Elitex TAC-09CHSA series Service Manual Download Page 3

Note: Each mode and relevant function will be further specified in following pages. 

SLEEP

FAN

TIMER

SWING

ON/OFF

MODE

MID

SWING

AUTO

DRY
FAN
HEAT

COOL

FEEL

SLEEP TIMER ON

HIGH

LOW

TMIER OFF

The remote controller transmits signals  to the system.

Remote controller

1

2

4

3

5

6

7

8

8

4

MODE  button

FAN SPEED control button

UP button (TOO COOL button)

DOWN button (TOO WARM button) 

ON/OFF button

SLEEP  button

VANE control button

 TIMER button

Used to select the type of operation mode:  Feel, 
Cooling, Dry, Fan and Heating(Only for Heat Pump).
 

Used to select the indoor fan motor speed:
 Auto, High, Mid and Low. 

Used to increase the set room temperature

 and time.

Used to decrease the set room temperature
and time. 

Used to set or cancel sleep mode operation. 

Used to start and stop operation 
when pressed.  

Used to adjust airflow direction.

Used to select TIMER operation.

Remote controller

6

2

5

3

7

1

1

1

 Air Conditioner Service Manual

Operation Details

Remote Control

The remote  controller is  not  preset  as Cooling  Only

  

Air Conditioner  or Heat  Pump by  manufacturer.

Each time after the remote controller replace batteries or is energized, the 

 

arrowhead will flash on the front of 

Heat

or 

Cool

on LCD of the remote controller.

User can preset the remote controller type depending on the air conditioner type you have purchased as 
follows:
Press any button when the arrowhead flashes on the front o

Cool

, Cooling Only is 

 

set.

Press any button when the arrowhead flashes on the front of 

 Heat

, Heat Pump is set.

If you do

n

t press

 

 any button within 10 seconds, the remote controller is preset as Heat Pump automatically.

Note :

If the air conditioner you purchased is a Cooling Only one, but you preset 

 

the remote controller as Heat Pump, it 

doesn

t  matter. But if the air conditioner you purchased is a

 

 Heat Pump one, and you preset the remote 

controller  as Cooling Only, then you CAN NOT preset the Heating operation with the remote controller.

2

Summary of Contents for TAC-09CHSA series

Page 1: ...MANUAL No TE1307 Models TAC 09CHSA TAC 12CHSA TAC 18CHSA TAC 24CHSA 1 IMPORTANT NOTICE 2 OPERATION DETAILS 3 ELECTRICAL SCHEMATIC DIAGRAM 4 EXPLOSION VIEW 5 PARTS LIST WALL MOUNTED SPLIT TYPEAIR COND...

Page 2: ...for the interpretation of this information nor can it assume any liability in connection with its use The information specifications and parameter are subject to change due to technical modification...

Page 3: ...controller 6 2 5 3 7 1 1 1 Air Conditioner Service Manual Operation Details Remote Control The remote controller is not preset as Cooling Only Air Conditioner or Heat Pump by manufacturer Each time af...

Page 4: ...tioner Service Manual REMOTE CONTROLLER The four types of remote controller is as follow GYKQ 05 GYKQ 10e optional GYKQ 11e optional GYKQ 12e optional Note The function of remote controller above is t...

Page 5: ...ressor Outdoor fan OFF when the indoor pipe temperature is Outdoor fan ON when the indoor pipe temperature is 118 4 Compressor OFF when the indoor pipe temperature is Compressor ON when the indoor pip...

Page 6: ...selected without setting temperature the system will set the temperature at automatically with the AUTO FAN speed 2 When selecting the HEATING mode operation the system will operate according to the...

Page 7: ...the IPT is less than for 2 minutes When the defrosting operation time on this condition exceeds 8 minutes it will terminate C After the compressor operates continuously for 20 minutes and the IPT is l...

Page 8: ...he set temperature will be raised by 1 1 hour later and by 2 hour later When selecting HEATING operation with SLEEP mode the set temperature will be dropped by 1 1 hour later and 2 hour later After th...

Page 9: ...d position and then set to the desired angle The positioning is decided as follows When the ON OFF button is pressed When the vane control is change from AUTO to MANUAL When the SWING is finished When...

Page 10: ...ed or a button on the remote controller is pressed and normal operation will start NOTE Do not press the EMERGEMCY Operation switch during normal operation 14 AUTO RESTART Function Option 1 When the i...

Page 11: ...of remoter controller except the signal of shut off When the system checks the voltage is 220V and the delay control is finished it operates at normal again When the indoor fan motor is failure the co...

Page 12: ...TCL Air Conditioner Service Manual Wiring diagram Model TAC 09CHSA Indoor unit Outdoor unit 11...

Page 13: ...Air Conditioner Service Manual Wiring diagram Model TAC 12CHSA TAC 18CHSA Indoor unit Outdoor unit 12...

Page 14: ...Air Conditioner Service Manual Wiring diagram Model TAC 24CHSA Indoor unit Outdoor unit 13...

Page 15: ...Air Conditioner Service Manual Explosion view Model TAC 09CHSA TAC 12CHSA Indoor unit 15 6 11 12 8 10 9 7 5 4 3 2 18 17 16 22 21 19 20 24 23 25 26 27 1 14 13 14...

Page 16: ...Air Conditioner Service Manual Explosion view Model TAC 18CHSA Indoor unit 24 14 13 25 22 20 19 21 23 17 16 15 18 2 3 1 5 6 4 7 9 10 12 11 8 15...

Page 17: ...Air Conditioner Service Manual Explosion view Model TAC 24CHSA Indoor unit 13 14 26 25 27 22 23 19 18 17 16 21 20 24 2 1 3 5 7 6 4 15 9 10 12 11 8 16...

Page 18: ...CB 1 11 Display PCB Box 1 12 Air Filter 2 13 Front Panel 1 Option 14 Display PCB Cover 1 15 Power Supply Cord 1 16 Vane 1 17 Drainage Hose 1 18 Cable Clamp 1 19 Main PCB 1 20 Electrical Box 1 21 Vane...

Page 19: ...Display PCB Box 1 12 Left Air Filter 1 Right Air Filter 1 13 Front Panel 1 14 Display PCB cover 1 option 15 Vane 1 16 Drainage Hose 1 17 Vane Motor 1 18 Sensor Holder 1 19 Main PCB 1 20 Indoor Motor C...

Page 20: ...Box 1 12 Left Air Filter 1 Right Air Filter 1 13 Front Panel 1 14 Display PCB Cover 1 15 Electrical Box Cover 1 16 Vane A 1 17 Vane B 1 18 Drainage Hose 1 19 Cable Clamp 1 20 Vane Motor 2 21 Sensor Ho...

Page 21: ...Air Conditioner Service Manual Explosion view Model TAC 09CHSA TAC 12CHSA Outdoor unit 27 1 26 2 3 4 25 23 24 22 21 19 20 16 17 15 14 18 5 6 7 8 10 9 13 12 11 20...

Page 22: ...Air Conditioner Service Manual Explosion view Model TAC 18CHSA Outdoor unit 27 1 26 2 3 4 25 23 24 22 21 19 20 16 17 15 14 18 5 6 7 8 10 9 13 12 11 21...

Page 23: ...Air Conditioner Service Manual Explosion view Model TAC 24CHSA Outdoor unit 27 1 26 2 3 4 25 23 24 22 21 19 20 16 17 15 14 18 5 6 7 8 10 9 13 12 11 22...

Page 24: ...1 4 way Valve 1 12 4 way Valve Assembly 1 Optional 13 Outdoor Base 1 14 Right Plate 1 15 Two way Valve 1 16 Valve Supporter 1 17 Three way Valve 1 18 Electrical Box Cover 1 19 Outdoor cable Clamp 1 20...

Page 25: ...d It Accessories 1 12 Discharge Pipe 1 Optional 13 Suction Pipe 1 Optional 14 Outdoor Base 1 15 Two way Valve 1 16 Valve Supporter 1 17 Three way Valve 1 18 Right Plate 1 19 Electrical Box Cover 1 20...

Page 26: ...Valve 1 12 4 way Valve Assembly 1 Optional 13 Outdoor base 1 14 Right Plate 1 15 Two way Valve 1 16 Valve Supporter 1 17 Three way Valve 1 18 Electrical Box Cover 1 19 Outdoor Cable Clamp 1 20 Outdoo...