Elitex TAC-09CHSA series Service Manual Download Page 18

  Air Conditioner Service Manual 

 

 

 

Part list 
Model:

 

TAC-09CHSA/*** / TAC-12CHSA/***

 

Indoor unit 
 

No. Part 

Name 

Q’ty 

Remark 

1 Installation 

Plate 

 

 

2 Base 

 

 

3 Cross 

Fan 

 

 

4 Bearing 

Mount 

 

 

5 Evaporator 

 

 

Water Drainage Assembly 

 

 

7 Vertical 

Vane 

Assembly 

10 

 

 

8 Face 

Frame 

 

 

9 Screw 

Cover 

 

 

10 Display 

PCB 

 

 

11 Display 

PCB 

Box 

 

 

12 Air 

Filter 

 

 

13 Front 

Panel 

1 Option 

14 Display 

PCB 

Cover 

 

 

15 

Power Supply Cord 

 

 

16 Vane 

 

 

17 Drainage 

Hose 

 

 

18 Cable 

Clamp 

 

 

19 Main 

PCB 

 

 

20 Electrical 

Box 

 

 

21 Vane 

Motor 

 

 

22 Sensor 

Holder 

 

 

23 Indoor 

Motor 

 

 

24 

Indoor Motor Clamp 

 

 

25 Transformer 

 

 

26 

Indoor Sensor Assembly 

 

 

27 

In And Out Pipe Fixer 

 

 

28 

Remote Controller 

Not shown in 

Explosion view 

29 

Remote Controller Supporter 

30 Indoor 

Carton 

31 Left 

Foaming 

32 Right 

Foaming 

 
 
 
 
 

17

Summary of Contents for TAC-09CHSA series

Page 1: ...MANUAL No TE1307 Models TAC 09CHSA TAC 12CHSA TAC 18CHSA TAC 24CHSA 1 IMPORTANT NOTICE 2 OPERATION DETAILS 3 ELECTRICAL SCHEMATIC DIAGRAM 4 EXPLOSION VIEW 5 PARTS LIST WALL MOUNTED SPLIT TYPEAIR COND...

Page 2: ...for the interpretation of this information nor can it assume any liability in connection with its use The information specifications and parameter are subject to change due to technical modification...

Page 3: ...controller 6 2 5 3 7 1 1 1 Air Conditioner Service Manual Operation Details Remote Control The remote controller is not preset as Cooling Only Air Conditioner or Heat Pump by manufacturer Each time af...

Page 4: ...tioner Service Manual REMOTE CONTROLLER The four types of remote controller is as follow GYKQ 05 GYKQ 10e optional GYKQ 11e optional GYKQ 12e optional Note The function of remote controller above is t...

Page 5: ...ressor Outdoor fan OFF when the indoor pipe temperature is Outdoor fan ON when the indoor pipe temperature is 118 4 Compressor OFF when the indoor pipe temperature is Compressor ON when the indoor pip...

Page 6: ...selected without setting temperature the system will set the temperature at automatically with the AUTO FAN speed 2 When selecting the HEATING mode operation the system will operate according to the...

Page 7: ...the IPT is less than for 2 minutes When the defrosting operation time on this condition exceeds 8 minutes it will terminate C After the compressor operates continuously for 20 minutes and the IPT is l...

Page 8: ...he set temperature will be raised by 1 1 hour later and by 2 hour later When selecting HEATING operation with SLEEP mode the set temperature will be dropped by 1 1 hour later and 2 hour later After th...

Page 9: ...d position and then set to the desired angle The positioning is decided as follows When the ON OFF button is pressed When the vane control is change from AUTO to MANUAL When the SWING is finished When...

Page 10: ...ed or a button on the remote controller is pressed and normal operation will start NOTE Do not press the EMERGEMCY Operation switch during normal operation 14 AUTO RESTART Function Option 1 When the i...

Page 11: ...of remoter controller except the signal of shut off When the system checks the voltage is 220V and the delay control is finished it operates at normal again When the indoor fan motor is failure the co...

Page 12: ...TCL Air Conditioner Service Manual Wiring diagram Model TAC 09CHSA Indoor unit Outdoor unit 11...

Page 13: ...Air Conditioner Service Manual Wiring diagram Model TAC 12CHSA TAC 18CHSA Indoor unit Outdoor unit 12...

Page 14: ...Air Conditioner Service Manual Wiring diagram Model TAC 24CHSA Indoor unit Outdoor unit 13...

Page 15: ...Air Conditioner Service Manual Explosion view Model TAC 09CHSA TAC 12CHSA Indoor unit 15 6 11 12 8 10 9 7 5 4 3 2 18 17 16 22 21 19 20 24 23 25 26 27 1 14 13 14...

Page 16: ...Air Conditioner Service Manual Explosion view Model TAC 18CHSA Indoor unit 24 14 13 25 22 20 19 21 23 17 16 15 18 2 3 1 5 6 4 7 9 10 12 11 8 15...

Page 17: ...Air Conditioner Service Manual Explosion view Model TAC 24CHSA Indoor unit 13 14 26 25 27 22 23 19 18 17 16 21 20 24 2 1 3 5 7 6 4 15 9 10 12 11 8 16...

Page 18: ...CB 1 11 Display PCB Box 1 12 Air Filter 2 13 Front Panel 1 Option 14 Display PCB Cover 1 15 Power Supply Cord 1 16 Vane 1 17 Drainage Hose 1 18 Cable Clamp 1 19 Main PCB 1 20 Electrical Box 1 21 Vane...

Page 19: ...Display PCB Box 1 12 Left Air Filter 1 Right Air Filter 1 13 Front Panel 1 14 Display PCB cover 1 option 15 Vane 1 16 Drainage Hose 1 17 Vane Motor 1 18 Sensor Holder 1 19 Main PCB 1 20 Indoor Motor C...

Page 20: ...Box 1 12 Left Air Filter 1 Right Air Filter 1 13 Front Panel 1 14 Display PCB Cover 1 15 Electrical Box Cover 1 16 Vane A 1 17 Vane B 1 18 Drainage Hose 1 19 Cable Clamp 1 20 Vane Motor 2 21 Sensor Ho...

Page 21: ...Air Conditioner Service Manual Explosion view Model TAC 09CHSA TAC 12CHSA Outdoor unit 27 1 26 2 3 4 25 23 24 22 21 19 20 16 17 15 14 18 5 6 7 8 10 9 13 12 11 20...

Page 22: ...Air Conditioner Service Manual Explosion view Model TAC 18CHSA Outdoor unit 27 1 26 2 3 4 25 23 24 22 21 19 20 16 17 15 14 18 5 6 7 8 10 9 13 12 11 21...

Page 23: ...Air Conditioner Service Manual Explosion view Model TAC 24CHSA Outdoor unit 27 1 26 2 3 4 25 23 24 22 21 19 20 16 17 15 14 18 5 6 7 8 10 9 13 12 11 22...

Page 24: ...1 4 way Valve 1 12 4 way Valve Assembly 1 Optional 13 Outdoor Base 1 14 Right Plate 1 15 Two way Valve 1 16 Valve Supporter 1 17 Three way Valve 1 18 Electrical Box Cover 1 19 Outdoor cable Clamp 1 20...

Page 25: ...d It Accessories 1 12 Discharge Pipe 1 Optional 13 Suction Pipe 1 Optional 14 Outdoor Base 1 15 Two way Valve 1 16 Valve Supporter 1 17 Three way Valve 1 18 Right Plate 1 19 Electrical Box Cover 1 20...

Page 26: ...Valve 1 12 4 way Valve Assembly 1 Optional 13 Outdoor base 1 14 Right Plate 1 15 Two way Valve 1 16 Valve Supporter 1 17 Three way Valve 1 18 Electrical Box Cover 1 19 Outdoor Cable Clamp 1 20 Outdoo...

Reviews: