2 / 2
DIM-6
Warning
Technical parameters
Function
Device is constructed for connection in 1-phase main AC and must be installed according
to norms valid in the state of application. Connection according to the details in this
direction. Installation, connection, setting and servicing should be installed by qualifi ed
electrician staff only, who has learnt these instruction and functions of the device. This
device contains protection against overvoltage peaks and disturbancies in supply. For
correct function of the protection of this device there must be suitable protections of
higher degree (A, B, C) installed in front of them. According to standards elimination of
disturbancies must be ensured. Before installation the main switch must be in position
“OFF” and the device should be de-energized. Don´t install the device to sources of
excessive electro-magnetic interference. By correct installation ensure ideal air circulation
so in case of permanent operation and higher ambient temperature the maximal operating
temperature of the device is not exceeded. For installation and setting use screw-driver
cca 2 mm. The device is fully-electronic - installation should be carried out according to
this fact. Non-problematic function depends also on the way of transportation, storing
and handling. In case of any signs of destruction, deformation, non-function or missing
part, don´t install and claim at your seller. After the product exceeds lifetime, it should
be removed and placed in protected dump. Important advice and warning: Dimmer is
designated for managing brightness of el. bulbs, in case of low-voltage halogen lights with
separating ferromagnetic transformer or electronic transformer.
Warning: by signals HDO and similar signals that are distributed in the main, can create
disturbances of dimmer. Disturbance is active only for the period of signal transmission.
Supply terminals:
Supply voltage:
Burden (unloaded):
Max. dissipated power:
Tolerance of supply voltage:
Max. output power:
Module extendable:
Galvanic separation of bus
and power output:
Isulating voltage between
outputs and inner circuits:
Control - button type
Control voltage:
Control terminals:
Power of control input:
Length of control impulse:
Recovery time:
Connection of glow lamps:
Control 0(1)-10V
Control terminals:
Control voltage:
Min. current of control input:
BUS control
Control terminals:
bus voltage:
Current of control input:
Indication of data transmission:
Output
Contactless:
Rated current:
Resistive load:
Inductive load:
Capacitive load:
Indication of output state:
Other data
Operating temperature:
Storing temperature:
Operating position:
Mounting:
Protection degree:
Purpose of control device:
Construction of control device:
Char. of automatic operation:
Heat and fi re resistance cat.:
Anti-stroke category
(immunity):
Rated impulse voltage:
Overvoltage category:
Pollution level:
Profi le of connecting wires (mm
2
):
- output part:
- control part:
Dimensions:
Weight:
Applying standards:
L, N
AC 230 V / 50 Hz
max. 4 VA / 3.2 W
6 W
-15 %; +10 %
max. 2 000 VA
to 10 000 VA
yes
3.75 kV, SELV according to EN 60950
AC 12 - 240 V
S - S, galvanically separated
AC 0.53 VA (AC 230 V), AC 0.025 - 0.2 VA (AC 12-240 V)
min. 25 ms / max. unlimited
max. 150 ms
no
0(1) - 10 V, GND
0 - 10 V or 1 - 10 V
1 mA
BUS+, BUS-
27 V DC
5 mA
yellow LED
4x MOSFET
10 A
2 000 VA*
2 000 VA*
2 000 VA*
yellow LED, according to load type
-20.. +35 °C
-30.. +70 °C
vertical
DIN rail EN 60715
IP40 from front panel
operative control device
individual control device
1.B.E
FR-0
class 2
2.5 kV
III.
2
max.1x2.5, max. 2x1.5 / with sleeve max. 1x1.5 (AWG 12)
max.1x2.5, max. 2x1.5 / with sleeve max. 1x2.5 (AWG 12)
90 x 105 x 65 mm (3.5˝ x 4.1˝ x 2.6˝)
392 g (13.8 oz.)
EN 60669-2-1, EN 61010, EN 55014
This device is designated for switching and dimming of lightning, light bulbs and halogen
lamps with wound or electronical transformator up to 2 000 VA in the range of luminance
intensity 0-100%. Capaticy of attachable load could be increase with additional modul up
to 10 000 VA. Switching and dimming of attached output load is controlled with several
modes - types of control, which are chosen with button PROG. Modes are to be switched
in circle after you press PROG button and analogically indicated on the front panel with
one of four green LED diods.
Modes of control dimmer DIM-6:
- button
on the front panel - in mode
is possible to control dimmer output and
regulate luminance setting 0-100% (short button press turn on/off the light, longer
press > 0.5s - allows slight luminance setting).
- external button on terminals S, S - this control input of device is galvanicaly separated
from inside device circuits, operation switching voltage by external button can be in the
range AC/DC 12-240V, polarity voltage doesn´t metter. Output controlling is identical as
control by button
on the fornt panel (short button press turn on/off the light, longer
press > 0.5s - allows slight luminance setting).
- control signal 0-10 V or 1-10V - into this input is possible connect the external converter
with output 0-10V or 1-10V, where 0 V (or 1 V) on the terminal 0(1)-10 V is equal to 0%
luminance intensity and 10 V is equal to 100% luminance intencity. This voltage must be
related to terminal GND.
- external potenciometr 50k - during the service of an internal supplier (te 10 V),
is possible to use an external potenciometr, by connecting it with terminal 0(1)-10 V and
GND, see the picture of connection options. With this potenciometer is possible to control
an output of dimmer in the range of luminance intencity 0-100%.
- iNELS, with the help of conductor bar BUS - dimmer is possible to use as a component of
conductor bar in system iNELS. Operating of dimmer is controlled by central conductor
bar system iNELS.
It’s not possible to combine individual types of dimmer controllers.
Attention - before setting the mode of dimmer control, is necessary to set up the type of
connecting load, with the wire jumper on terminals RC or RL. If the type of connecting load
is not set up, LED diods RC and RL are fl ashing in turns and switching, dimming of load on
output is not possible. If the type of load is set up incorrectly than is connected on output,
that cause a risk of demage or destruction of operating output of device!!!
The dimmer has multiple current terminals, for easier installation of this device. It’s not
possible to use these terminals as a conductor bar for distribution of current in installation.
Dimmer is equipped with heat and overcurrent protection - signalized by red LED diod on
the front panel. Flashing LED diod signalize heat overload (overheating) inside the device.
Dimmer is also equiped with electronic overcurrent protection, which will be activated in
the case of device overload or short circuit of output with N conductor - output will be
switched off .
Supply of device (potencial L) must be protected with circuit breaker component, which
has to be accordant with load connected to device by fast fuse.
* Warning: it is not allowed to connect inductive and capacitive loads in the same time.