![Elkay EZOOSTL8LC Installation And Use Manual Download Page 7](http://html1.mh-extra.com/html/elkay/ezoostl8lc/ezoostl8lc_installation-and-use-manual_2392889007.webp)
Page 7
EZOOTL8*1A LZOOTL8*1A
1000005928 (Rev. B - 01/21)
B
F
‰
‰
18-3/8" (467mm)
6-3/8" (162mm)
6-3/8" (162mm)
6-3/8" (162mm)
6-3/8" (162mm)
18-3/8" (467mm)
9/32" (7mm)
2"
(51mm)
ELECTRIC EYE
LOCATION
DIA (12)
E
E
F
FILTER
A
(ALT.LOCATION)
D
(ALT.LOCATION)
28-13/16" (732mm)
21-7/8" (556mm)
13-15/16" (354mm)
3-7/8" (98mm) 7"
(178mm)
19"
(483mm)
5-3/4" (146mm)
7/8"
(22mm)
2"
(51mm)
2"
(51mm)
2"
(51mm)
7"
(178mm)
FINISHED FLOOR
D
PREFFERED LOCATION
A
PREFFERED LOCATION
19-7/16" (494mm)
22-15/16" (583mm)
24-1/2" (622mm)
34-5/16" (872mm)
38-3/8" (975mm) ORIFICE HEIGHT
32-7/8" (835mm) ORIFICE HEIGHT
36-13/16" (936mm)
RIM
HEIGHT
31-5/16" (796mm)
RIM
HEIGHT
27"
(686mm)
ADA
REQUIREMENT
12-1/2" (318mm)
17/16" (37mm)
8-1/16" (205mm)
FILTER
C
3"
(76mm)
19"
(484mm)
HANGER BRACKET
AL
TERNA
TE INST
ALLA
TON ROUGH-IN FOR BI-LEVEL
MODELS
LEGEND
/LEYENDA
/LÉGENDE
A
=
RECOMMENDED
W
ATER
SUPPL
Y
LOCA
TION
3
/8
”
O
.D
. UNPLA
TED
COPPER
TUBE
CONNECT
STUB
WITH
SHUT
OFF
(BY
OTHERS
) 3
”
(7
6mm
) MAXIMUM
OUT
FROM
W
ALL
La
UBICACION
3/8
O
RECOMENDADA
de
ABASTECIMIENT
O
DE
AGUA.
D.
El
TUBO
del
COBRE
de
UNPLA
TED
CONECT
A
TALONARIO
CON
AP
AGO
(POR
OTROS)
3
en.
(76
Mm)
el
MAXIMO
FUERA
DE
P
ARED
L’O.D
de
3/8
d’EMPLACEMENT
DE
PROVISION
D’EAU
RECOMMANDE.
LE
TUBE
DE
CUIVRE
DE
UNPLA
TED
CONNECTE
STUB
A
VEC
ETEINT
(P
AR
LES
AUTRES)
3
dans.
(76
mm)
le
MAXIMUM
HORS
DU
MUR
B
=
RECOMMENDED
LOCA
TION
FOR
W
ASTE
OUTLET
1
-1
/2
”
O
.D
.
DRAIN
STUB
2
”
OUT
FROM
W
ALL
UBICACIÓN
RECOMENDADA
P
ARA
EL
DRENAJE
DE
SALIDA
DE
AGUA
, DE
1
-1
/2
” DE
DIÁMETRO
. El
T
ALONARIO
2
FUERA
DE
P
ARED
EMPLACEMENT
RECOMMANDÉ
POUR
LE
DRAIN
DE
D
.E
. 1
-1
/2
” DE
SOR
TIE
D
’EAU
. STUB
2
HORS
DU
MUR
C
=
1
-1
/2
”
TRAP
NOT
FURNISHED
PURGADOR
DE
1
-1
/2
NO
PROPORCIONADO
SIPHON
1
-1
/2
NON
FOURNI
D
=
ELECTRICAL
SUPPL
Y
(3
) WIRE
RECESSED
BOX
CAJA
RECESIV
A
DE
ALAMBRES
(3
) DE
SUMINISTRO
ELÉCTRICO
BOÎTE
ENCASTRÉE
D
’ALIMENT
ATION
ÉLECTRIQUE
(3
) FILS
E
=
INSURE
PROPER
VENTILA
TION
BY
MAINT
AINING
6
”
(1
52
mm
) (
MIN
.)
CLEARANCE
FROM
CABINET
LOUVERS
T
O
W
ALL
.
ASEGURE
UNA
VENTILACIÓN
ADECUADA
MANTENIENDO
UN
ESP
ACIO
E
6
” (
15
2
mm
) (
MÍN
.)
DE
HOLGURA
ENTRE
LA
REJILLA
DE
VENTILACIÓN
DEL
MUEBLE
Y
LA
P
ARED
ASSUREZ
-VOUS
UNE
BONNE
VENTILA
TION
EN
GARDANT
6
” (
15
2
mm
) (
MIN
.)
ENTRE
LES
ÉVENTS
DE
L
’ENCEINTE
ET
LE
MUR
.
F
=
7/
16
”
BOL
T
HOLES
FOR
F
ASTENING
UNIT
T
O
W
ALL
AGUJEROS
DE
LAS
TUERCAS
DE
7
/1
6
PARA
SUJET
AR
LA
UNIDAD
A
LA
P
ARED
TROUS
D
’ÉCROUS
7
/1
6
POUR
FIXER
L
’APP
AREIL
AU
MUR
**
NEW
INST
ALLA
TIONS
MUST
USE
GROUND
F
AUL
T
CIRCUIT
INTERRUPTERS
(GFCI
)
**
LAS NUEV
AS INST
ALACIONES DEBEN UTILIZAR LOS INTERRUPT
ORES DE CIRCUIT
O DE TIERRA
DE LA
A
VERÍA
(GFCI)
**LES NOUVELLES INST
ALLA
TIONS DOIVENT EMPLOYER LES INTERRUPTEURS DE CIRCUIT MOULUS DE DÉF
AUT (GFCI)
FIG. 4
REDUCE HEIGHT BY
3 INCHES FOR INST
ALLA
TION OF CHILDREN’S
ADA
COOLER