2018 Indiana Design and Installation Manual
12
www.eljen.com
2.1 Subsurface Trench and Single Lateral Bed Design Example
FIGURE 5: PLAN VIEW – 450 GPD – B43 –SINGLE LATERAL BED SYSTEM
NATIVE SOIL
DISTRIBUTION BOX
(MIN 5 FT FROM FIELD)
SPECIFIED SAND
4'
MIN 10'
3'
85'
84'
FIGURE 6: SECTION VIEW – B43 – SINGLE LATERAL BED SYSTEM – ≤ 0.5% SLOPE
48"
36"
GEOTEXTILE
FABRIC
FINAL GRADE
SPECIFIED SAND
7"
6"
MIN 12" OF
COVER SOIL
MATERIAL
48"
NATIVE SOIL
6' MIN
SPECIFIED SAND
48"
NATIVE SOIL
6' MIN
SPECIFIED SAND
Loading Rate 0.3 gpd/ft
2
, Design Flow 150 gpd x 3 Bedrooms = 450 gallons per day.
(21 Modules per Row)
FIGURE 7: SECTION VIEW – B43 – SINGLE LATERAL BED SYSTEM – 0.5 – 15% SLOPE
FINAL GRADE
7"
6"
MIN 12" OF
SOIL COVER
MATERIAL
NATIVE SOIL
6' MIN
GEOTEXTILE
FABRIC
SPECIFIED SAND
SPECIFIED SAND
48"
36"
48"
NATIVE SOIL
6' MIN
SPECIFIED SAND
48"
Loading Rate 0.3 gpd/ft
2
, Design Flow 150 gpd x 3 Bedrooms = 450 gallons per day.
(21 Modules per Row)