LZWSR*1A

7/16” BOLT  HOLES FOR
FASTENING UNIT TO WALL

UNIT CENTER LINE

TOP COVER

MOUNTING

SCREWS

Fig. 9

BOTTLE  FILLER  INSTALLATION

1)  Remove two (2) mounting screws with 5/32” allen wrench holding top cover to  Bottle Filler (See FIG. 10). Remove top cover. Note do not discard mounting

screws, they will be needed to reinstall top cover..

2)  Remove wall mounting plate from Bottle Filler. Place Wall plate against wall on top of EZ basin.  Center the wall plate side to side with the EZ basin. Mark

the six (6) mounting holes with a pencil (See FIG. 9).

3)  Remove wall mounting plate from wall. NOTE: Mounting plate MUST be supported securely. Add fixture support carrier if wall will not provide adequate

support.

4)  Install wall mounting plate to wall using six (6) 7/16” obround mounting holes (mounting bolts not included) (See FIG. 9). Use appropriate fasteners for

your wall type.

5)  Place Drain Mat into position on the bottom of the Bottle Filler Unit.
6)  For Single Model installations: Attach the purple wire from cooler to the purple wire on the back of the unit, (Note yellow wire is not used).
6a)  For Two-Level model installations: Attach the purple and yellow wires from coolers to the purple and yellow wires on the back of the unit, purple to
    purple, yellow to yellow.
7)  Remove 3/8” to 1/4” reducing union from end of waterline, (do not throw away it will be needed later). Lay Bottle Filler on water cooler basin and cut

insulation from tube even with bottom of unit,  remove this insulation from 3/8” tube, but do not discard. Fish the power cord, and waterline through the
hole on top of water cooler created from the “Water Cooler Preparation” section. NOTE: To prevent scratching the basin place a towel or soft cloth over the
entire basin when working above it.

8)  With the power cord and waterline through hole on top of water cooler place Bottle Filler on the three (3) angled tabs protuding from the wall mounting

plate, installed on wall (See Fig. 11).  Make sure rubber Drain Mat is installed properly on bottom of Bottle filler (See Cover Illustration).

9)  Once Bottle Filler is installed on wall plate tabs, drain mat, water line, wire(s) and power cord are installed properly, push top of Bottle Filler toward wall
     and line up top cover two (2) holes.
10) Reinstall Top Cover on Bottle Filler (See FIG. 10)  with two mounting screws from step 1 above. Caution do not over tighten screws.
11) Install remaining tube insulation on to water line from bottle filler, connect Bottle Filler waterline inside to the water cooler by connecting the 3/8” water
     line with the 3/8” to 1/4” union and short piece of poly tube that was previously installed to the tee. (See Fig. 8 or 8A).
12) Install filter cartridge, remove filter from carton, remove protective cap, attach filter to filter head by firmly inserting into head and rotating filter
     clockwise. NOTE: If existing plumbing roughin locations (Drain, Water In, Electric Supply) do not allow the filter to be mounted inside the cooler

cabinet the filter can be installed horizontally below the unit see page 7.  A retrofit kit is available to mount the filter beneath the cooler.

13) Turn water supply on and inspect for leaks. Fix all leaks before continuing.
14) Once unit has been inspected for leaks and any leaks found corrected plug Bottle Filler and LZ unit into wall. Be sure to reinstall fuse to the circuit
     or switch the circuit breaker back to the “ON” position.
15) Once power is applied to Bottle Filler, the GREEN LED light should illuminate showing good filter status along with the LCD Bottle Counter.
16) Verify proper dispensing by placing cup, hand, or any opaque object infront of sensor area and verify water dispenses.  Note: the first intitial

dispenses  might have air in line which may cause a sputter.  This will be eliminated once all air is purged from the line.

17) Once unit tests out, install Lower Panel back on EZ water cooler(s).  Units are now ready for use.

Fig. 10

Fig. 11

WALL MOUNTING PLATE

BOTTLE FILLING UNIT

Summary of Contents for LZWSRK -EZH2O

Page 1: ...TELEPHONE COMPUTERS ETC TO WATER LINES IS ACOMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCURAWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICALFEEDBACK INTOAFOUNTAIN CREATINGAN ELEC TROLYSIS WHICH CAUSESAMETALLIC TASTE ORAN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION ISAVOIDABLE BY USING THE PROPER MATERIALSAS INDICATED ANY DRAIN FITTINGS PROVIDED BY THE INST...

Page 2: ... supply pressure will ever exceed 100 psi install a pressure regulator to limit the inlet pressure to the filter to 100 psi or below DO NOT ATTACH HOT WATER LINE TO FILTER To make connections on the filter head loosen locknut Push the tube end past both o rings to a positive stop in the filter head recess approx 1 locknut may have to be backed out a little more Screw the locknut hand tight to seal...

Page 3: ...to the open terminal of the solenoid valve to the unit that the basin hole was punched in for the Bottle Filling Station Attach the yellow wire supplied on to the open terminal of the solenoid valve of the other unit 8 Reassemble Basin Assembly back on to unit Connect the bubbler water line to the outlet side of the solenoid valve F See Fig 8 be sure to reconnect the black wire from the solenoid v...

Page 4: ... Tee 3 8 To 1 4 Union 3 8 Water Line from Bottle Filling Unit H H R H Refrig unit L H Non Refrig unit Filter Assembly 1 4 Union Fig 7 EZ Non Pressurized Plumbing Diagram Evaporator Bubbler Solenoid Valve Water Inlet B C A EZ Plumbing Diagram after Filter Installation Pressurization Modifications Bubbler Filter Assembly 3 8 Water Line from Bottle Filling Unit Evaporator Solenoid Valve 1 4 Tee 3 8 T...

Page 5: ...ed tabs protuding from the wall mounting plate installed on wall See Fig 11 Make sure rubber Drain Mat is installed properly on bottom of Bottle filler See Cover Illustration 9 Once Bottle Filler is installed on wall plate tabs drain mat water line wire s and power cord are installed properly push top of Bottle Filler toward wall and line up top cover two 2 holes 10 Reinstall Top Cover on Bottle F...

Page 6: ...NSOR 1 In order to access the programming button you must remove the top cover of the bottle filler Remove the two 2 screws with a 5 32 allen wrench holding top cover to Bottle Filler Remove top cover Do not discard mounting screws they will be needed to reinstall the top cover 2 With your finger reach inside the opening and depress the program button located behind the LCD display outside of the ...

Page 7: ...wn in Fig 12 2 Drill a 3 16 dia hole at location B shown in Fig 12 3 Remove Filter bracket from filter assembly and reinstall as shown in Fig 13 Be sure the 3 8 water inlet is facing out 4 Install plastic bushing supplied as shown into 1 3 8 hole bushing must be used so waterlines will not be cut by sharp edges of base plate 5 Install filter assembly to bottom of cooler as shown in Fig 13 with 2 8...

Page 8: ...8 18 x 75 PH Fitting Superseal 3 8 10 mm Fitting Superseal 1 4 6 mm Filter Assy Elbow 3 8 10mm Bracket DESCRIPCIÓN DESCRIPTION Ensamblado de la Cabeza del Filtro Tornillo 8 18 x 75 PH Accesorio Supersello 3 8 10mm Accesorio Supersello 1 4 6 mm Ensamblado del Filtro Codo 3 8 10 mm Fijador Ens de tête de filtre Vis 8 18 x 75 hp Raccord Superseal 3 8 10mm Raccord Superseal 1 4 6mm Ens filtre Coude 3 ...

Reviews: