  Tri Disc 9 IR                                          Safety Precautions

Eliminator Lighting  -  www.eliminatorlighting.com  - Tri Disc 9 IR User Manual - Page 4

Eliminator Lighting  -  www.eliminatorlighting.com  - Tri Disc 9 IR User Manual - Page 3

•   To reduce the risk of electrical shock or fire, do not expose this unit  

   rain or moisture

•   Do not spill water or other liquids into or on to your unit.

•   Do not attempt to operate this unit if the power cord has been   

   frayed or broken. Do not attempt to remove or break off the ground 

   prong from the electrical cord. This prong is used to reduce the risk  

   of electrical shock and fire in case of an internal short.

•   Disconnect from main power before making any type of connection.

•   Do not remove the cover under any conditions. There are no user  

   serviceable parts inside.

•   Never operate this unit when it’s cover is removed.

•   Never plug this unit in to a dimmer pack

•   Always be sure to mount this unit in an area that will allow proper  

   ventilation. Allow about 6” (15cm) between this device and a wall.

•   Do not attempt to operate this unit, if it becomes damaged.

•   This unit is intended for indoor use only, use of this product out`  

   doors voids all warranties.

•   During long periods of non-use, disconnect the unit’s main power.

•   Always mount this unit in safe and stable matter.

•   Power-supply cords should be routed so that they are not likely to  

   be walked on or pinched by items placed upon or against them,  

   paying particular attention to the point they exit from the unit. 

• Cleaning -The fixture should be cleaned only as recommended by  

  t he manufacturer. See page 25 for cleaning details.

•   Heat -The appliance should be situated away from heat sources  

   such as radiators, heat registers, stoves, or other appliances (inclu-

   d ing amplifiers) that produce heat.

•   The fixture should  be serviced by qualified service personnel when:

    A. The power-supply cord or the plug has been damaged.

    B. Objects have fallen, or liquid has been spilled into the appliance.

    C. The appliance has been exposed to rain or water.

    D. The appliance does not appear to operate normally or exhibits a  

         marked change in performance.

P

ower Supply:

 The Tri Disc 9 IR contains a automatic voltage switch, 

which will auto sense the voltage when it is plugged into the power 

source. With this switch there is no need to worry about the correct 

power voltage, this unit can be plugged in anywhere.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To ensure proper DMX data transmission, when using several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Tri Disc 9 IR can be controlled via DMX-512 protocol. The Tri Disc 9 

IR has 7 DMX channel modes, please see pages 12-13 for the different 

modes. The DMX address is set on the back panel of the Tri Disc 9 IR. 

Your unit and your DMX controller require a standard 3-pin XLR connec-

tor for data input and data output (Figure 1). We 

recommend Accu-Cable DMX cables. If you are 

making your own cables, be sure to use standard 

110-120 Ohm shielded cable (This cable may be 

purchased at almost all pro lighting stores). Your 

cables should be made with a male and female 

XLR connector on either end of the cable. Also 

remember that DMX cable must be daisy chained 

and cannot be split.

  Tri Disc 9 IR                                                              Set Up

Figure 1

Summary of Contents for TRI DISC 9 IR

Page 1: ...ed during shipping If the carton appears to be damaged carefully inspect your fixture for any damage and be sure all accessories necessary to operate the unit has arrived intact In the case damage has...

Page 2: ...y or exhibits a marked change in performance Power Supply The Tri Disc 9 IR contains a automatic voltage switch which will auto sense the voltage when it is plugged into the power source With this swi...

Page 3: ...n a 3 pin DMX line When inserting stan dard 5 pin data cables in to a 3 pin line a cable adaptor must be used these adaptors are readily available at most electric stores The chart below details a pro...

Page 4: ...de speed to F 00 This means the color fade is off and the fixture will now color change at the speed you have set To run the fixture in color fade reverse Tri Disc 9 IR Operating Instructions the inst...

Page 5: ...ge 11 for the controls and functions 1 Plug the fixture in and press the MODE button until dXX is dis played XX represents on or off 2 Press the SET UP button until IrXX is displayed XX repre sents ei...

Page 6: ...ress 245 Press S 2 4 5 7 SL SA Slave Sound Active This button lets you switch between Slave mode in a Master Slave configuration and Sound Active mode When the fixture is in Sound Active mode use the...

Page 7: ...ue Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 4 MASTER DIMMER 0 255 0 100 Channels 1 2 and 3 will not work when Channel 4 is being used Channel Value Function 1 RED 1 255 0 100...

Page 8: ...e speed of the programs When using Channel 6 values 136 255 Channel 5 will control the sound sensitivity Sound sen sitivity control will start working after Channel 5 is past the DMX value of 31 Chann...

Page 9: ...out the fuse holder Remove the bad fuse and replace with a new one The fuse holder also has a holder for a spare fuse Tri Disc 9 IR Fuse Replacement With this feature you can connect the fixtures to...

Page 10: ...Dimensions 10 5 L x 10 W x 3 5 H 263 x 250 x 88mm Colors RGB Color Mixing DMX Channels 7 DMX Modes 1 Channel Mode 2 Channel Mode 3 Channel Mode 4 Channel Mode 5 Channel Mode 6 Channel Mode 7 Channel...