![elero RevoLine L RolTop L80 User Manual Download Page 6](http://html1.mh-extra.com/html/elero/revoline-l-roltop-l80/revoline-l-roltop-l80_user-manual_2388031006.webp)
17.6.9 Variant D: Upper end position freely
adjustable, fixed lower limit stop
Variant D: Upper end position freely adjustable,
fixed lower limit stop
①
From a middle Venetian blind position with the as-
sembly cable, push the
UP
button ▲ until the Vene-
tian blind has reached the desired end position.
The drive starts, stops briefly and then moves on
(while the button is pushed).
Correction is possible with the buttons ▲ and ▼ .
②
Press the
DOWN
button ▼ until the drive stops
automatically.
The upper end position has been set.
③
Press the
DOWN
button ▼ again until the Venetian
blind has reached the lower end stop (run to lower
end stop).
The drive starts, stops briefly and then moves on
(while the DOWN button ▼ is pushed).
The drive switches off automatically when the lower
limit stop is reached.
④
Press the
UP
button
▲
until the drive stops
automatically.
The lower end position has been set.
Optional:
Activation of the relief function for the
lower stop; see chapter 5.6.3
Setting of the end positions variant D is now complete.
Fig. 11 End position setting Variant D:
18 Troubleshooting
Problem /
Error
Possible
cause
Cure
Remedy
• Drive stops
during travel
• End positions
are not set
• Drive is in
setting mode
• Set end posi-
tions
• Drive stops
after a short
time
• End position
programmed
• Sluggish
shutter
• Set second
end position
• Check smooth
running of the
Venetian blind
• Drive runs only
in one direction
• Connection
error
• Check connec-
tion
• Drive not
responding
• No mains
voltage
• Temperature
limiter has
tripped
• Check mains
voltage
• Allow drive to
cool
• Drive does not
learn any end
positions
• Random travel
• Travel to end
position or limit
stop too short
• Delete end
positions
Reset end
positions
• Drive must run,
stop briefly
and run on
(while a button
is pushed at
the assembly
cable).
Fig. 12 Error search at the RolTop
6 | EN
©
elero
GmbH
Setting the end positions and the relief | Troubleshooting
17.6.7 Variant B: Fixed upper limit stop / lower
end position freely adjustable
Variant B: Fixed upper limit stop / lower end posi-
tion freely adjustable
①
From a middle Venetian blind position with the
assembly cable, push the
UP
button ▲ until the
Venetian blind has reached the desired end position
(run to the upper stop).
The drive starts, stops briefly and then moves on
(while the UP button ▲ is pushed).
The drive switches off automatically when the upper
limit stop is reached.
②
Press the AB button ▼ until the drive stops auto-
matically.
The upper end position has been set.
Optional:
Activation of the relief function for the
upper stop; see chapter 5.6.2
③
Press the AB button ▼ again until the Venetian blind
has reached the desired lower end stop.
The drive starts, stops briefly and then moves on
(while the button is pushed).
Correction is possible with the buttons ▲ and ▼ .
④
Press the AUF button ▲ until the drive stops auto-
matically.
Setting of the end positions variant B is now complete.
Fig. 9 End position setting Variant B:
17.6.8 Variant C: Fixed upper and lower limit stop
Variant C: Fixed upper and lower limit stop
①
From a middle Venetian blind position with the
assembly cable, push the
UP
button ▲ until the
Venetian blind has reached the desired end position
(run to the upper stop).
The drive starts, stops briefly and then moves on
(while the UP button ▲ is pushed).
The drive switches off automatically when the upper
limit stop is reached.
②
Press the AB button ▼ until the drive stops auto-
matically.
The upper end position has been set.
Optional:
Activation of the relief function for the
upper stop; see chapter 5.6.2
③
Press the AB button ▼ again until the Venetian blind
has reached the lower end stop (run to lower end
stop).
The drive starts, stops briefly and then moves on
(while the DOWN button ▼ is pushed).
The drive switches off automatically when the lower
limit stop is reached.
④
Press the AUF button ▲ until the drive stops auto-
matically.
The lower end position has been set.
Optional:
Activation of the relief function for the
lower stop; see chapter 5.6.3
Setting of the end positions variant C is now complete.
Fig. 10 End position setting Variant C: