background image

Page 7

1000002684  (Rev. A - 07/18)

EZS8WS_2G, LZS8WS_2G, LZSDWS_2G

Service: Inspection/Replacement

         •        Inspect Bottle Filler and Cooler twice each year for proper operation and performance.

         •        Inspection of the unit will require disconnecting electrical supply, removal of panels, etc. and reassembly and return to service practices.

1.     Lower Front Panel and Upper Shroud: To access the refrigeration system and plumbing connections, remove four (4) screws from bottom of

        cooler to remove the lower front shroud. To remove the upper shroud for access to the pushbars, regulator, solenoid valve or other

        components located in the top of the unit, remove lower shroud, disconnect drain, remove four screws from tabs along lower edge of upper

        shroud, unplug two wires and water tube.

2.     Bubbler

: To remove the bubbler, first disconnect the electrical supply. The underside of the bubbler

        can be reached through the access panel on the underside of the upper shroud. Remove the

        access panel by removing the retaining screw. To remove the bubbler, loosen locknut from the

        underside of the bubbler and remove the tubing from the quick connect fitting (see above). When

        installing replacement bubbler and pedestal, tighten locknut only to hold parts snug in position. 

Do  

 

Not Overtighten. 

After servicing, replace the lower front panel and four (4) screws.

3.     Switches Behind the Push Bar: The regulator in an EZ cooler is always held fully open by the use

        of a single regulator nut.  Water is not dispensed until the pushbar is depressed to

        activate a switch which then opens a solenoid valve. When installing the regulator nut, the

        regulator spring must be depressed while turning the nut.

        To remove sidebars, from the inside compress the flared tabs and pull out careful. To reinstall side

        pushbars, the front of the pushbar is inserted first. While keeping the switch depressed, snap the

        rear of the pushbar into position.

4.     Cleaning In-Line Strainer: Unscrew the cap of the In-Line Strainer. Remove screen and rinse

 

thoroughly with water. Insert screen back into solenoid valve and screw cap on.  Make sure the    

 

o-ring is placed properly.

Replacement Parts: WaterSentry Filter Parts List

Item 

No.

1

2

3

Part No.

51300C

98926C

0000000746

Description

Filter Assy-3000 Gal.

Kit-Filter Head Fitting Includes     

John Guest Fittings

Assy-Filter & Bracket includes Filter 

Head/Mounting Bracket/John Guest 

Fittings/Screws

1

2

3

2

WATER FILTER EXPLODED VIEW

Summary of Contents for LZS8WSS2K

Page 1: ...fter installation keep these instructions in a safe location for future reference Electric supply must be identical in voltage cycle and phase to that specified on nameplate Electrical supply must have Ground Fault Circuit Interrupter GFCI protection A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules This is to allow ele...

Page 2: ...1 4 Remove the four 4 screws holding the lower front panel at the bottom of cooler Remove the front panel by pulling straight down and set aside Installation Water Line connection 1 Ensure Mains Water Supply has Water Shut off Valve with 3 8 9 5mm compression outlet 2 Connect loose end of supplied 3 8 9 5mm unplated copper tube to Water Shut off Valve Other end of tube should be connected to inlet...

Page 3: ...e and yellow wires from coolers to the purple and yellow wires on the back of the unit purple to purple yellow to yellow Lay Bottle Filler on water cooler basin and cut insulation from tube even with bottom of gasket remove this insulation from the 3 8 tube but do not discard Feed the waterline through the hole on top of water cooler NOTE To prevent scratching the basin place a towel or soft cloth...

Page 4: ...t plug end of International Cord Sets from the Cooler and Bottle Filler into electrical outlet Be sure to reinstall fuse to the circuit or switch the circuit breaker back to the ON position 12 13 14 16 15 18 17 21 20 19 Once power is applied to Bottle Filler the GREEN LED light should illuminate showing good filter status along with the LCD Bottle Counter Verify proper dispensing by placing cup ha...

Page 5: ... the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode Continued from below 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter capacity RST ...

Page 6: ...nly be cleaned with mild soap and water or Windex glass cleaner and a clean soft cloth Use of harsh chemicals or petroleum based or abrasive cleaners will void the warranty 2 Bubbler Mineral deposits on the orifice can cause water flow to spurt or not regulate Mineral deposits may be removed from the orifice with a small round file not over 1 8 3 mm diameter or small diameter wire CAUTION DO NOT f...

Page 7: ... quick connect fitting see above When installing replacement bubbler and pedestal tighten locknut only to hold parts snug in position Do Not Overtighten After servicing replace the lower front panel and four 4 screws 3 Switches Behind the Push Bar The regulator in an EZ cooler is always held fully open by the use of a single regulator nut Water is not dispensed until the pushbar is depressed to ac...

Page 8: ...6299C 1000004564 1000001812 36004C 97446C 36300C 27416C 27413C See Filter Table 36066C 36067C 28030C 35826C Description Hanger Bracket Basin Stainless Steel Wiring Front Side Push Bar Compr Service Pak 230V 50Hz Polytube Cut To Length Assy Shroud Upper Front Side Push Drier Kit Drain Replacement EZ BF Brckt Tube Ftg Clamp In Line Strainer Kit Solenoid Valve Regulator Assy Kit Flexi Bubbler O Ring ...

Reviews: