System Setup
• User Setup Menu
Set Softener Para.
Set Time of Day
Set Regen. Time
Set Water Hardness
Set Time of Day
12:12
Set Regen. Time
02:00
Set Water Hardness
150 mg/L
Setup Item
Parameter Setup Scope
Factory Setting
Set Time of Day
00:00-23:59
Current Value
Set Regen. Time
00:00-23:59
02:00
Set Water Hardness
50-999 mg/L
150 mg/L
Setup
Setup Method
Display Interface
Current Time
When locking icon is on, press Up and Down at the same time for 5s, and
the locking icon disappears.
1. Press Menu to enter “Set Softener Para.”. Refer to Picture LR1. The
system default “Set Time of Day” is chosen.
2. Press Menu again. The current time setup interface is shown in picutre
LR2. Hours value 12 fl ashes. Press Up or Down to alter.
3. Press Menu again. The current time Minutes value 30 fl ashes. Press
Up or Down to alter.
4. Press Menu again. You will hear the buzzer beep. The current time is
saved. The setup is successful.
Set Softener Para.
>> Set Time of Day
Set Regen. Time
Set Water Hardess
LR1
Set Time of Day
12:30
LR2
Regeneration Activating
Time
1. Press Menu to enter “Set Softener Para.”. Refer to Picture LR1. The
system default “Set Time of Day” is chosen.
2. Press Down to select “Set Regen. Time”. Press Menu, the regeneration
activating time setup is shown in Picture LR3. The hours 02 fl ashes.
Press Up or Down to alter.
3. Press Menu again. The regeneration activating time Minutes value 00
fl ashes. Press Up or Down to alter.
4. Press Menu again. You will hear beep of buzzer. The current time is
saved. The setup is successful.
Set Regen. Time
02:00
LR3
Tap Water Hardness
Setup
1. Press Menu to enter “Set Softener Para.”. Refer to Picture LR1. The
system default “Set Time of Day” is chosen.
2. Press Down for two times, and select “Set Water Hardness”. Press Menu,
the tap water hardness setup is shown in Picture LR4. The hardness
value 150 fl ashes. Press Up or Down to alter.
3. Press Menu again. You will hear beep of buzzer. The current time is
saved. The setup is successful.
Set Water Hardness
150 mg/L
LR4
Note:
After the water hardness is set up successfully, the operation interface displays the total remaining softening capacity.
The system uses the tap water hardness to determine when the softener should regenerate. Regeneration occurs at the next
Regeneration Activating Time. If the user feels the system regenerates too often, the user can use the tap water hardness setup
function to adjust the soft water volume.
1000003996 (Rev A - 05/2017)
Page 7