background image

 

Summary of Contents for EDC-2600

Page 1: ......

Page 2: ...I This product is always protected when you connect the power supply must be connected to ground included Class I is a product in which the protection against electric shock does not rely on basic insulation only but which includes an additional safety precaution in such a way that means are provided for the connection of the product to the protective ground conductor in the fixed wiring of the in...

Page 3: ...ever for possible errors or omissions or for any consequences resulting from the No use of the information contained herein EDC 2600 reserves the right to make changes in its products or product specifications at any time and without prior notice and is not required to update this documentation to reflect such changes Do not modify this equipment without authorization of the manufacturer If this e...

Page 4: ...standard EN 60601 1 2 2007 Everybody who connects additional equipment to the signal input part or signal output part configures a medical system and is therefore responsible that the system complies with the requirements of the system standard EN 60601 1 1 2001 If in doubt consult the technical service department or your local representative For EU Countries The following mark the name address of...

Page 5: ...SYMBOLS Symbol Description Alternating current General warning find the Annex Off On DO NOT dispose waste Manufacturer Manufacturing date Authorized Europe representative ...

Page 6: ...e or electric shock may occur WARNING All cables must be connected or disconnected after turn off the power DO NOT touch cables with wet hands This may result in serious injuryor death due to electric shock WARNING Turn off the switch and disconnect the power cable from AC immediately and ask for help to the purchased store if followings occur In case of smoke odor and noise occur In case of spill...

Page 7: ...FETY INFORMATION 4 GENERAL SAFETY INFORMATION 6 1 Features 9 2 Introductions for use 10 3 Functions of each parts 11 4 Installation 18 5 Operation 20 6 Operation mode 21 7 Menu mode 22 8 Program mode 25 9 Maintenance 26 10 Specifications 28 ...

Page 8: ...or feature A high performance Polarizing filter allows Polar test in any installation distance Contrast adjustment feature for contrast sensitivity test that eases visual acuity test for all patients especially cataract patient is available Black white reversal feature offers convenient test patients who had Lasik surgery For prompt and accurate test EDC 2600 is usable alone with remote control an...

Page 9: ...600 In case of connecting EDC 2600 with another or moving please follow the guides of technician or service agent Please place it flat floor Exterior lighting affects the test Use the instrument in an appropriate optometry room Keep the monitor clean to avoid incorrect measurement and check the monitor before use Shocks may bring internal or external damage Handle it with care DO NOT expose EDC 26...

Page 10: ...dy cradle for wall mount remote control and accessories Explanations and functions of each component are as followings 2 1 Main body The main body of EDC 2600 is the most significant part and installed on the cradle State LED Remote control receiver Figure 1 Front Figure 2 Rear ...

Page 11: ... Serial cable port Power switch USB port Adapter connector Figure 3 Side I O ...

Page 12: ...ht the bolts to assemble the cradle and main body Serial cable port Connects digital refractor and connected chart cable Power switch A switch for power It may run in about 8seconds after power on USB port Uses to connecting USB flash drive and supports 2 ports Adapter connector Supplies power by connecting the adapter Before the connection separate power cable and outlet Chart 1 Main body ...

Page 13: ...p button 4 Program button 2 Power button 1 IR Sensor 7 Arrows 5 Slide button 6 Mask button 3 1 Remote control Turns LCD chart on and off with remote control and changes display for test Figure 4 Remote control ...

Page 14: ...ckside when don t use unit for a long time 3 Set up button Set the menu for user s convenience 4 Program button PROGRAM A B Select program A or B NEXT Go next page PREV Go previous page 5 Slide button Starts or ends the Slide mode 6 Mask button Set vertical horizontal single characteristic mask 7 Arrows Moves mask or to the next chart Chart 2 Remote control ...

Page 15: ...cessories of EDC 2600 are composed standard products and optional products Optional Optional Figure 5 Accessories Descriptions Function Q ty Batteries 1 5V AA size batteries 2 Adapter A power supplier to the main body 1 Power cable A power supplier to the main body 1 Serial cable A cable connects with digital refractor for use 1 Wall bracket A bracket fixes the main body on the wall 1 Polarized gl...

Page 16: ...3 1 Parts list ID Q ty Descriptions 1 1 Wall plate 2 1 Adapter bracket 3 2 Safety bolt A1 4 M4x8mm bolt 4 M4x12mm bolt A2 4 M5x8mm bolt 4 M5x12mm bolt A3 4 M5 washer B1 2 Long bolt B2 2 Wall anchor B3 2 Long bolt washer ...

Page 17: ...ashers B3 to tight wall plate on the wood stud CAUTION DO NOT tight bolts excessively B Concrete wall mounting 1 Place wall plate on the wall to mark two mounting holes 2 Drill mounting holes 60mm deep with 10mm drill bit 3 Insert anchors B2 on the holes and tight long bolts B1 and long bolt washers B3 tightly CAUTION DO NOT tight bolts excessively ...

Page 18: ... after placing adapter bracket behind the monitor closely 2 Attach M5 Washer A3 by tighten bolts A1 A2 CAUTION DO NOT tight bolts excessively Stage 3 1 Slide the adapter bracket 2 into wall plate 1 2 Tight safety bolt 3 to fix the monitor ...

Page 19: ... mode Press Set Up on the remote control to enter set up mode Detailed information is on Chapter 7 Set up Slide mode Press Slide on the remote control to enter slide mode Detailed information is on Chapter 3 and 6 Slide mode Visual acuity chart Visual acuity charts are composed three categories with standard chart Landolt ring Snellen character chart 1 Number English character and character chart ...

Page 20: ...chart Detailed astigmatoscopy chart with cross cylinder lens Balance test chart Binocular balance test chart Red green background at character chart Worth 4 Dot chart Shober chart ETDRS chart Dyslexia chart Prescribed prismatic chart to correct strabismus Red LED with Maddox rod Aniseikonia test chart Prescribed prismatic Cross chart to correct strabismus ...

Page 21: ...en polarized Pointer chart Von Grafe chart Color blindness test chart Red LED for Maddox Rod Retinal abnormality test chart Program mode EDC 2600 supports two programs Each program can have 28 charts and allows using them in order It is easy to edit and use on visual acuity test Detailed information is on Chapter 8 Program mode ...

Page 22: ...e mode Use this mode when EDC 2600 is used alone Performs all operations used by the remote control of EDC 2600 Supports program A B Supports slide 6 2 Refractor mode Digital refractor link mode Use this mode after link with digital refractor It changes charts for visual acuity test with digital refractor panel and menu mode and slide mode are operated by the remote control only Does not support p...

Page 23: ...Set up on the remote control at test mode Selecting menu Press Next or Prev on the remote control to select menu Changing value Press arrows on the remote control to set the value Saving changed value Press Next or Prev on the remote control to move to Save Press Set up to save changed value and go back to test mode ...

Page 24: ...t ETDRS Landolt Snellen Set Landolt or Snellen as standard chart Child Chart Set chart type for children TYPE 1 Basic image test chart TYPE 2 Symbol test chart RG Polar Setting changes depending on the product type Red Green Regular model Polarizing chart is unavailable during Polar mode Polar Polarizing model Both modes are available Cross Type Set the Cross chart by left right segmented directio...

Page 25: ...t respectively 11 different channels are available How to alter channel 1 It s valid only on normal chart mode 2 Press button on R C five times and press button in order 3 It shows current remote control channel as CH 1 on a bottom of right side of panel 4 To change channel press pushing button 5 To see current channel press button once again it shows CH 2 6 To change set up press button it d be i...

Page 26: ...2 Copy the latest version EDC 2600 No extension into USB 3 Move Cursor to and then press button S W Update would be begun automatically If File System in USB is not proper or the file for updating does not exist it shows The Update File doesn t exist 4 It shows Ver X XX on a top of right side if it s done normally ...

Page 27: ...and polarizing model Red Value 0 255 Brightness of red value changes in 5 units Green Value 0 255 Brightness of green value changes in 5 units Background 0 255 Background brightness value changes in 5 units Changed value will be applied after click Set Color ...

Page 28: ...ng test chart by the frequency Program A Program B Other charts can be applied as type A or B Move the cursor to the test chart and press Set Up on the remote control to register Press Clear for defaulting applied charts on the bottom It appears upper left when Program mode is set up from Test mode ...

Page 29: ...ar as slide Update button Copy and register images by inserting the USB flash drive Delete button Delete all images Default button Delete all images and default We recommend to modify the values on Menu mode after the system becomes familiar ...

Page 30: ...A Twice Program B Three times Cancel the program Name and number of current and total programmed chart appears on the upper left as shown below Figure 5 Running program Change program step Press NEXT to move next step Press PRV to move previous step Close Program mode Click PROGRAM A B to close the program 8 2 Program editing Current type and order of the chart can be edited at Program under Set U...

Page 31: ...ician or service agent if the EDC 2600 is still off Remote control does not work Replace the batteries two1 5V AA size batteries Clean the receiver on the main body and the transmitter on the remote control If the remote control still does not work contact technician or service agent 9 2 Cleaning instrument Exterior This instrument must clean DO NOT clean it with flammables such as thinner and ben...

Page 32: ...C 2600 has problem Inform followings based on product information label Model name EDC 2600 Serial number Polarized 10 characteristics on product information label Serial number Non polarized 10 characteristics on product information label Figure 6 Product information label ...

Page 33: ...Distance 1 5m 7 0m Changes into 0 25 meter unit Control device IR remote control wireless Digital refractor wired Screen saver Power save Chart show 5secs 10secs 30secs Screen saver timeout 3mins 5mins 10mins 20mins Product specifications Main body 575 W x 370 H x 43 D mm 4 kg Remote control 64 W x 195 H x 20 D mm 110 g Power supply DC 5V 5A Adapter Power consumption Max 15W Accessories Cradle Wal...

Page 34: ...nt Warning for EMC Minimum distance from RF communications Portable RF communications equipment including peripherals such as antenna cables and external antennas should be used no closer than 30 cm 12 inches to any part of the EDC 2600 including cables specified by the US OPhthalmic Otherwise degradation of the performance of this equipment could result Cables and accessories Use of accessories t...

Page 35: ...80 AM at 1 kHz Immunity to Proximity Fields from RF wireless Communications Equipment IEC 61000 4 3 2006 A1 2007 A2 2010 Enclosure Table 9 in IEC 60601 1 2 2014 Electrical Fast Transient Burst Immunity IEC 61000 4 4 2012 AC Mains 2 kV 100 kHz repetition frequency Surge Immunity IEC 61000 4 5 2005 AC Mains Line to Line 0 5 kV 1 kV Line to Ground 0 5 kV 1 kV 2 kV Immunity to Conducted Disturbances I...

Page 36: ...ose of product COMPANY US Ophthalmic LLC ADD 9990 NW 14 ST STE 105 Doral FL 33172 Tel 1 888 881 1122 Fax 786 621 1842 This instrument has alkaline battery that may pollute environment by disposal or negligence Before the disposal contact professional disposal company or purchased store ...