background image

Elk Products, Inc.- 3266 Hwy 70 - Connelly Springs, NC 28612    http://www.elkproducts.com

  11/20/2020

Limited Warranty

THIS WIRELESS SENSOR IS WARRANTED TO BE FREE FROM 

DEFECTS AND WORKMANSHIP FOR A PERIOD OF 2 YEARS 

FROM  DATE  OF  MANUFACTURE  EXCLUDING  BATTERIES.  

BATTERIES  USED  WITH  WIRELESS  DEVICES ARE  NOT 

WARRANTED.  

MANUFACTURER HEREBY DISCLAIMS ANY AND ALL OTHER 

WARRANTIES AND REPRESENTATIONS, WHETHER EXPRESS, 

IMPLIED, STATUTORY OR OTHERWISE INCLUDING (BUT NOT 

LIMITED TO) ANY  WARRANTIES  OF  MERCHANTABILITY  OR 

FITNESS  FOR A  PARTICULAR  PURPOSE  WITH  RESPECT 

TO  THESE  PRODUCTS AND ANY  RELATED  SOFTWARE.  

MANUFACTURER FURTHER DISCLAIMS ANY OTHER IMPLIED 

WARRANTY UNDER THE UNIFORM COMPUTER INFORMATION 

TRANSACTIONS ACT  OR  SIMILAR  LAW AS  ENACTED  BY 

ANY STATE. (USA only) SOME STATES DO NOT ALLOW THE 

EXCLUSION  OF  IMPLIED  WARRANTIES,  SO  THE ABOVE 

EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY GIVES 

YOU  SPECIFIC  LEGAL  RIGHTS AND YOU  MAY ALSO  HAVE 

OTHER LEGAL RIGHTS THAT VARY FROM STATE TO STATE.  

MANUFACTURER MAKES NO REPRESENTATION, WARRANTY, 

COVENANT  OR  PROMISE  THAT  ITS ALARM  PRODUCTS 

AND/OR  RELATED  SOFTWARE  (I)  WILL  NOT  BE  HACKED, 

COMPROMISED AND/OR CIRCUMVENTED; (II) WILL PREVENT, 

OR PROVIDE ADEQUATE WARNING OR PROTECTION FROM, 

BREAK-INS, BURGLARY, ROBBERY, FIRE; OR (III) WILL WORK 

PROPERLY IN ALL ENVIRONMENTS & APPLICATIONS.

NOTE:  Elk Products is not responsible for any changes 

or  modifications  not  expressly  approved  by  the  party 

responsible for compliance.  Such modifications could 

void the user’s authority to operate the equipment. 

FCC AND IC COMPLIANCE STATEMENT:

This equipment has been tested and found to comply with the limits 

for a Class B digital device, pursuant to Part 15 of the FCC Rules. 

These limits are designed to provide reasonable protection against 

harmful interference in a residential installation. 

This equipment generates, uses and can radiate radio frequency 

energy  and,  if  not  installed  and  used  in  accordance  with 

the  instructions,  may  cause  harmful  interference  to  radio 

communications. However, there is no guarantee that interference 

will not occur in a particular installation. 

If this equipment does cause harmful interference to radio or 

television  reception,  which  can  be  determined  by  turning  the 

equipment off and on, the user is encouraged to try to correct the 

interference by one or more of the following measures: 

•  Reorient or relocate the receiving antenna. 

•  Increase the separation between the equipment and receiver. 

•  Connect the equipment into an outlet on a circuit different from

  that to which the receiver is connected. 

•  Consult the dealer or an experienced radio/TV technician for help.

 

This device complies with Industry Canada license-exempt RSS 

standard(s). Operation is subject to the following two conditions: 

(1) this device may not cause interference, and (2) this device must 

accept  any  interference,  including  interference  that  may  cause 

undesired operation of the device.

Cet  appareil  est  conforme  avec  Industrie  Canada  exempts  de 

licence  standard  RSS  (s).  Son  fonctionnement  est  soumis  aux 

deux conditions suivantes: (1) cet appareil ne doit pas provoquer 

d’interférences et (2) cet appareil doit accepter toute interférence, 

y compris celles pouvant causer un mauvais fonctionnement de 

l’appareil.
In accordance with FCC requirements of human exposure to radio 

frequency fields, the radiating element shall be installed such that 

a minimum separation distance of 20 cm is maintained from the 

general population.

FCC ID: 2ABBZ-RF-ARPIR-319     
IC: 11817A-RFARPIR319

This  device  complies  with  Part  15  of  the  FCC  Rules.  Operation 

is  subject  to  the  following  two  conditions:  (1) This  device  may 

not  cause  harmful  interference,  and  (2)  this  device  must  accept 

any interference received, including interference that may cause 

undesired  operation.  Changes  or  modifications  not  expressly 

approved by the party responsible for compliance could void the 

user’s authority to operate the equipment.

This Class B digital apparatus complies with Canadian ICES-3B.

Cet appareil numérique de la classe B est conforme à la norme 

NMB-003 du Canada.

Recommend Installation Practices

To achieve reliable operation and best false alarm immunity 

please follow these guidelines:

•   Mount sensor on a solid flat wall surface in in a corner.
•  Surface must be solid with no vibration or movement.    
•   Height should be 7.5ft above the finished floow.
•   Sensitivity should be set to Standard
•  Position sensor where intruder would most likely walk across 

coverage pattern.

•   Pets, if present, must not be allowed to climb on objects like 

furniture, boxes, etc. that are within the field of view.

•   Do not mount near ceiling fans or heating ducts
•  Do not mount on metal surfaces as this reduces range. 

•  Avoid sensor looking directly at window or direct sunlight
•  Install sensor within 100 ft. of the receiver or panel
•  Room temperature should be between 60 and 120 F.

Walk Test and Operation 

[ 3 minute lockout ]

To conserve battery life sensor has an automatic 3-minute sleep 

mode lockout between transmissions.  
To perform Walk Testing, open sensor cover and enable the 

LED (Jumper J1 to “LED” position).  Replace cover and move 

across the monitored area (within the sensor’s optical fields-of-

view).  LED should turn ON after 2 to 4 normal steps.  Stop and 

wait 12 seconds before continuing.  When there is no motion in 

the monitored area, the LED should remain OFF.

It is recommended to not leave Jumper J1 in LED position since 

e

xcessive use of the walk test mode reduces battery life. 

Use only for initial setup and maintenance.

Battery Life and Replacement

Battery life depends on how often sensor transmits signals as 

well as temperature of the environmental.  Sensor transmits 

a low battery indication to panel when it detects the battery 

voltage is low.  

Replace the battery as soon as possible once 

the low battery is signaled using a Panasonic CR123 3V.

•  Depress cover latch on top edge and lower cover.

•  Remove  battery  from  holder  and  install  new  battery.  

Observe (+) polarity marked on the battery and circuit board.

CAUTION:  Battery may explode if mistreated.  Do not 

recharge, disassemble, incinerate or expose to heat above 

212° F (100° C).  Keep away from children.

Battery  Disposal:  This sensor uses a lithium battery 

which is not rechargeable or reuseable.  Dispose of used 

lithium batteries according to your local hazardous waste 

disposal laws.  

Reviews: