UPLINK

DOWNLINK

Note

Graf

Function

0

1

2

3

4

5

6

7

ALARM 

0x0A

Heartbeat period

Blocking time

0x00

0x00

0x00

0x00

0x00

Heartbeat period

0 - 127 [x min]

Heartbeat message period

128 - 255 [(x - 127) h]

Blocking time

0 - 10 [s]

Blocking time after closing / opening of contact

Byte

0

1

2

3

Function

Bit

7

6  -  0

7

6

5

4

3

2

1

0

ALARM

First message 

fl ag: 

1 - fi rst message 

0 - others

0x0A

Reserved for future use

External 
contact: 

1 - closed

0 - opened

Reserved for 

future use

Tamper: 

1 - opened

0 - closed

Battery: 

1 - low level

0 - OK

*Version FW

*Subversion 

FW

Summary of Contents for iNELS Air AirIM-100S

Page 1: ...egory describes the Low Power Wide Area LPWA This technology is designed to provide full range coverage both inside and outside buildings energy saving and low cost operation of individual devices The Sigfox network is available to use this standard Sigfox network information The network supports bidirectional communication but with a limited number of feed backs It uses the free frequency band di...

Page 2: ...is exceeded Recommended accessories LS LED sensor is particularly suitable for power meters that support LED pulse sensing MS magnetic sensor is particularly suitable for gas meters that support magnetic sensing WS magnetic sensor for water meter it is particularly suitable for water meters that support magnetic sensing Wiring of LS MS and WS sensors brown wire white wire OUT green wire 3 Flood De...

Page 3: ...the body consult a doctor immediately Give the doctor information about the type of battery from battery case device or its manual etc to determine the chemical composition of the battery Batteries must be recycled or returned to an appropriate location e g collection container in accordance with local legal provisions power supply external or battery reset unit error MAC error MODULU start unit o...

Page 4: ...s threshold Threshold 2H 2L 0 65535 Input 2 pulses threshold Name Unit Example Counter 0 3 pulse Counter 0 0x01 Counter 1 0x02 Counter 2 0x03 Counter 3 0x04 Counter 0x01020304 16909060 pulses Function 0 1 2 3 4 5 6 7 FLOOD_SENSOR 0x03 Heartbeat period Measurement period 0x00 0x00 0x00 0x00 0x00 WINDOW_SENSOR 0x04 Heartbeat period Blocking time 0x00 0x00 0x00 0x00 0x00 Heartbeat period 0 127 x min ...

Page 5: ... mV 0 200 100 uA Threshold level for Voltage Current 1 input 2 Threshold 2L 0 100 100 mV 0 200 100 uA Threshold level for Voltage Current 2 input 2 Name Unit Example Voltage 0 1 mV Voltage 0 0x15 Voltage 1 0x7C Voltage 0x157C 5500mV Current 0 1 μA Current 0 0x2E Current 1 0xE0 Current 0x2EE0 12000μA Function 0 1 2 3 4 5 6 7 TEMPERATURE_SENSOR 0x08 Heartbeat period Measurement period Threshold diff...

Page 6: ...eat period Measurement period Threshold Temperature difference Threshold Humidity 1 Threshold Humidity 2 Threshold Temperature 1 Threshold Temperature 2 Heartbeat period 0 127 x min Heartbeat message period 128 255 x 127 h Measurement period 1 255 s Measurement period for temperature humidity Threshold Temperature difference 0 50 C Threshold difference for temperature humidity Threshold Humidity 1...

Page 7: ...t message period 128 255 x 127 h Blocking time 0 10 s Blocking time after closing opening of contact Byte 0 1 2 3 Function Bit 7 6 0 7 6 5 4 3 2 1 0 ALARM First message flag 1 first message 0 others 0x0A Reserved for future use External contact 1 closed 0 opened Reserved for future use Tamper 1 opened 0 closed Battery 1 low level 0 OK Version FW Subversion FW ...

Page 8: ...alculated under ideal conditions and may vary depending on the type of sensor connected Not included in the package Depending on network coverage Sigfix Ready Certification Certificate ID for AirIM 100S Universal Sensor P_0094_56EE_01 Power supply Battery power Battery life by frequency 1x 10 minutes 1x 60 minutes 1x 12 hours 1x 24 hours External power supply Supply voltage tolerance Standby consump...

Reviews: