background image

4

 

• Transport the flash unit with care and only in its original packaging or another corresponding 

   packaging fit to protect it against knocks and jolts. 

• Transport only in complete discharged conditions. Wait a minimum 30 minutes after removing          

   from mains supply before packaging and transportation.

• Never drop the flash unit (danger of glass breakage) 

Power cable

To guarantee safe operation, use the cable supplied.

• The cable has to be HAR-certified or VDE-certified. the mark HAR or VDE will appear on the outer     

   sheat.

• The cable set must be selected according to the rated current for your flash unit.

• Do not use a spider box to connect one or more flash units.

!

• Flash systems store electrical energy in capacitors by applying high voltage.

• For your safety, never open or disassemble your flashes.

• Only an authorised service engineer should open or attempt to repair the units.

• Internal  defect  charge capacitors may explode whilst the unit is in use, neve

   switch on a proper working flash unit. 

According to safety regulations, we draw your attention to the fact that these 

electronic flash units are not designed for use outdoors, in damp or dusty conditions and should 

not be used after being exposed to sudden temperature changes causing condensation. They must 

always be connected to an earthed (grounded) mains supply.

On no account should any object be inserted into the ventilation holes.

The units may retain an internal charge for a considerable time even though disconnected from the 

power supply.

• Do not use in restricted areas (like hospitals, etc.).

• Do not use in explosive environnements.

• Flash tubes and modelling lamps in use are very hot!

• Never touch a flash tube or lamp before the unit cooled down and is disconnected from

   the mains (min 30mn).

• Do not fire flashes from short distance (less than 1m) directed to a person and avoid looking  

 

   directly into the flashlight!

• Keep (min 1m) distance to flammable materials.

• Keep generally distance to operating units.

Safety notice

Transport

Flash Tubes and Modelling lamps

Summary of Contents for FX 400

Page 1: ...English 190 260V elinca sa switzerland www elinchrom com Operating Manual Style FX 100 400 Elinca S A Style FX 01 01 2007 ENG 73276 Printed in Switzerland...

Page 2: ...ecycling CE marking 3 Safety notice and precaution 4 Operating instructions 5 Control Panel 6 Switch and Fuse 7 Modelling Light 8 Digital power display Photo cell 9 Synchronisation Wireless Remote con...

Page 3: ...he limits for a class B digital device pursuant to Part 15 of the FCC Rules and meets all requirements of the Canadian Interference Causing Equipement Regulations These limits are designed to provide...

Page 4: ...hatistheresultofnormaluse Anycomponentsnotreclaimed will be disposed of in a environmentally acceptable manner If you have any question on disposal please contact your local office or your local ELINC...

Page 5: ...may explode whilst the unit is in use neve switch on a proper working flash unit According to safety regulations we draw your attention to the fact that these electronic flash units are not designed f...

Page 6: ...ve cover note first turn the locking ring A as shown then rotate the black cap cover B in the same direction Fitting a reflector or accessory is the reverse of this action DO NOT operate the unit with...

Page 7: ...scharge indicator 8 Acoustic recharging signal Beep 9 Slave cell switch on off 10 Photocell receptor 11 Power adjustment in 1 10 f stops with ADF 12 Power adjustment in 1 10 f stops 13 Modelling lamp...

Page 8: ...ash will be ready again for operation See page 11 Troubleshooting This equipment is not user serviceable and contains high voltages which are dangerous In the event of failure please return the unit t...

Page 9: ...ximum Proportional modelling lamp is set when the position PROP is selected led is illuminated the light output is proportional to the selected flash power For all types of Style FX compact flash unit...

Page 10: ...harge system protected by a thermic switch To avoid overheating lower power settings of more than 2f stop can be discharged manually by releasing the flash with the Test touch button The photocell is...

Page 11: ...system could be defective Please contact and send to an authorized Elinchrom service Audible recharge signal Select the function with the touch pad 8 the green indicator appears Once recycled an acou...

Page 12: ...Style FX model 2 The switch 3 is lit the open flash ready is lighting up but does not function The flashtube in the flashhead may be faulty You cannot change the flashtube by yourself please return t...

Page 13: ...et 3 5 mm Socket for Plug In remote control Mains inlet socket and two fuses Mains and modelling Locking bayonet ring for accessory and reflector fitting Tilthead whit 5 8 inch stand socket Thermal sa...

Page 14: ...m 83 cm 26350 Translucent diam 85 cm 26371 Spots Zoom Spot 18 36 26481 Mini spot 26420 Stands Stand 85 235cm 30101 Stand Master 109 385 cm 30149B Bags Carrying bag for 2 mono compacts 33197 Carrying b...

Page 15: ...chrom com Downloads Product Registration i 14 Please return this registratioin card directly to Diese Registrierkarte bitte direkt zur cksenden an Veuillez retourner cette carte d enregistrement direc...

Page 16: ...www elinchrom com...

Reviews: