6
Disabled no trouble beep will be generated.
Option 4 - Device Power Up Disarmed
5
Enabled the system will power up disarmed regardless
of the system status at the time power was lost.
6
Disabled the system will power up in an exit delay
condition if the power to the EliteSuite device was
turned off during an exit delay cycle or if the system
was in alarm or armed.
Option 5 – Reader Slave Network
5
Enabled the Slave Communications Port will be used
to communicate with Card Reader Interfaces via a
Standalone Module.
6
Disabled the Slave Communications Port will not be
used.
Option 6 – PGM Output Follows Alarm Status
5
Enabled the PGM Output will be enabled with the
alarm siren time activation or fire alarm activation.
6
Disabled the PGM Output will not change state
regardless of the alarm status.
Option 7 – PGM Output Follows Area Status
5
Enabled the PGM Output will be enabled when the
EliteSuite system is armed, and disabled when the
system is disarmed.
6
Disabled the PGM Output will not change state
regardless of the area status.
Option 8 – PGM Output Inversion
5
Enabled the PGM Output will follow the operation
programmed by options 6 and 7, but the output will
be opposite to the behaviour described in those
functions.
6
Disabled the PGM Output will follow the programmed
output behaviour of options 6 and 7.
18
ELT-KLED EliteSuite Installation Manual