elero RevoLine L RolTop L80 User Manual Download Page 6

17.6.9 Variant D:  Upper end position freely  

adjustable, fixed lower limit stop 

Variant D:  Upper end position freely adjustable, 

fixed lower limit stop 

① 

From a middle Venetian blind position with the as-

sembly cable, push the 

UP 

button ▲ until the Vene-

tian blind has reached the desired end position. 
The drive starts, stops briefly and then moves on 

(while the button  is pushed). 
Correction is possible with the buttons  ▲ and ▼ . 

② 

Press the 

DOWN

 button ▼ until the drive stops 

automatically. 
The upper end position has been set. 

③ 

Press the 

DOWN

 button ▼ again until the Venetian 

blind has reached the lower end stop (run to lower 

end stop). 
The drive starts, stops briefly and then moves on 

(while the DOWN button  ▼ is pushed).
The drive switches off automatically when the lower 

limit stop is reached. 

④ 

Press the 

UP

 button 

▲ 

 until the drive stops 

automatically.

  

The lower end position has been set. 

Optional:

 Activation of the relief function for the 

lower stop; see chapter 5.6.3 

 

Setting of the end positions variant D is now complete. 

Fig. 11  End position setting Variant D: 

18  Troubleshooting 

Problem /  

Error 

Possible 

cause 

Cure 

 

Remedy 

•  Drive stops 

during travel 

•  End positions 

are not set 

•  Drive is in 

setting mode 

•  Set end posi-

tions 

•  Drive stops 

after a short 

time 

•  End position 

programmed 

•  Sluggish 

shutter 

•  Set second 

end position 

•  Check smooth 

running of the 

Venetian blind 

•  Drive runs only 

in one direction 

•  Connection 

error 

•  Check connec-

tion 

•  Drive not 

responding 

•  No mains 

voltage 

•  Temperature 

limiter has 

tripped 

•  Check mains 

voltage 

•  Allow drive to 

cool 

•  Drive does not 

learn any end 

positions 

•  Random travel  

 

 

•  Travel to end 

position or limit 

stop too short 

•  Delete end 

positions 

Reset end 

positions 

•  Drive must run, 

stop briefly 

and run on 

(while a button 

is pushed at 

the assembly 

cable). 

Fig. 12  Error search at the RolTop 

6 | EN  

© 

elero

 GmbH

 

Setting the end positions and the relief | Troubleshooting 

17.6.7 Variant B:  Fixed upper limit stop / lower  

end position freely adjustable 

Variant B:  Fixed upper limit stop / lower end posi-

tion freely adjustable 

①  

From a middle Venetian blind position with the 

assembly cable, push the 

UP 

button ▲ until the 

Venetian blind has reached the desired end position 

(run to the upper stop). 
The drive starts, stops briefly and then moves on 

(while the UP button  ▲ is pushed). 
The drive switches off automatically when the upper 

limit stop is reached. 

②  

Press the AB button ▼ until the drive stops auto-

matically. 
The upper end position has been set. 

Optional:

 Activation of the relief function for the 

upper stop; see chapter 5.6.2 

③   

Press the AB button ▼ again until the Venetian blind 

has reached the desired lower end stop. 
The drive starts, stops briefly and then moves on 

(while the button  is pushed). 
Correction is possible with the buttons  ▲ and ▼ . 

 

Press the AUF button ▲  until the drive stops auto-

matically. 

Setting of the end positions variant B is now complete. 

Fig. 9    End position setting Variant B: 

17.6.8 Variant C: Fixed upper and lower limit stop 

Variant C: Fixed upper and lower limit stop 

① 

 

From a middle Venetian blind position with the 

assembly cable, push the 

UP 

button ▲ until the 

Venetian blind has reached the desired end position 

(run to the upper stop). 
The drive starts, stops briefly and then moves on 

(while the UP button  ▲ is pushed). 
The drive switches off automatically when the upper 

limit stop is reached. 

②  

Press the AB button ▼ until the drive stops auto-

matically. 
The upper end position has been set. 

Optional:

 Activation of the relief function for the 

upper stop; see chapter 5.6.2 

③ 

Press the AB button ▼ again until the Venetian blind 

has reached the lower end stop (run to lower end 

stop). 
The drive starts, stops briefly and then moves on 

(while the DOWN button  ▼ is pushed). 
The drive switches off automatically when the lower 

limit stop is reached. 

  

Press the AUF button ▲  until the drive stops auto-

matically. 
The lower end position has been set. 

Optional:

 Activation of the relief function for the 

lower stop; see chapter 5.6.3 

Setting of the end positions variant C is now complete. 

Fig. 10  End position setting Variant C: 

Summary of Contents for RevoLine L RolTop L80

Page 1: ...g Instructions refer to the laws and regulations currently applicable in Germany All instructions in the Operating Instructions shall be ob served without limitation and at any time Beside the safety...

Page 2: ...the elero drive com putation program http elero de antriebsberechnungsprogramm Further fields of application have to be arranged with the manufacturer elero GmbH Antriebstechnik see Address The operat...

Page 3: ...WARNING Danger of injury due to electric current Electric shock possible Electrical work can only be performed by an authorized electrician Danger of injury due to electric current Hazardous possibly...

Page 4: ...the motor tube Look for an axial clearance 1 2 mm Installation in profile tubes Insert the drive with a suitable adapt er and traction ring into the profile tube Lay the motor cable protected in or de...

Page 5: ...al discharge function is lost Important The Venetian blind is adjusted only after a complete and uninterrupted access and exit to the blind Changing Deleting the end positions 1 From a middle Venetian...

Page 6: ...stop lower end position freely adjustable Variant B Fixed upper limit stop lower end posi tion freely adjustable From a middle Venetian blind position with the assembly cable push the UP button until...

Page 7: ...t 5 minutes after deactivation for the motor to cool down and the capaci tors to lose their voltage Use suitable tested and stable climbing aids when per forming disassembly work above body height All...

Page 8: ...er consumption W 118 140 200 270 300 Shaft diameter mm 50 Protection class IP 44 Limit switch range turns 40 Operating duration min S2 5 4 5 4 Length A mm 478 480 530 540 530 540 560 Length B mm 460 4...

Page 9: ...0 50 50 50 50 Rated torque Nm 1 5 3 5 5 8 10 12 12 Rated speed 1 min 70 30 30 17 17 17 17 11 Rated current A 0 55 0 55 0 73 0 55 0 73 0 55 0 73 0 55 Rated power consumption W 130 130 168 130 168 130 1...

Page 10: ...523 462 513 523 512 Weight kg 2 2 1 9 2 2 2 3 Operating environment temperature C 20 to 60 Conformity Emission sound pressure level dBA 70 Protection class I Plug in connecting cable m 2 0 Item numbe...

Reviews: