16
User Manual
EN
The Battery and the Quadra Hybrid electronic is secured with an ATO 20 A fuse.
The unit and the LED Pilotlight are electronically protected against overheating and cut-outs.
The Battery topside includes transport pockets for two ATO 20 A fuses.
N.B. Remove the Battery fuse when you travel by air.
1.
Battery contacts
2.
Transport pocket for spare fuses
3.
Battery Fuse ATO 20 A
4.
Battery charge plug
fUse
Use only the original RQ Multi-Voltage Charger 19284. Other chargers may force technical problems. The RQ
charger indicates the charging status with a multicolored LED:
Yellow:
Charging in progress, 1.5 h for a discharged battery
Green:
Recharged;
NOTE: if the battery is disconnected or without the fuse the LED lights up
green as well!
No LED light:
Failure, contact the Elinchrom Service.
The 12 V / 3.6 A Battery can be recharged from any charge level, there is no Memory-Effect.
The number of flashes may vary from Battery to Battery (due to aging, recycling speed etc.)
Even new Batteries may vary; N.B. The full capacity of the Battery is available only after some
charge cycles. Used batteries may need to be recycled. Check your local regulations! Use only
the original Elinchrom Quadra Hybrid Battery.
Please read the separate Li-Ion Battery Box User Manual for detailed information, in case
Li-Ion Batteries are used!
1
2
1
2
3
4
baTTery excHange
➠
➠
1.
Push Button
2.
Security Lock
•
Place the Quadra Hybrid pack on a flat, dry and clean surface.
•
Simultaneously press the central security locks down before pressing on
the outer releases to separate the battery unit.
•
Place the new, charged Battery Box on a clean surface.
•
Place the Quadra Hybrid housing over the Battery Box.
•
Press smoothly down on the Quadra Hybrid pack until you hear two clicks
(left / right) activating the locking mechanism.
•
Check, that the Battery Box is well connected on both sides of the unit!
baTTery cHarging / fUses