The table below defines the representation and description
of situations used in these operating instructions for
situations in which damage can occur to the product or
indicates important facts, conditions, tips and information.
Symbol Signal word Meaning
ATTENTION This symbol warns
against possible damage
to property or equipment.
IMPORTANT This symbol indicates
important facts and states
as well as referring to
further information in
these operating and
assembly instructions.
It also refers to certain
additional instructions,
which provide additional
information or help you
to carry out a procedure
more simply.
Symbol indicating
successful grounding
with protection class I
(Protective conductor
system)
Fig. 3 Notation for damage to property and additional
information
The following example illustrates the basic structure of a
safety note:
SIGNAL WORD
Type and source of danger
Explanation of type and source of danger
►
Measures to avoid the danger
4
Product description
The RolMotion M is an electromechanical tubular drive for
roller blinds and textile sun protection. During operation it
executes radial movements.
Commissioning of the RolMotion M with
elero
assembly
cable or radio transmitter for setting various functions.
Blind protection with free travel (torque limiting).
Relief function for the blind (blind protection).
Cyclical reference runs compensate for changes in the
winding behaviour of the roller blind slats.
In addition to the usual travel profile (travel profile
standard), the RolMotion M drive also has a reduced-
speed travel profile (motion travel profile).
Slow travel when placing the roller blind slats.
Slow travel with timed release.
4.1 Product contents
Drive with safety instructions and operating instructions and
any additional components and accessories according to
the order confirmation or delivery note.
4.2 Accessories
Connection and assembly cable, adapter sets, motor
bearing, ProLine control units, sensors, receivers.
5
Assembly
WARNING
Important safety instructions
Observe all assembly instructions. Incorrect assembly can
lead to serious injuries.
►
Commissioning of the RolMotion M with elero assembly
cable for setting various functions.
►
Before installation, all cables and components that are
not required and all facilities that are not needed for
operation with a power drive are to be disabled.
►
The required components are: drive, connection
and assembly cable, motor bearing, adapter sets, if
necessary rigid shaft connectors, sensors, control
devices, receivers.
►
If components are not delivered with the drive, these can
be identified via our catalogue “Drives and control units
for intelligent building technology” in the relevant valid
version. Further details can be found on our website
under “Contact - dealer search” and “Contact - contact
persons for specialist companies”.
►
The rated torque and rated operating time must be
suitable for the properties of the driven part (the blind).
►
The coupling of the drive with the powered part is
described in the section “Mechanical fastening”.
CAUTION
Risk of injuries due to hot surfaces.
The drive will heat up during operation, the drive casing
can become hot. Skin burns are possible.
►
Wear personal protection equipment (protective gloves).
Triggered by a possible material fault, knocks or impact
injuries may arise due to a gear fracture, burring fracture or
a coupling defect.
►
Suitable materials have been used for the engineering
design and random sample testing by means of a double
load test has been performed in accordance with
DIN EN 60335-2-97.
Risk of injury due to knocks or impact triggered by motor
bearings that are incorrectly mounted or engaged. Hazard
due to insufficient stability or steadiness and accumulated
energy (gravity).
►Selection of motor bearing by torque specifications.
►
The drive must be protected with all the enclosed safety
devices.
►
Check for correct engagement on motor bearing and the
correct screw tightening torques.
WARNING
Risk of injury due to electric current.
Risk of electric shock.
►
Always have electrical work carried out by an authorised
electrician.
Risk of injury due to electric current.
Possible danger due to parts that are faulty becoming
energised.
►
The drive falls under protection class I (protective
conductor system). All housing parts of the drive capable
of conducting electricity are connected with the protective
©
elero
GmbH
EN | 3
Safety | Product description | Assembly