background image

4. Audio Test Method and Specifications

A. Test Method

Power Required 

6V DC 400mA (one for Tx, one for Rx)

Rx Resistive Load 

10 KΩ

Audio Analyzer Filters 

AES17 LPF “IN” unless otherwise specified

Tx Input Conditions 

997Hz @ -3.5 dBV = Full Scale Input

Rx Output Level 

Maximum * (Set by Volume Control)

Distance Apart 

No closer than ~1 m **

Notes 

• Nodes should be tested on ESD safe surfaces and ideally elevated above surface on ESD safe mounts.
• Cables should be as far away as possible from equipment that can introduce noise into nodes. (i.e. CRT monitors, AC Transformers, 
etc )
• Batteries can be used to eliminate 50/60Hz noise.

• The antenna orientation shown is for audio testing.  A different antenna orientation may be better suited for maximum RF range 
performance.

* Evaluation Kits are shipped with output level set to MAX.
** To avoid RF swamping.

www.ElevenEngineering.com 

   

HT-222 Evaluation Kit Instructions 

 

         DO4927| 

2009.11.05

Page 3/4

Summary of Contents for HT-222

Page 1: ...plication firmware implements a number of useful user interface features such as LED blinking and push button volume control It also supports customizable settings which can be loaded into the modules over Two Wire Serial Interface TWSI or via the XPD programming interface These settings are stored in a Parameter Page which is a file stored in non volatile memory on the HT 222 module This section ...

Page 2: ...io level to rise above the threshold Normal Default Setting 78 seconds F Reset Button Pressing the Reset button will reset the entire module This button is sometimes useful when downloading new firmware G XPD Port Interface The XInC Programming and Debugging XPD port is used to download firmware hex files to the HT 222 module using an XPD Programming Module available from Eleven Engineering For mo...

Page 3: ... ESD safe surfaces and ideally elevated above surface on ESD safe mounts Cables should be as far away as possible from equipment that can introduce noise into nodes i e CRT monitors AC Transformers etc Batteries can be used to eliminate 50 60Hz noise The antenna orientation shown is for audio testing A different antenna orientation may be better suited for maximum RF range performance Evaluation K...

Page 4: ... Antenna orientation is important to overall RF range performance Layout of the testing space affects RF performance Reflections of the RF can cause interference Obstacles such as the tester s body walls and cubicles can affect the range wherever possible keep node antennas in line of sight Other RF devices operating in the 2 4GHz spectrum can affect the RF performance such as microwaves wireless ...

Reviews: