Product Features
- 8 -
5
Product Features
The universal ELGO position indicator Z58-600 is suitable for detecting
lengths and positions. The device has 2 programmable pre-selections in
order to control 2 internal normally open relays.
Both conventional incremental encoders and incremental or absolute
ELGO measuring systems can be connected as input signals. It is there-
fore a universal device which can visualize the information of numerous
ELGO standard measuring systems.
With the Z58-600, ELGO is able to offer a complete solution concerning
signal detection and visualization.
The predecessor type Z54 can be replaced by Z58 (except for a few
special devices). Please consider the pin assignment during Z54 re-
placement, because with Z58 additional plugs for news encoder types
are available.
Essential Features:
Power supply:
- 24 VDC (standard)
- 115/230 VAC with external ELGO power pack NG24.0 possible
- 115 VAC-supply alternatively available when order type Z58-654-115-X (restrictions
- 230 VAC-supply alternatively available when order type Z58-654-230-X (restrictions
Standardly with panel mounting housing (cut-out = 93 x 67 mm)
Optionally with built-on housing for surface mounting available
Installation depth = 73 mm (110 mm inclusive D-SUB connector)
RS232 interface for transmission of the actual value
All connections are pluggable
5.1
Compatible Measuring Systems
Table 1: Compatible Measuring Systems
Measuring principle Compatible Measuring Systems
Incremental
Conventional HTL- and TTL rotary encoders as well as the unguided ELGO linear
encoders LMIX, EMIX, DMIX, GMIX, RMIX or guided FMIX and PMIX systems
Absolute
ELGO EMAX (unguided) and FMAX (guided). FMAX calibration see chapter
5.2
Digital Inputs
The unit has 3 external inputs for triggering the setting functions (reset, reference and tool-offset).
These inputs are available at the 6-pin Phoenix connector S2 and have the following properties:
Characteristic: PNP, active high
Switching voltage: +24 VDC
Input current: max. 10 mA