm condition briefly press to deactivate or re activate the siren output By pressing the key for 2 seconds the siren output is included excluded 1 During the password entry procedure number 1 is entered Includes or excludes the operation of zone 1 When the zone is excluded the corresp...

Page 15: ...tery charger inside the control panel is in a fault condition No system fault A fault has been detected on the program which runs on the control panel No fault in the siren output The siren output is in a fault condition end of line resistor is missing open line The siren output is in a fault condition output is in short circuit No exclusion or silencing is affecting the siren output The siren out...

Page 16: ...s Control panel ON without any fault event energised relay Control panel ON with at least one fault event non energised relay Control panel OFF non energised relay The silkscreen in the card is related to the non energised relay condition 5 3 OPTIONAL RELAY CARD The optional modules MR402 and MR404 are equipped with 2 or 4 outputs respectively with an SPDT form C dry contact relay that makes it po...

Page 17: ...n order to get access to the internal parts of the control panel a proper device screwdriver is required Access level 4 it can be used by personnel properly trained and authorized by the manufacturer to repair the control panel and modify its configuration In order to get access to the internal parts of the control panel and modify its configuration a proper device screwdriver and an external equi...

Page 18: ...placing the control panel in an idle condition Also the key deactivates the siren output Siren output inclusion exclusion To exclude the siren output press the key and keep it pressed until the indicator turns on To include the siren output press the key and keep it pressed until the indicator turns off The status of inclusion exclusion is saved in the non volatile memory in case the control panel...

Page 19: ...hen there is a passage in alarm of a device the control panel moves to the fire alarm condition by arming the internal buzzer and the relays of cumulative alarm and the optional module If another device of the same zone goes into the alarm condition the control panel arms the siren output and the corresponding relay of zone present in the optional module The control panel has as set up in the fact...

Page 20: ...rd of the control panel can be changed when the control panel is in the programming phase in this condition press the key until the indicator flashes and all the indicators and are on Enter the new password by pressing the keys 1 4 every time a key is pressed the indicator turns off while the corresponding indicators and display the sequence of the number key pressed After entering all the four nu...

Page 21: ...harge batteries 300mA nominal Current drawn by the control panel in normal operative conditions 80mA Max current drawn only by the card of the control panel 120mA C402 140mA C404 8 4 BATTERIES Two rechargeable lead batteries must be connected in series inside the control panel The batteries must Have the same model capacity Be of VRLA Valve Regulated Lead Acid type Have a case with UL94V 1 or bett...

Page 22: ...y contact Maximum applicable voltage 30V Maximum current 1A resistive load 8 8 DISTRIBUTION OF CONSUMPTIONS Distribution of consumptions 1 6 A max Current drawn only by the card of the control panel 120mA C402 140mA C404 Available current at the field output 550mA C402 500mA C404 Available current at the supervised siren output 550mA C402 500mA C404 Available current at the detection circuits for ...

Page 23: ...Installation Programming C402 C404 23 8 10 MECHANICAL ENVIRONMENTAL CONDITIONS Figure 7 Dimensions ...

Page 24: ...C Relative humidity 93 2 non condensing Environmental class Internal Pollution grade Grade 2 Overvoltage category CAT II In compliance with standards EN54 2 1997 A1 2006 EN54 4 1997 A1 2002 A2 2006 Conventional fire detection control panel C402 ELKRON 0051 CPR 0338 DoP n 0051 CPR 0338 Conventional fire detection control panel C404 ELKRON 0051 CPR 0337 DoP n 0051 CPR 0337 Further information is ava...

Page 25: ... IN SIREN VISUAL IN SIREN VISUAL IN SIREN OUTPUT MODULO SONG54 INT SONG54 MODULE 3300 SIREN VISUAL IN OUT SIREN OUTPUT C PANEL END OF LINE RESISTOR Figure 9 Examples of connections of the siren output Check according to the siren plate used which of the two connection types must be adopted ...

Page 26: ... Programming C402 C404 CONVENTIONAL DETECTOR LAST CONVENTIONAL DETECTOR 3300 END OF LINE RESITOR CONVENTIONAL DETECTION CIRCUIT SH DETECTION CIRCUIT C PANEL Figure 10 Connection of the devices to the detection circuit ...

Page 27: ...Installation Programming C402 C404 27 ...

Page 28: ...C404 ELKRON Tel 39 011 3986711 Fax 39 011 3986703 Milano Tel 39 02 334491 Fax 39 02 33449213 www elkron com mail to info elkron it ELKRON is a trademark of URMET S p A Via Bologna 188 C 10154 Torino TO Italy www urmet com MADE IN ITALY ...

Reviews: