Relay Contacts:

COM and N\C are connected
when ELK-912 is off (no trigger).
COM and N\O are connected
when ELK-912 is on.

Power Terminals:

Powers Relay Coil (12V, 30mA)
Connect to Trigger Output

ELK-912

ELK-912 APPLICATIONS AND WIRING DIAGRAMS

Example 2:  

If control has a negative output,

connect the "+" terminal of the ELK-912 to the
control's +12V terminal.  Connect the "-" termi-
nal of the ELK-912 to the negative alarm output.

Example 4:  

ELK-912 used to switch a high-

current siren or bell from separate power supply.

N\O

C

O

M

N\C

-

+

Control Panel

+12V Aux.

+ Alarm Output

Ground (-)

ELK-912

Floodlight

120V

AC

Alarm-Activated Floodlight

Example 3:  

Floodlight activates whenever con-

trol panel is in alarm

N\

O

C

O

M

N\

C

-

+

Control Panel

+12V Aux.

+ Alarm Output

Ground (-)

ELK-912

12V Power Supply

-

-

+

+

High-Current Bell or Siren Switch

Bell or

Siren

Example 1:  

If control has a positive output,

connect the "-" terminal of the ELK-912 to the
control's ground terminal.  Connect the "+"
terminal of the ELK-912 to the positive alarm
output.

N\O

C

O

M

N\C

-

+

Control Panel

+12V Aux.

+ Alarm Output

Ground (-)

These Contacts
are Connected
when Relay is
Activated

ELK-912

Hookup Example for a Positive-Output
Control Panel.

ELK-912

N\O

C

O

M

N\C

-

+

Control Panel

+12V Aux.

- Alarm Output

Ground (-)

These Contacts
are Connected
when Relay is
Activated

Hookup Example for a Negative-Output
Control Panel