Design and Functions
- 18 -
9.4
Parameter List
Table 4: Parameter list
Parameter Function
Range
Default Setting
P 00
reserved for test purposes
- - - - - -
P 01
Counting direction (0 = up / 1 = down)
0, 1
0
P 02
no function / reserved
- - - - - -
P 03
Decimal place
0, 1, 2, 3
1
P 04
Actual value memory
(0 = enabled / 1 = disabled)
0, 1
0
P 05
Front keys (0 = enabled / 1 = disabled)
0, 1
0000
P 06
Edge evaluation (0 = x 1, 1 = x 2, 2 = x 4)
0, 1, 2
0
P 07
Measuring system selection:
(0 = A/B Encoder, 1 = RS422 Encoder,
2 = EMAX/FEMAX, 3 = FMAX,)
0, 1, 2, 3
0
P 08
Multiplication factor
00.0001 ... 99.9999
01.0000
P 09
Reference value
−99999.9 ... +99999.9
00000.0
P 10
Tool-offset
−99999.9 ... +99999.9
00000.0
P 11
Saw blade thickness
0 ... +99999.9
00000.0
P 12
Preset limit relay 1 (min)
−99999.9 ... +99999.9
00000.0
P 13
Preset limit relay 2 (max)
−99999.9 ... +99999.9
00000.0
P 14
Display brightness
0 ... 9
5
P 15
no function / reserved
- - - - - -
P 16
Load default parameters (0 = no / 1 = yes)
0, 1
0
P 17
Measurements unit (0 = mm / 1 = inch)
0, 1
0
P 18
no function / reserved
- - - - - -
P 19
no function / reserved
- - - - - -
P 20
Analog output (minimum value)
−99999.9 ... +99999.9
00000.0
P 21
Analog output (maximum value)
−99999.9 ... +99999.9
00000.0
P 22 ... 98 no function / reserved
- - - - - -
P99
Software-Version
XX.XX
9.5
Load Default Parameters
Parameter P16 can be used to reset all parameters to their default settings. For this purpose set P16 to „1“,
press
F
+
Incr/Abs
for 3 s at the same time and switch the power of the Z58 indicator 1 x OFF and ON again.