98518C  (Rev. B - 2/10)

LZWSR*1A

CHANGING THE FILTER AND RESETTING THE VISUAL FILTER MONITOR

The electronic sensor includes LED filter status indicators that are factory preset to monitor filter life. The sensor monitors the “ON” time
of the water valve solenoid and keeps track of total time water is dispensed.
There are (3) LED’s that indicate the following:

Green: LED (Good) indicates that the filter is operating within 0% - 80% of its life.
Yellow: LED indicates that the filter is operating within 80% - 100% of its life.
Red: LED (Replace) indicates that the filter needs to be replaced since it has reached end of filter life.

TO CHANGE THE FILTER:

1)

Remove the lower front panel of the watercooler by removing the four (4) screws

2)

Turn inlet water valve off.

3)

Open bubbler to relieve pressure build-up in the system.

4)

Remove filter from head by rotating filter counterclockwise.

5)

Remove new filter from carton, remove protective cap; cap may be placed on old filter to reduce the chance of water spilling from
filter housing.

6)

Attach filter to filter head by firmly inserting into head and rotating filter clockwise.

7)

Turn on water supply and hold open the bubbler on cooler until approximately 1 gallon of water is dispensed. This flushing
procedure purges air and fine carbon particles from the filter.

TO RESET THE FILTER MONITOR:
1)

In order to reset the visual filter monitor status LED’s, you must remove the top cover of the bottle filler. Remove the  two (2) screws
with  a 5/32 allen wrench holding top cover to Bottle Filler. Remove top cover. Do not discard mounting screws, they will be needed
to reinstall the top cover

2)

With your finger, reach inside the opening and depress the program button located behind  the LCD display outside of the electron-
ics cover for approximately 2 seconds until the display changes then release.  The display will change and scroll through three
messages:

“RST FLTR” – Reset Filter Status LED
“RST BCNT” – Reset Bottle Count
“RNG SET” – Range Set for IR Sensor

If the program button is not pushed again the display will scroll through the three messages above for three cycles and then default
back to bottle count and be back in run mode.

3)

When the display  changes  to “RST FLTR”, depress the button again. The display will change to show “FLT =”. Depress the button
again and the display will show  “FLTR =0”

4)

The Green LED should be illuminated indicating that the visual filter monitor has been reset. Reinstall the top cover.

SETTING THE CONTROL BOARD – SETTING RANGE OF THE IR SENSOR

1)

In order to access the programming button, you must remove the top cover of the bottle filler. Remove the  two (2) screws with a

       5/32” allen wrench holding top cover to Bottle Filler. Remove top cover. Do not discard mounting screws, they will be needed to

reinstall the top cover

2)

With your finger, reach inside the opening and depress the program button located behind  the LCD display outside of the

      electronics cover for approximately 2 seconds until the display changes then release.  The display will change and scroll through

three messages:

“RST FLTR” – Reset Filter Status LED
“RST BCNT” – Reset Bottle Count
“RNG SET” – Range Set for IR Sensor

If the program button is not pushed again the display will scroll through the three messages above for three cycles and then default
back to bottle count and be back in run mode.

1)

To set the RANGE of IR Sensor:  when display shows “RNG SET” push program button once the display will show current value (can
be 1 – 10) i.e. “RNG = 3”.

2)

Once display shows current value push the program button to scroll through value of 1 – 10.  Select the desired range setting.

3)

Once range is selected allow approximately 4 seconds to pass and then the display will go back to bottle counter and be in run
mode.

4)

Test bottle filler by placing bottle or hand in front of sensor to make sure water is dispensed.

  SETTING THE CONTROL BOARD – RESETTING BOTTLE COUNT

1)

In order to access the programming button, you must remove the top cover of the bottle filler. Remove the  two (2) screws with  a 5/
32 allen wrench holding top cover to Bottle Filler. Remove top cover. Do not discard mounting screws, they will be needed to
reinstall the top cover

2)

With your finger, reach inside the opening and depress the program button located behind  the LCD display outside of the electron-
ics cover for approximately 2  seconds until the display changes then release.  The display will change and scroll through three
messages:

“RST FLTR” – Reset Filter Status LED
“RST BCNT” – Reset Bottle Count
“RNG SET” – Range Set for IR Sensor

If the program button is not pushed again the display will scroll through the three messages above for three cycles and then default
back run mode which display bottle count.

3)

To reset the BOTTLE COUNTER:  when display shows “RST BCNT” push program button once the display will show current value
i.e. “BC0033183”.

4)

Once display shows current value push the program button once more to reset back to 0.  The display will show BTLCT = 0 for
approximately 2 seconds and then return to run mode showing 00000000 bottles.

5)

To test bottle counter, you can place bottle or hand in front of sensor for approx 5 seconds to see bottle counter count 00000001.
(This is based on filling a 16 oz bottle)

Summary of Contents for LZWSRK -EZH2O

Page 1: ...TELEPHONE COMPUTERS ETC TO WATER LINES IS ACOMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCURAWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICALFEEDBACK INTOAFOUNTAIN CREATINGAN ELEC TROLYSIS WHICH CAUSESAMETALLIC TASTE ORAN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION ISAVOIDABLE BY USING THE PROPER MATERIALSAS INDICATED ANY DRAIN FITTINGS PROVIDED BY THE INST...

Page 2: ... supply pressure will ever exceed 100 psi install a pressure regulator to limit the inlet pressure to the filter to 100 psi or below DO NOT ATTACH HOT WATER LINE TO FILTER To make connections on the filter head loosen locknut Push the tube end past both o rings to a positive stop in the filter head recess approx 1 locknut may have to be backed out a little more Screw the locknut hand tight to seal...

Page 3: ...to the open terminal of the solenoid valve to the unit that the basin hole was punched in for the Bottle Filling Station Attach the yellow wire supplied on to the open terminal of the solenoid valve of the other unit 8 Reassemble Basin Assembly back on to unit Connect the bubbler water line to the outlet side of the solenoid valve F See Fig 8 be sure to reconnect the black wire from the solenoid v...

Page 4: ... Tee 3 8 To 1 4 Union 3 8 Water Line from Bottle Filling Unit H H R H Refrig unit L H Non Refrig unit Filter Assembly 1 4 Union Fig 7 EZ Non Pressurized Plumbing Diagram Evaporator Bubbler Solenoid Valve Water Inlet B C A EZ Plumbing Diagram after Filter Installation Pressurization Modifications Bubbler Filter Assembly 3 8 Water Line from Bottle Filling Unit Evaporator Solenoid Valve 1 4 Tee 3 8 T...

Page 5: ...ed tabs protuding from the wall mounting plate installed on wall See Fig 11 Make sure rubber Drain Mat is installed properly on bottom of Bottle filler See Cover Illustration 9 Once Bottle Filler is installed on wall plate tabs drain mat water line wire s and power cord are installed properly push top of Bottle Filler toward wall and line up top cover two 2 holes 10 Reinstall Top Cover on Bottle F...

Page 6: ...NSOR 1 In order to access the programming button you must remove the top cover of the bottle filler Remove the two 2 screws with a 5 32 allen wrench holding top cover to Bottle Filler Remove top cover Do not discard mounting screws they will be needed to reinstall the top cover 2 With your finger reach inside the opening and depress the program button located behind the LCD display outside of the ...

Page 7: ...wn in Fig 12 2 Drill a 3 16 dia hole at location B shown in Fig 12 3 Remove Filter bracket from filter assembly and reinstall as shown in Fig 13 Be sure the 3 8 water inlet is facing out 4 Install plastic bushing supplied as shown into 1 3 8 hole bushing must be used so waterlines will not be cut by sharp edges of base plate 5 Install filter assembly to bottom of cooler as shown in Fig 13 with 2 8...

Page 8: ...8 18 x 75 PH Fitting Superseal 3 8 10 mm Fitting Superseal 1 4 6 mm Filter Assy Elbow 3 8 10mm Bracket DESCRIPCIÓN DESCRIPTION Ensamblado de la Cabeza del Filtro Tornillo 8 18 x 75 PH Accesorio Supersello 3 8 10mm Accesorio Supersello 1 4 6 mm Ensamblado del Filtro Codo 3 8 10 mm Fijador Ens de tête de filtre Vis 8 18 x 75 hp Raccord Superseal 3 8 10mm Raccord Superseal 1 4 6mm Ens filtre Coude 3 ...

Reviews: