6. Installation and use of the TIG process
1.
Turn on the machine.
2.
Select the current according to the filler diameter to be melted.
3.
Cable connection: The TIG torch must be connected to the connector with negative
polarity and the work clamp with positive polarity.
GAS installation
IN TIG the gas must be
directly connected to the
torch and the beginning of
the arc is given by Lift Arc.
The gas used must be
Argon or Helium, the
cylinder must have a
pressure regulator and a
gas flow of 16 to 20 l / m or
32 to 40 CFH is
recommended