M1XSP Supplementary Instructions and Release Notes

Changes effective with this new application firmware:

NOTE: Updating will ERASE ALL linked Insteon devices!

1.

Found a reported problem of the M1XSP occasionally defaulting itself (erasing all enrolled devices) upon power up.
Added a 1 second debounce timer upon power-up before reading the state of Jumper S1.

2.

New feature - It is now possible to tell the M1XSP to totally ignore X-10 type commands heard from the M1 or from the
Insteon PLC by setting Jumper S8 to “0”.  I.E. X-10 can still travel on the X-10 connector located on the M1G board while
Insteon commands travel on the M1XSP without clashing or inteferring with one another.

Version 50.0.28 released June 2, 2008

The M1XSP stores it’s operating firmware in “Flash” memory.  This state-of-the-art memory allows electronic field updates
and eliminates the old fashion method of changing IC chips or shipping boards back to the factory.   As new firmware updates
become available, they will be posted on ELK’s website found at www.elkproducts.com.  

NOTE: Firmware updating can only

be done through the M1 Control using a Direct to PC Com port connection or an optional Ethernet Network connection.
Dial-up connections cannot be used to perform firmware updates.

How to Update:

1. Physically connect the Computer and Control using either the RS-232 Serial Port 0 or the M1XEP Ethernet Interface.

2. Open ElkRP and the account belonging to the control.  Click on the Connection menu icon and establish a connection.

Use either the 

Direct using Com_

 OR 

Network

 options.

3. On the Send/Rcv menu icon there is a selection that allows the firmware to be updated.

4. Select the device to be updated.  In this case it is a Serial Expander.  Select the update firmware option.

5. Display will show: Device name, current Firmware, Hardware, and Bootware version, and a pull down window for selecting

the update firmware.  NOTE: All update (.bin) files downloaded or received should be stored in a directory on your
computer.  Refer to the Options tab under the Setup menu in RP.  It will indicate what directory is used for the update files.

6. Click on the check box for “Update”.  If “Reprogram” or “Rollback” is displayed the firmware file is the same as OR older

that what is in the control.  Reprogramming with the same firmware is a waste of time but was included for factory testing
purposes.  Rollback is not recommended except under the guidance of Elk Technical Support.

Updating/Replacing Firmware in the ELK-M1XSP

Firmware Release Notes

Version 50.1.4 released Jan 20, 2009

Changes effective with this new application firmware:

NOTE: Updating will ERASE ALL linked Insteon devices!

1.

Found and resolved an issue when using a rule to turn on a light for a timed period using the Insteon PowerLinc MODEM.
The timer associated with the light would be erased, resulting in the light never turning off.

IMPORTANT REMINDER ABOUT THE POWERLINC MODEM:

For persons using PowerHome’s “Elk Insteon Device Loader” there is a new version required

for use with this firmware and the Powerlinc Modem (PLM).  Refer to Elk’s website

under Partner Manufacturers page for a link to the PowerHome software.

Version 50.1.2 released Jan 5, 2008

Changes effective with this new application firmware:

NOTE: Updating will ERASE ALL linked Insteon devices!

1.

Added support for the new INSTEON PowerLinc Modem which replaced the now obsolete older PLC interface.

For at least the time being this version continues to provide support for the obsolete PLC interface.

Summary of Contents for M1XSP

Page 1: ...PO Box 100 Hwy 70W Hildebran NC 28637 USA 828 397 4200 http www elkproducts com Firmware and or bootware releases contain enhancements and or resolutions for issues found in previous releases For the...

Page 2: ...llation diagrams on previous pages 6 After all connections are complete turn On the M1 Master Power Switch 7 Enroll the M1XSP into the M1 Control From the Keypad access the Installer level programming...

Page 3: ...Do the same for the data B White wire At the control splice the A1 and B1 wires to the A and B wires going to the next device Terminate the last wired device and the control JP3 ONLY The data wires w...

Page 4: ...e an M1XSP has been linked with INSTEON devices any updating to the firmware in that M1XSP will cause all memory of linked addresses to be erased requiring all devices to be re linked learned again IN...

Page 5: ...mand to the M1XSP and PLM Interface and instruct it to begin a 4 minute linking period The first device must be linked during this 4 minute time period 2 Press hold the link mechanism LampLinc SET but...

Page 6: ...Lighting device 1 A01 and ENDS at 192 L16 When setting the House and Unit codes for X 10 devices we recommend NOT using any of the low range numbers Special Option Jumper S5 With the INSTEON version...

Page 7: ...0 H11 H12 H13 H14 H15 H16 ELK Light Device 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 1...

Page 8: ...dated 4 Select the device to be updated In this case it is a Serial Expander Select the update firmware option 5 Display will show Device name current Firmware Hardware and Bootware version and a pull...

Page 9: ...he way the data is parsed which should resolve this possibility Version 50 0 26 released Mar 9 2007 Changes effective with this new application firmware NOTE Updating will ERASE ALL linked Insteon dev...

Reviews: