Page 3
1000001734 (Rev. K- 04/18)
EZWSR*1C, *2C LZWSR*1C, *2C
17
7
/8
"
45
4m
m
7"
17
8m
m
7"
17
8m
m
7/
16
" X
3
/4
"
11
m
m
X
1
9m
m
OB
RO
UN
D
HO
LE
S
(6
)
15
"
38
1m
m
2
7/
8"
73
m
m
2"
51
m
m
51
9
/16
"
13
10
m
m
34
5
/16
"
87
2m
m
24
1
/2
"
62
2m
m
22
1
5/
16
"
58
3m
m
19
7
/16
"
49
4m
m
21
7
/8
"
55
6m
m
19
"
48
3m
m
28
1
3/
16
"
73
2m
m
2"
51
m
m
17
7
/16
"
44
3m
m
13
1
5/
16
"
35
4m
m
7"
17
8m
m
7"
17
8m
m
5
3/
4"
14
6m
m
2"
51
m
m
FI
NI
SH
ED
F
LO
OR
6
3/
8"
16
2m
m
6
3/
8"
16
2m
m
‰
‰
2"
51
m
m
7/
8"
22
m
m
E
E
A
(A
LT
. L
OC
AT
IO
N)
F
D
PR
EF
ER
RE
D
LO
CA
TI
ON
D
(A
LT
. L
OC
AT
IO
N)
9/
32
" Ø
7m
m
Ø
HO
LE
S
12
B
A
PR
EF
ER
RE
D
LO
CA
TI
ON
12
1
/2
"
31
8m
m
3"
77
m
m
1
7/
16
"
37
m
m
C
8
1/1
6"
20
5m
m
18
7
/8
"
47
9m
m
3
9/
16
"
90
m
m
19
"
48
3m
m
HA
NG
ER
B
RA
CK
ET
32
7
/8
"
83
5m
m
OR
IF
IC
E
HE
IG
HT
31
5
/1
6"
79
6m
m
RI
M
HE
IG
HT
38
3
/8
"
97
5m
m
OR
IF
IC
E
HE
IG
HT
36
1
3/
16
"
93
6m
m
RI
M
HE
IG
HT
OP
TI
ON
AL
F
IL
TE
R
FI
LT
ER
6
3/
8"
16
2m
m
6
3/
8"
16
2m
m
18
3
/8
"
46
7m
m
27
"
68
6m
m
AD
A
RE
QU
IR
EM
EN
T
F
3
7/
8"
98
m
m
AC
TI
VA
TI
ON
S
EN
SO
R
38
1
/2
"
97
9m
m
LEGEND/LEYENDA/LÉGENDE A = RECOMMENDED W
ATER SUPPL
Y LOCA
TION 3/8 O.D. UNPLA
TED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY
OTHERS) 3 IN. (76
mm
)
MAXIMUM OUT FROM W
ALL
La UBICACION 3/8 O RECOMENDADA
de
ABASTECIMIENT
O DE
AGUA. D. El
TUBO del COBRE de UNPLA
TED CONECT
A
TALONARIO CON
AP
AGO
(POR OTROS) 3 en. (76 Mm) el MAXIMO FUERA
DE P
ARED
L’O.D de 3/8 d’EMPLACEMENT
DE PROVISION D’EAU RECOMMANDE. LE
TUBE DE CUIVRE DE UNPLA
TED CONNECTE STUB
AVEC ETEINT
(P
AR
LES
AUTRES) 3 dans. (76 mm) le MAXIMUM HORS DU MUR
B = RECOMMENDED LOCA
TION FOR W
ASTE OUTLET 1-1/2” O.D. DRAIN STUB 2 IN. OUT FROM W
ALL
UBICACIÓN RECOMENDADA
P
ARA
EL
DRENAJE DE SALIDA
DE
AGUA, DE 1-1/2” DE DIÁMETRO.
El
TALONARIO 2 FUERA
DE P
ARED
EMPLACEMENT
RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/2” DE SOR
TIE D’EAU.
STUB 2 HORS DU MUR
C = 1-1/2” TRAP
NOT FURNISHED
PURGADOR DE 1-1/2” NO PROPORCIONADO SIPHON 1-1/2” NON FOURNI
D = ELECTRICAL
SUPPL
Y (3) WIRE RECESSED BOX**
CAJA
RECESIV
A DE
ALAMBRES (3) DE SUMINISTRO ELÉCTRICO
BOÎTE ENCASTRÉE D’ALIMENT
ATION ÉLECTRIQUE (3) FILS
LEGEND/LEYENDA/LÉGENDE D = ELECTRICAL
SUPPL
Y (3) WIRE RECESSED BOX**
CAJA
RECESIV
A DE
ALAMBRES (3) DE SUMINISTRO ELÉCTRICO
BOÎTE ENCASTRÉE D’ALIMENT
ATION ÉLECTRIQUE (3) FILS
E = INSURE PROPER VENTILA
TION BY
MAINT
AINING 6” (152
mm
) (MIN.) CLEARANCE FROM CABINET LOUVERS T
O W
ALL.
ASEGURE UNA
VENTILACIÓN
ADECUADA
MANTENIENDO UN ESP
ACIO E 6” (152
mm
) (MÍN.) DE HOLGURA
ENTRE LA
REJILLA
DE VENTILACIÓN DEL
MUEBLE
Y LA
P
ARED.
ASSUREZ-VOUS UNE BONNE VENTILA
TION EN GARDANT
6” (152
mm
) (MIN.) ENTRE LES ÉVENTS DE L
’ENCEINTE ET
LE MUR.
F = 7/16 BOL
T HOLES FOR F
ASTENING UNIT T
O W
ALL
AGUJEROS DE LAS
TUERCAS DE 7/16 P
ARA
SUJET
AR LA
UNIDAD
A LA
P
ARED
TROUS D’ÉCROUS 7/16 POUR FIXER L
’APP
AREIL
AU MUR
**NEW INST
ALLA
TIONS MUST USE GROUND F
AUL
T CIRCUIT INTERRUPTER (GFCI)
**
Las nuevas instalaciones deben utilizar el interruptor de circuito de tierra de la avería (GFCI)
**
Les nouvelles installations doivent employer l’interrupteur de circuit moulu de défaut (GFCI)
REDUCE HEIGHT BY
3 INCHES FOR INST
ALLA
TION OF CHILDREN’S
ADA
COOLER
ST
ANDARD ROUGH-IN FOR LEFT
-HAND HIGH, BOTTLE FILLER LOW MODELS
Fig. 2