background image

EWCA8*1L   EWCA8K*1L   LWCE8*1L  LWCE8K*1L

98936C (Rev. B - 10/16

PAGE 3

14

 1

/2

"

36

m

m

5/

8"

11

m

m

 

23

"

58

m

m

1/

2"

64

 m

m

5"

12

m

m

1"

25

 m

m

1/

8"

10

m

m

7/

16

"

13

m

m

3/

4"

19

 m

m

7/

16

"

13

m

m

18

"

45

m

m

22

"

55

m

m

3/

4"

19

 m

m

C

E

E

A

B

D

G

F

40

" (

10

16

m

m

)

RE

CO

M

M

EN

D

E

D

 H

EI

G

HT

FO

A

D

UL

TS

33

" (

83

8m

m

)

RE

CO

M

M

EN

D

E

D

 H

EI

G

HT

FO

CH

IL

D

RE

N

33" (838mm) RECOMMENDED  HEIGHT FOR CHILDREN

AL

TURA

 RECOMENDADA

 P

ARA

 LOS 

NIÑOS 33" (838 mm)

HAUTEUR RECOMMANDÉE POUR 

LES ENF

ANTS 33" (838mm)

FIG. 2

FINISHED FLOOR

PISO 

ACABADO

PLANCHER FINI

E = INSURE PROPER VENTILA

TION BY

 MAINT

AINING 4" (102mm) (MIN.) CLEARANCE FROM CABINET

      LOUVERS T

O W

ALL.

ASEGURE UNA

 VENTILACIÓN 

ADECUADA

 MANTENIENDO UN ESP

ACIO E 4" (102mm) (MÍN.) DE HOLGURA

 ENTRE LA

 

REJILLA

 DE VENTILACIÓN DEL

 MUEBLE 

Y LA

 P

ARED

ASSUREZ-VOUS UNE BONNE VENTILA

TION EN GARDANT

 4" (102mm) (MIN.) ENTRE LES ÉVENTS DE L

’ENCEINTE 

ET

 LE MUR.

F = POWER CORD 1-1/2' (457mm) LONG

CABLE ELÉCTRICO DE 1-1/2' (457mm) DE LARGO CORDON D’ALIMENT

ATION 1-1/2' (457mm)

G = 5/16" (8mm) SCREW HOLES IN MOUNTING PLA

TE

AGUJEROS DE 

TORNILLO 5/16" (8mm) EN LA

 PLACA

 DE MONT

AJE

TROUS DE VIS 5/16" (8mm) DANS LA

 PLAQUE DE MONT

AGE

LEGEND/LEYENDA/LÉGENDE A = RECOMMENDED W

ATER SUPPL

Y LOCA

TION 3/8 O.D. UNPLA

TED COPPER TUBE CONNECT STUB OUT 1-1/2 IN. (38mm) 

FROM W

ALL

 SHUT OFF BY

 OTHERS

 

 

SE RECOMIENDA

 UBICAR EL

 TUBO COR

TO DE CONEXIÓN 

AL

 TUBO DE COBRE SIN CHAP

AR DE 3/8" DE DIÁM. EXT

. A

 

1-1/2" (38 

mm

) FUERA

 DE LA

 LLA

VE DE P

ASO EN LA

 P

ARED COLOCADA

 POR 

TERCEROS.

        EMPLACEMENT

 RECOMMANDÉ D'ALIMENT

ATION EN EAU P

AR 

TUBE EN CUIVRE NON PLAQUÉ DE 3/8 PO. (9,5 

mm

) D.E. 

CONNECT

ANT

 UNE 

TUY

AUTERIE DE 1-1/2 PO. (38 

mm)

 DEPUIS LE ROBINET

 D'ARR

Ê

T FOURNI P

AR D'AUTRES.

B = RECOMMENDED LOCA

TION FOR W

ASTE OUTLET 1-1/4” O.D.  DRAIN

 UBICACIÓN RECOMENDADA

 P

ARA

 EL

 DRENAJE DE SALIDA

 DE 

AGUA, DE 1¼” DE DIÁMETRO.

EMPLACEMENT

 RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SOR

TIE D’EAU.

C = 1-1/4 TRAP

 NOT FURNISHED

PURGADOR DE 1¼ NO PROPORCIONADO SIPHON 1-1/4 NON FOURNI

D = ELECTRICAL

 OUTLET LOCA

TION

UBICACIÓN DE LA

 T

OMA

 DE ELECTRICIDAD

EMPLACEMENT

 DE LA

 PRISE DE COURANT

40" (1016mm) RECOMMENDED HEIGHT  FOR ADUL

TS

AL

TURA

 RECOMENDADA

 P

ARALOS 

ADUL

TOS  40" (1016 mm)

HAUTEUR RECOMMANDÉE POUR LES  ADUL

TES 40" (1016mm)

WWW.RESTROOMDIRECT.COM      704•937•2673     129 Oakpark Dr., Unit A, Mooresville, NC 28115

Summary of Contents for EWCA Series

Page 1: ...rs d eau EWCA serie compacta pared montaje de enfriadores de agua EWCA Series Compact Wall Mount Water Coolers INSTALLATION CARE USE MANUAL Manual de Instalación Cuidado y Utilización Manuel d installation entretien utilisation WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115 ...

Page 2: ...du fluide frigorigéne HFC 134A NOTE Non refrigerated units do not include all electrical and refrigeration components shown above Other components and rough in are the same as shown NOTA Las unidades no frigorificadas no incluyen todos los componentes eléctricos y de la refrigeración demostrados arriba Otros componentes y a spero en son iguales según lo demostrado NOTE Les unités non frigorifiées ...

Page 3: ...NILLO 5 16 8mm EN LA PLACA DE MONTAJE TROUS DE VIS 5 16 8mm DANS LA PLAQUE DE MONTAGE LEGEND LEYENDA LÉGENDE A RECOMMENDED WATER SUPPLY LOCATION 3 8 O D UNPLATED COPPER TUBE CONNECT STUB OUT 1 1 2 IN 38mm FROM WALL SHUT OFF BY OTHERS SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3 8 DE DIÁM EXT A 1 1 2 38 mm FUERA DE LA LLAVE DE PASO EN LA PARED COLOCADA POR TERCERO...

Page 4: ...iller shown for reference only LOCKNUT Tuerca De fijación Écrou de Blocage FIG 5 BASIN ESTANQUE BASSIN 1 Stream height is factory set at 35 PSI If supply pressure varies greatly from this remove items Cover Nut Button and adjust screw on regulator Clockwise adjustment will raise stream and counter clockwise adjustment will lower stream For best adjustment stream should hit basin approximately 6 1 ...

Page 5: ...MPLACEZ AVEC LE MÊME SURPRES SEUR QUE CELUI UTILISÉ ORIGINALEMENT NOTE Toute correspondance au sujet des refroidis seurs d eau courante ou toute commande de pièce de rechange DOIT inclure le numéro de modèle et le numéro de série du refroidisseur ainsi que le nom et le numéro de pièce à remplacer INCLUDES RELAY OVERLOAD IF UNDER WARRANTY REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY NOTE ...