W I R I N G A D D I T I O N A L I N P U T S
16 15 14 13
11 10 9 8
6
3 2
1
16 15 14 13 12 11 10 9
8 7 6
5 4 3
2
1
J3 Plug
Connector
J3 Plug
J3 Plug
Connector
Important:
Wiring at
7
and
12
will be recognized as an
Open Only
command, and
Will Not
close the gate. To
Close
the
gate with this wiring configuration, the control board
timer must be turned
ON
. If the timer is not turned on,
the gate will remain open. To provide close command
use 4 and 5.
Wiring at
4
and
5
will be recognized as a
Three Push Button
command. The
First
command will
open
the gate. The
Second
command will
stop
the gate. The
Third
command will
close
the
gate.
black
1 (24V) / Ground
2 (Relay)
3 (Radio Power) / +24V
white
red
Elite Entry Phone
Pin 7 and 12 for
Open Only
command
Input for
3 push button
control
Exit Loop
Detector
1
2
3
Mount receiver inside the control board
box as shown using velcro. Note that the
receiver is mounted upside down so the
antenna can fit through the hole at the
bottom of the control board box.
Control Board
Push Button
Card Reader
Digital Lock
Key Switch
Card Reader
Digital Lock
4
7
8
0
HELP
9
1
2
3
5
6
12
12
7
5 4
18