background image

Page 1

98518C  (Rev. B - 2/10)

LZWSR*1A

LZWSRK -EZH2O    R

ETRO

-F

IT

 B

OTTLE

 F

ILLING 

U

NIT

INSTALLATION, CARE & USE MANUAL

T M

LZWSR Bottle Fillers are among the easiest to install on the market today. To
insure you install these models easily and correctly,  PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK
YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND
OTHER APPLICABLE CODES. After installation, leave these instructions with the
Fountain for future reference.

IMPORTANT

THIS IS AN INDOOR APPLICATION ONLY.
ALL SERVICE TO BE PERFORMED BY AN

 AUTHORIZED SERVICE PERSON.

IMPORTANT! INSTALLER PLEASE NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE
BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELEC-
TROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER.
THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS
PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN
FROM THE BUILDING PLUMBING SYSTEM. WE SUGGEST THAT THE BOTTLE FILLING STATION AND WATER
COOLER BE PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER (GFCI).

INSTALLER

TOOLS REQUIRED

BUT NOT PROVIDED:

SAFETY GLASSES
GLOVES
1-3/8” HOLE PUNCH (PROVIDED)
1/2” DRILL BIT
ELECTRIC DRILL
3/4” WRENCH OR CRECENT WRENCH
5/16” NUT DRIVER
UTILITY KNIFE
TAPE MEASURE
PENCIL
CENTER PUNCH
1/2” SOCKET & RATCHET WRENCH
5/32” ALLEN WRENCH

Summary of Contents for LZWSRK -EZH2O

Page 1: ...TELEPHONE COMPUTERS ETC TO WATER LINES IS ACOMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCURAWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICALFEEDBACK INTOAFOUNTAIN CREATINGAN ELEC TROLYSIS WHICH CAUSESAMETALLIC TASTE ORAN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION ISAVOIDABLE BY USING THE PROPER MATERIALSAS INDICATED ANY DRAIN FITTINGS PROVIDED BY THE INST...

Page 2: ... supply pressure will ever exceed 100 psi install a pressure regulator to limit the inlet pressure to the filter to 100 psi or below DO NOT ATTACH HOT WATER LINE TO FILTER To make connections on the filter head loosen locknut Push the tube end past both o rings to a positive stop in the filter head recess approx 1 locknut may have to be backed out a little more Screw the locknut hand tight to seal...

Page 3: ...to the open terminal of the solenoid valve to the unit that the basin hole was punched in for the Bottle Filling Station Attach the yellow wire supplied on to the open terminal of the solenoid valve of the other unit 8 Reassemble Basin Assembly back on to unit Connect the bubbler water line to the outlet side of the solenoid valve F See Fig 8 be sure to reconnect the black wire from the solenoid v...

Page 4: ... Tee 3 8 To 1 4 Union 3 8 Water Line from Bottle Filling Unit H H R H Refrig unit L H Non Refrig unit Filter Assembly 1 4 Union Fig 7 EZ Non Pressurized Plumbing Diagram Evaporator Bubbler Solenoid Valve Water Inlet B C A EZ Plumbing Diagram after Filter Installation Pressurization Modifications Bubbler Filter Assembly 3 8 Water Line from Bottle Filling Unit Evaporator Solenoid Valve 1 4 Tee 3 8 T...

Page 5: ...ed tabs protuding from the wall mounting plate installed on wall See Fig 11 Make sure rubber Drain Mat is installed properly on bottom of Bottle filler See Cover Illustration 9 Once Bottle Filler is installed on wall plate tabs drain mat water line wire s and power cord are installed properly push top of Bottle Filler toward wall and line up top cover two 2 holes 10 Reinstall Top Cover on Bottle F...

Page 6: ...NSOR 1 In order to access the programming button you must remove the top cover of the bottle filler Remove the two 2 screws with a 5 32 allen wrench holding top cover to Bottle Filler Remove top cover Do not discard mounting screws they will be needed to reinstall the top cover 2 With your finger reach inside the opening and depress the program button located behind the LCD display outside of the ...

Page 7: ...wn in Fig 12 2 Drill a 3 16 dia hole at location B shown in Fig 12 3 Remove Filter bracket from filter assembly and reinstall as shown in Fig 13 Be sure the 3 8 water inlet is facing out 4 Install plastic bushing supplied as shown into 1 3 8 hole bushing must be used so waterlines will not be cut by sharp edges of base plate 5 Install filter assembly to bottom of cooler as shown in Fig 13 with 2 8...

Page 8: ...8 18 x 75 PH Fitting Superseal 3 8 10 mm Fitting Superseal 1 4 6 mm Filter Assy Elbow 3 8 10mm Bracket DESCRIPCIÓN DESCRIPTION Ensamblado de la Cabeza del Filtro Tornillo 8 18 x 75 PH Accesorio Supersello 3 8 10mm Accesorio Supersello 1 4 6 mm Ensamblado del Filtro Codo 3 8 10 mm Fijador Ens de tête de filtre Vis 8 18 x 75 hp Raccord Superseal 3 8 10mm Raccord Superseal 1 4 6mm Ens filtre Coude 3 ...

Reviews: