USING THE COPY CARD
The Copy Card is connected to the serial port (TTL) and allows rapid programming of the instrument parameters.
Access
Installer
parameters by entering ‘PA2’, scroll through the folders using
and
until folder
FPr
appears. Select it using
, scroll
through the parameters using
and
, then select the function using
(eg.
UL
).
•
Upload
(
UL
): Select UL and press
. This function uploads the programming parameters from the instrument to the card. If the
procedure is a success, ‘
y
’, will appear on the display, otherwise ‘
n
’ will appear.
•
Format
(
Fr
):
This command is used to format the copy card (recommended when using the card for the first time).
Important
: the
Fr
parameter deletes all data present. This operation cannot be cancelled.
•
Download
:
Connect the Copy Card when the instrument is switched off. At power-on, data is downloaded from the copy card to the
instrument automatically. At the end of the lamp test, the display will show ‘
dLy
’ if the operation was successful and ‘
dLn
’ if not.
NOTE:
After downloading, the instrument works with the settings of the new map just downloaded.
H13 PARAMETER CONFIGURATION
H13
D.I.
STATE
FROM KEY OR FROM MENU
FUNCTION
STATE
COMMENTS
ENABLED
DISABLED
NO
open
YES
YES
ON
enabled / disabled with each mode
NO
closed
YES
YES
OFF
enabled / disabled with each mode
NC
open
YES
YES
OFF
enabled / disabled with each mode
NC
closed
YES
YES
ON
enabled / disabled with each mode
NOP
open
YES
YES
ON
enabled only from D.I. / disabled with each mode
NOP
closed
NO
N/A
OFF
Enabled only when D.I. is reopened
NCP
open
YES
YES
OFF
enabled with each mode / disabled only from D.I.
NCP
closed
N/A
NO
ON
enabled with each mode / disabled only from D.I.