Page 3
98518C (Rev. B - 2/10)
LZWSR*1A
Fig. 3
SCREWS
SCREWS
BASIN ASSEMBLY
Fig. 4
Basin Assembly Removal
EWF3000 Filter Location
FILTER ASSEMBLY
SCREWS
BASIN ASSEMBLY PREPARATION
1) Center punch 1/2” hole location on basin prior to drilling the hole in top of cooler basin using an adequete drill and 1/2” drill bit capable of drilling
through stainless steel (See FIG. 2).
2) Locate 1-3/8” knockout punch tool (provided). Unscrew the top half from the bottom half of the tool.
3) With one hand holding the bottom half, and the other hand holding the top half of the punch, insert the top half bolt through the 1/2” hole in basin,
then reach inside the basin assembly underneath the cooler basin with the bottom half and thread it on to the top half bolt. Tighten bottom half on punch
until finger tight.
4) Using 3/4” wrench or crecent wrench tighten the bolt on top half of punch until basin gives way creating the larger hole. Note tool will turn hard.
5) Once hole is made tool may be discarded.
6) Locate plastic bushing (provided) and place in basin hole by pushing into hole until it snaps into place. This bushing protects the water line, wire(s),
and power cord from sharp edge of basin. This part must be used.
7) For Single Model installations: Attach the purple wire (supplied), on to the open terminal of the solenoid valve.
7a) For Two-Level Model installations: Attach the purple wire (supplied), on to the open terminal of the solenoid valve to the unit that the basin hole
was punched in for the Bottle Filling Station. Attach the yellow wire (supplied), on to the open terminal of the solenoid valve of the other unit.
8) Reassemble Basin Assembly back on to unit. Connect the bubbler water line to the outlet side of the solenoid valve “F” (See Fig.8), be sure to
reconnect the black wire from the solenoid valve back to the purple or yellow piggyback terminal on the solenoid valve. and the other black wire back to
the cold control or power cord (non-refrigerated unit), fish the purple and/or yellow wire(s) up through basin hole and reattach drain to the trap.
Retighten the 4 screws two per side see Fig. 3.
STANDARD TWO-LEVEL MODELS
After completing instructions 1 thru 8 from above on the non-refrigerated side. Install filter head assembly per previous installation instructions and
reinstall basin assembly to the non-refrigerated side, re-attach wiring, bubbler tube to solenoid valve and reinstall the two level cover plate to the left
sideof the unit. Reinstall non-refrigerated unit to wall and reinstall drain.
TWO-LEVEL REVERSED MODELS
After completing instructions 1 thru 8 from above on the refrigerated side. Install filter head assembly per previous installation instructions and reinstall
basin assembly to the non-refrigerated side, re-attach wiring, bubbler tube to solenoid valve and reinstall the two level cover plate to the left side of the
unit. Reinstall non-refrigerated unit to wall and reinstall drain.
Fig. 5
Note: Screw the locknut hand tight to seal
Fig. 6