98557C (Rev. J - 8/14)

Page 4

EZWSMD*1A     EZWSM8*1A     EZWSM8*2A     LZWSMD*1A     LZWSM8*1A     LZWSM8*2A

INSTALLATION INSTRUCTIONS

1.

Install mounting frame.  See mounting frame instructions.

2.

Install remote chiller. See chiller instructions.

3.

EWF3000 WATERSENTRY PLUS FILTER INSTALLATION
(

Filtered units only. For non filtered units proceed to step 4b

)

NOTICE: Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system.

1)These filter kits must be installed in compliance with all state and local laws
and regulations governing the installation and use of this product. Maximum
inlet water temperature 100°F (38°C).
2) See filter instructions for filter assembly. Insert 3/8" elbow fitting into the
inlet side of filter head, insert 1/4" polytube or 1/4" x 90° elbow into outlet
of filter head prior to mounting the filter head assembly into the remote chiller.
3) Mount filter head to the side of the remote chiller using the filter mounting bracket and screws supplied.

CAUTION: If supply pressure will ever exceed 100 psi, install a pressure
regulator to limit the inlet pressure to the filter to 100 psi or below.
DO NOT ATTACH HOT WATER LINE TO FILTER. 

To make connections on the

filter head, loosen locknut. Push the tube end past both o-rings to a positive
stop in the filter head recess - approx. 1", locknut may have to be backed out a
little more. Screw the locknut hand tight to seal (See Fig. 5). Ends of tubing
must be cut square and free of burrs and sharp ends that could cut or nick the o-rings.

TO BOTTLE FILLER

CHILLER

INLET

PLUMBING DIAGRAM

FIG. 6

4a. Make water supply connections for Fltered units. Install a shut-off valve and union connection to building water supply

(valve and union not provided).  Turn on the water supply and flush the line thoroughly.

4b. Make water supply connections for Non Fltered units. Install a shut-off valve and union connection to building water

supply (valve and union not provided).  Turn on the water supply and flush the line thoroughly. Install the in-line strainer
between the valve and the cooler. The in-line strainer is not installed on filtered units.

5.

(

Filtered units only. For non filtered units proceed to step 7

)

Make connection between filter head and building supply line. Insert the 3/8" water line into the inlet side of the filter
head by pushing it in until it reaches a positive stop, approximately 3/4" (19mm). Install two 1/4" x 1/4" unions (provided)
on the chiller. One on the inlet tube, and the other on the outlet tube.

6.

Make connection between the filter head and the remote chiller.  Insert end of 1/4" O.D. poly tubing from the filter head
(provided) into union on chiller inlet.

7.

Mount the upper panel to  the mounting frame, aligning holes in the hinge brackets with holes in the mounting frame
(three places). Mount with adequate size screws (not provided). Close the door and verify that the lock brackets on the
side and bottom of the panel align with the slots on the mounting frame. Also verify that the panel is hanging high enough
that it covers the top of the mounting frame. If adjustments need to be made, open the door and loosen the three screws
on the hinge and adjust accordingly and then retighten the screws.

8.

Connect water line from the water station by inserting the 1/4" O.D. poly tubing into the union on the chiller outlet.

9.

Close the upper door and attach the drain fittings to drain tube. Re-attach elbow to p-trap and cut waste tube to
required length using plumbing hardware and trap as a guide.

NOTE: SCREW THE LOCKNUT

HAND TIGHT TO SEAL

FIG. 5

FILTER

CHILLER

TO BOTTLE FILLER

INLET

STRAINER

NON FILTERED

FILTERED

Summary of Contents for LZWSM8K

Page 1: ...WATER LINES IS A COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCURAWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTOAFOUNTAIN CREATINGAN ELECTROLYSIS WHICH CAUS...

Page 2: ...98557C Rev J 8 14 Page 2 EZWSMD 1A EZWSM8 1A EZWSM8 2A LZWSMD 1A LZWSM8 1A LZWSM8 2A FIG 3 LZWSM8 LZWSMD EZWSM8 EZWSMD ROUGH IN...

Page 3: ...Page 3 98557C Rev J 8 14 EZWSMD 1A EZWSM8 1A EZWSM8 2A LZWSMD 1A LZWSM8 1A LZWSM8 2A LZWSM8P LZWSMDP EZWSM8P EZWSMDP ROUGH IN FIG 4...

Page 4: ...er supply valve and union not provided Turn on the water supply and flush the line thoroughly 4b Make water supply connections for Non Fltered units Install a shut off valve and union connection to bu...

Page 5: ...Bottle Filler the LCD Bottle Counter should illuminate 15 Verify proper dispensing by placing cup hand or any opaque object in front of sensor area and verify water dispenses Note the first initial d...

Page 6: ...green LED should now be illuminated indicating that the visual filter monitor has been reset SETTING RANGE OF THE IR SENSOR 1 Depress the program button for approximately 2 seconds until the display c...

Page 7: ...play will go back to bottle counter and be in run mode 6 Test bottle filler by placing bottle or hand in front of sensor to make sure water is dispensed SETTING UNIT TYPE 1 Depress the program button...

Page 8: ...ed allow approximately 4 seconds to pass and then the display will go back to bottle counter and be in run mode 6 Test bottle filler by placing bottle or hand in front of sensor to make sure water is...

Page 9: ...fault back to bottle count and be back in run mode 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit...

Page 10: ...ea Fig 8 LISTE DES PI CES DU FILTRE Voir Fig 8 1 2 3 4 5 6 7 WATER FILTER EXPLODED VIEW FIG 8 PRINTED IN U S A IMPRESO EN LOS E E U U IMPRIM AUX U FORPARTS CONTACTYOURLOCALDISTRIBUTORORCALL1 800 834 4...

Reviews: