4 / 4
AirCFS-100NB
Warning
Technical parameters
Read the operating instructions before installing the device and putting it into opera-
tion. Instruction manual is designated for mounting and also for user of the device. It is
always a part of its packing. Installation and connection can be carried out only by a per-
son with adequate professional qualifi cation upon understanding this instruction man-
ual and functions of the device, and while observing all valid regulations. Trouble-free
function of the device also depends on transportation, storing and handling. In case you
notice any sign of damage, deformation, malfunction or missing part, do not install this
device and return it to its seller. It is necessary to treat this product and its parts as elec-
tronic waste after its lifetime is terminated. Before starting installation, make sure that all
wires, connected parts or terminals are de-energized. While mounting and servicing ob-
serve safety regulations, norms, directives and professional, and export regulations for
working with electrical devices. Do not touch parts of the device that are energized – life
threat. To ensure the transmission of the radio signal, make sure that the devices in the
building where the installation is installed are correctly located. Unless otherwise stated,
the devices are not intended for installation in outdoor and damp areas, they must not
be installed in metal switchboards or in plastic cabinets with metal doors - this prevents
transmission of the radio frequency signal. iNELS Air is not recommended for control-
ling life-saving instruments or for controlling hazardous devices such as pumps, heaters
without thermostat, lifts, hoists, etc. - radio frequency transmission may be overshad-
owed by obstruction, interference, transmitter battery may be discharged etc., thereby
disabling the remote control.
* Values are calculated under ideal conditions
** Not included in the package
*** Multiple frequency bands of B1 / B3 / B5 / B8 / B20 / B28
Power supply
Battery power:
Battery life by frequency *:
1x 10 minutes
1x 60 minutes
1x 12 hours
1x 24 hours
Setting
Setting:
Alarm Detection:
Battery status view:
Control
Control:
Inputs
Digital sensor:
Measuring range
Temperature sensor:
Tolerance:
Humidity sensor:
Tolerance:
Pressure gauge:
Tolerance:
Communication
Protocol:
Transmitter frequency:
Range in open space:
Transmission power (max.):
Other parameters
Working temperature:
Storage temperature:
Operating position:
Mounting:
Protection degree:
Dimension:
Weight:
1x 3.6V LS 14500 Li-SOCl
2
AA
1.9 years
3.2 years
3.6 years
3.6 years
With a message from the server,
programming cable
message to the server
only when the battery is powered by a message on the server
button SET
Tamper
Temperature, humidity, atmospheric pressure
-40 .. +85 °C
± 1.5 °C
0-100 % RH
± 3% RH
300 - 1250 hPa
± 1.7 hPa
NB-IoT
LTE Cat NB1***
Approx. 30 km (Depending on network coverage)
200 mW / 23 dBm
-30…+60°C (Pay attention to the operating
temperature of batteries)
-30…+70°C
sensor down
glue / screws
IP65
143 x 62 x 34 mm
122 g (without battery)
The company ELKO EP, as the manufacturer, is entitled to make technical modifi cations to the