On DT system,every apartment must assign a unique identification called
User Code
.
There are two setting modes for address setting,DIP switcher and manual input .
Setting user code
In default mode,when receiving a call,the master and slave monitors will ring at the same
time,and just the master monitor can display the image while the slave monitors will not. But the
settings can be changed,you can set the master monitor and all the slave monitors to panel on
at the same time when being called.
•
Click “ Slave Panel On When Being Called” item,when “
“ symbol is displayed in the
frame , the setting is activated.
•
Click the item again to cancel.
Setting slave monitor panel on
This monitor is assigned with DIP setting instructions.
On Address setting page,select DIP Switcher Set Address setting mode firstly, then touch
icon, total 32 DIP codes will be displayed.
DIP Switcher Set Address
The DIP switches are used to set the user code for each monitor.Total 6 bits can be configured.
•
Bit-1 to Bit-5 are used for user code setting. The value range is from 0 to 31, which have 32
different codes for 32 apartments.
•
When multi monitors need to be installed in one apartment, these monitors should use the
same user code, and the master/slave mode should be set on the monitor. (Details refer to
the section of
Setting Slave Monitor
)
•
Bit-6 is bus line terminal switch, which should be set to “ON” if the monitor is at the end of
bus line, otherwise be set to “OFF”.
ON(1)
=
OFF(0)
=
ON
ON
ON
DIP
1 2 3 4 5 6
Bit state
Setting
Bit state
Setting
1 2 3 4 5
6
ON
DIP
1 2 3 4 5
6
ON
DIP
When monitor is not
at the end of bus line.
When monitor is at
the end of bus line.
Bit-6 switch setting