28

4'

4'

4'

4'

 Typical

OUT

IN

4'

Exit

Loop

4'

The exit loop automatically allows the gate to open when vehicle is exiting.

10 feet to 13 feet
14 feet to 26 feet
27 feet to 45 feet

46 feet to 100 feet

101 feet and up

Loop Perimeter

Important

Number of Turns

5
4
3
2
1

1/8" to 1/4" 
Saw Slot

Road Surface

Sealant

Loop Wire

(3 Wires Shown,

amount varies. 

Refer to table)

Min 1"

Home Run

The wire is continuously wound in 
the loop saw slot for the required 
number of turns. One turn shown. 

(Refer to table above)

The wire must be twisted together 6 twists per foot from 
the end of the loop to the loop detector connection.

Remove sharp inside corners 
by making corner cuts

Home Run

1/8" to 1/4" 
Saw Slot

Recommended Loop Wire

XLPE 12-18 gauge
USE 12-18 gauge

Use heavier wire gauge for a more 
durable loop area

E X I T   L O O P   S Y S T E M

Summary of Contents for SL-3000-UL Series

Page 1: ...V 1102 Click on the desired topic in the Bookmarks column or Table of Contents to select page...

Page 2: ...justing Gate Traveling Distance 17 Adjustable Timer 17 Two Way Adjustable Reversing Sensor 18 Master and Slave with Timer On 19 Master and Slave with Timer Off 20 Solenoid Maglock J3 Connection 21 Ins...

Page 3: ...n a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment Swinging gates shall not open into public access ar...

Page 4: ...bottom edge of a vehicular vertical lift gate 3 One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate 4 A hard wired contact sensor shall be located and i...

Page 5: ...UST reverse on contact with a rigid object or stop when an object activates the non contact sensors After adjusting the force or the limit of travel retest the gate operator Failure to adjust and rete...

Page 6: ...rage or parking area associated therewith Commercial General access vehicular gate operator Class II A vehicular gate opera tor or system intended for use in a commer cial location or building such as...

Page 7: ...permit a 2 1 4 inch sphere to pass through any location including the area of the adjacent fence covered when the gate is in the open position Install the gate operator according to the manufacturer s...

Page 8: ...height including the area of the adjacent fence covered when the gate is in the open position Always be certain that the gate area is clear of pedestrians before operating the gate R O L E O F E N D...

Page 9: ...etween Gate and Wall or Other Object Gate in Fully Opened Position 1 4 Clearance from Top of Gate 5 8 G AT E P O S T W A R N I N G For safety reasons a physical stop must be installed on the gate prio...

Page 10: ...cedure The UL required Warning Signs must be installed in plain view and on both sides of each gate installed Each sign is made with fas tening holes in each corner and should be permanently secured i...

Page 11: ...ross the path of a moving gate Property owners must never allow anyone to hang or ride on the gate Property owners must never mount any gate operating device near the gate s path The SL 3000 Series is...

Page 12: ...te Weight 2000 lbs Maximum Pull 180 lbs Recommended Gate Setup Configuration Warning Signs Attached on Both Sides of Gate Non Pinch Rollers Sensor Edges Sensor Edges Non Pinch Rollers Warning Sign Cle...

Page 13: ...It is highly recommended installing over travel stops at both ends of the gate rail in any type of installation to prevent derailing R E A R I N S TA L L AT I O N S REASON CHAIN IS NOT VISIBLE F R O N...

Page 14: ...the chain access slot on the one side of the cover to the exact specifications Important For safe operation of the gate opener do not cut the slots any wider or longer than shown DO NOT modify the hou...

Page 15: ...on Physical Stops on Both Ends of Rail Cover over Wheel Physical Stops on Both Ends of Rail 10 8 12 12 Red Head Fastener 1 2 x 3 1 2 Conduit Area Without Battery Back Up Follow gate manufacturers spec...

Page 16: ...OOP CENTER LOOP GATE LOCKED 60 POWER OVERLOAD OFF W4 OPEN LEFT DC BACKUP ALARM SENSOR OPEN RIGHT 3 SENSORS RESET MOTOR 1 3 1 3 COMMAND PROCESSED ON G B MS LINK A MADE IN USA RADIO MER 60 OFF 1 3 ON OP...

Page 17: ...Installation 12 gauge wire Elite Access Systems is not responsible for improper installation or failure to comply with all necessary local building codes 8 ft The earth ground rod must be located wit...

Page 18: ...MER NSOR 60 OFF OPEN LEFT OPEN RIGHT 3 1 3 ON Timer OFF Set Timer 1 to 60 seconds Timer can be set from 1 to 60 seconds Timer ON or for push open push close type operation Timer OFF Note When using ma...

Page 19: ...N If the power supply to the gate operator is less than 99 volts adjust the alarm by turning the alarm adjustment counter clockwise enough to actuate the alarm when obstructed but not sensitive enough...

Page 20: ...ED 60 POWER OVERLOAD OFF W4 OPEN LEFT DC BACKUP ALARM SENSOR OPEN RIGHT 3 SENSORS RESET MOTOR 1 3 1 3 COMMAND PROCESSED ON G B MS LINK A MADE IN USA TIMER TIMER NSOR 60 OFF OPEN LEFT OPEN RIGHT 3 1 3...

Page 21: ...PEN LEFT OPEN RIGHT 3 1 3 ON TIMER TIMER NSOR 60 OFF OFF OPEN LEFT OPEN RIGHT 3 1 3 ON Master Omni Board Slave Omni Board 1 Connect G from the master surge suppressor to G of the slave surge suppresso...

Page 22: ...A Connection of a Solenoid or Magnetic Lock can be made using the J3 plug and three wires supplied with the unit J3 2 8 10 9 7 1 3 Insert 2 supplied wires into J3 plug 3 and 7 Motor Harness 3 Normally...

Page 23: ...Common Normally Closed Normally Open Maglock 1 2 3 4 5 6 7 8 9 Master Slave RS485 Burglar Alarm Output Burglar Alarm Input Ground B A 10 11 12 13 14 15 16 Solenoid Gnd Gnd Gnd Gnd Gnd B A N O N O N O...

Page 24: ...mally Closed 9 Normally Open CENTER SAFETY EXIT CENTER SAFETY EXIT FIRE DEPT 1 3 STRIKE OPEN RADIO RECEIVER TIMER SYSTEM ON EXIT LOOP ALARM SENSOR REVERSE SENSOR OPEN STOP CLOSE SAFETY LOOP CENTER LOO...

Page 25: ...e option is needed H O U S E A L A R M P R O X I M I T Y S W I T C H CENTER SAFETY EXIT CENTER SAFETY EXIT FIRE DEPT 1 3 STRIKE OPEN RADIO RECEIVER TIMER SYSTEM ON EXIT LOOP ALARM SENSOR REVERSE SENSO...

Page 26: ...ush button is dry contact and there are no jumper wires between them IMPORTANT The Stop button must be Normally Closed 2 4 and 6 are common on Omni Option board for a 4 wire installation N O N O Com C...

Page 27: ...dio Receiver External Exit Loop Detector Master Slave Operator External Safety Loop Detector Photo Cell Phone Entry Push Button Card Reader Fire or Any Key Switch 4 7 8 0 HELP 9 1 2 3 5 6 Red 24 Volt...

Page 28: ...safety loops or the electric fields will interfere with each other Home Run The wire is continuously wound in the loop saw slot for the required number of turns One turn shown Refer to table above The...

Page 29: ...Wire 3 Wires Shown amount varies Refer to table Min 1 Home Run The wire is continuously wound in the loop saw slot for the required number of turns One turn shown Refer to table above The wire must be...

Page 30: ...ng loaded pin Turn the power OFF to the gate operator and unlock the fire box Pull firmly on the T Handle to release the chain Option 2 Model DC 1000U SL OPTION A In case of power failure the gate ope...

Page 31: ...onal stop button Refer to the next page Refer to troubleshooting table W4 W4 OFF ON OFF ON Disconnect the wire harnesses from OmniControl board Unscrew 3 nuts to remove board The gate is too heavy 1 T...

Page 32: ...OSE 1 2 3 4 5 6 Stop Button 3 N C 4 Com W4 31 S T O P B U T T O N A L A R M S H U T O F F This is an important command required to stop the audio alarm in case it has been triggered Otherwise the alar...

Page 33: ...ent protection for your installation to prevent injury Recommended Edge Sensor Locations Edge Sensor Recommended Location Edge Sensor Recommended Location SL Top View of Gate Operation Recommended Ins...

Page 34: ...nected to Sensor Input Gate in Open Position Fence Danger Edge Sensor Connected to Safety Input Non Pinch Rollers 4 Wires go to Gate Operator Omni Control Board and Electronic Box Terminals Sensing Ed...

Page 35: ...Light Remains ON Always W4 OFF ON Reset Motor LED Light flashes once then System On LED slowly flashes Remote Control has malfunctioned in the ON Position Radio Receiver in the Gate Operator has malfu...

Page 36: ...is is a normal response of the gate operator It does not represent necessarily that there is a problem TIMER LED BLINKING And COMMAND PROCESSED LED BLINKING 1 There is a command holding the gate open...

Page 37: ...SL SL DM Q409 Q400 O OMNI EXB Q401 Q006 Q410 Q254 UL Q255 NON UL Q408 Q402 1 2 HP Q403 1 HP Q404 Q005 O QCC OMNI Q013 Q018 Q027 Q025 Q237 Q028 Q021 Q030 Q016 Q015 Q014 Electronic Box Assembly A ELD N...

Page 38: ...elt DM and 1 HP Q237 Crank Input Q254 Cover HD Polyethylene Q329 Limit Switch Q400 Omni Main PCB Q401 Omni 1 Horsepower Board Q404 Omni Alarm Q407 Omni Motor harness 1HP Q408 Electronic Power Strip Q4...

Page 39: ...T S External Safety Loop Detectors Card Reader Outdoor Digital Lock Outdoor Digital Lock with Intercom Indoor Intercom Speaker Outdoor Intercom Speaker Three Push Button Remote Control System Key Stat...

Reviews: