2
3
1
Mains fuse
Modelling fuse
Mains switch
(Only tempered)
Mains socket
4
8 AT
4 AF
Mains Supply
With the MAINS SWITCH (3) switched off ("O" position), firmly push in the plug
of the original ELINCHROM mains cord into the mains socket (1).
Mains Switch
The switch should light up when the compact is switched on ("I" position).
(Switch off before removing the mains cord).
Troubleshooting
If the on/off switch (3) is ON ("I" position) but not illuminated,
switch off the unit and check the mains fuse (2).
If failed replace with the correct fuse and switch ON the unit.
This unit is protected by a thermal circuit breaker to avoid overheating.
Should this occur, the unit turns off automatically and cannot be fired.
After a break for cooling, the flash will be ready again for operation.
See page 11: Troubleshooting
This equipment is not user serviceable and contains high voltages which are dangerous.
In the event of failure, please return the unit to an authorized Elinchrom service station.
Mains Fuse
Standard type 5 x 20 mm, (use only tempered fuse)
8 AT (code 19022) for Style 100FX and Style 400FX
Note: Before exchanging a blown fuse, switch off the unit and remove mains cable. Depress and
turn the fuse holder anti-clockwise 1/8th, turn and remove it. If the new fuse blows immediately
upon reconnection, return the unit to an ELINCHROM service centre for a check-up.
(Please don't forget to check the correct rating of the fuse !).
Fuse for modelling light
Fast type 5 x 20mm, 4 AF
Switch off the unit and replace the blown fuse with a new one of the correct rating.
The fastblow fuse will protect the triac of the modelling lamp circuit, the lamp and therefore
the flash tube.
7