Recommendations for installation
When handling a device unboxed it is important to avoid contact with
liquids. avoid unnecessary contact with the components of the device. Do
not touch the metal objects inside the unit.
Safe handling
Function
Restart
• Open the cover. Power interruption (remove the battery from the device).
• Press SET> 1min.
• Connect power (insert battery). Close the cover.
Replacing batteries
1. Using a fl at-blade screwdriver gradually slide it into one and then the other groove in
the lid and swing open the cover.
2. Remove the discharged battery and insert a new battery into the holder. Beware of
polarity. Both LEDs will fl ash 3 times (see device status indication).
3. Replace and snap the front cover.
Notice:
Only use batteries designed for this product correctly inserted in the device! Immediately replace
weak batteries with new ones. Do not use new and used batteries together. If necessary, clean the
battery and contacts prior to using. Avoid battery shorts! Do not dispose of batteries in water or
fi re. Do not dismantle batteries, do not try to charge them and protect them from extreme heating
- danger of leakage! Upon contact with acid, immediately rinse the aff ected area with a stream of
water and seek medical attention. Keep batteries out of the reach of children. If it is suspected that
the battery has been swallowed or somehow placed inside the body, consult a doctor immediately.
Give the doctor information about the type of battery (from battery case, device or its manual, etc.)
to determine the chemical composition of the battery. Batteries must be recycled or returned to an
appropriate location (e.g. collection container) in accordance with local legal provisions.
Device states
When the tamper is pressed, the LED is turned off !
Note:
R... LED red
G... LED green
* 1) Planned
power supply (external or battery),
reset unit
Connection to the network
SIM Error - cannot be loaded (SIM
card insertion and rotation check) /
or NB-IoT MODULE error
start unit ok
opening the cover
test, cancel, „long press“
temperature measurement, ...
sending / receiving data
it is necessary to disconnect the power
supply (external or battery), after 60 seconds
after the LED goes out, insert the battery
the battery may be discharged
a discharged battery or a damaged
product
Unit initialization
Start
Search for BTS * 1)
SIM ERR *1)
ERR *1)
Successful network connection * 2)
Measurement
Tamper
SET button short press (< 2s)
Measurement signaling
Communication
Communication
Other known states
Does not respond to the SET
button
The unit is still in reset
The unit does not respond even
after removal insert the battery
Indication
3 x R + G blinks
2 x fl ashes R (2xR _ 2xR _ ...)
5 x fl ashes R (repeatedly)
1 x fl ashes R
without indication
1 x fl ashes G
1 x fl ashes G
1 x fl ashes R
any LED lights
still indicates start
without indication
• Before mounting, check the range and location of the product and the antenna. Ensure
the correct location - see Warning.
• The sensor is suitable for outdoor use. Operating conditions are consistent with con-
ventional chemically non-aggressive environments.
• The recommended working position is vertical; sensor down.
• The product does not require special handling and maintenance.
When the power is connected, the transmitter sends the initial message to the server.
Any unauthorized interference with a device immediately sends the message to the
server.
Temperature, humidity and press read every 5 minutes. Report on the measured values,
the sensor sends every 30 min.