elero RevoLine L RolTop L80 User Manual Download Page 5

17.6  Setting the end positions and the relief 

Important preliminary consideration: 

Decide on a specific relief function before setting the end 

positions (different combination options according to the 

following statements): 
This will save unnecessary setting effort! 
Press the travel key until the drive signals the transition into 

the setting mode, by a short automatic stop. You can now 

program the end positions. After setting the two end posi-

tions, the setting mode is completed. 

17.6.1 Relief function for the end position(s) 

If an end position is set to stop, an additional relief for the 

Venetian blind can be released. 

Important 

Activation of the relief function (in the versions B to D) takes 

place in one work step when the end positions are pro-

grammed (see chapter 5.6.7 to chapter 5.6.9)! 

17.6.2 Relief function at the upper stop 

For variant C (see chapter 5.6.7)  

and variant D (see chapter 5.6.8): 

Activate relief function at the upper stop. 

Push and hold the 

UP 

button ▲ from instruction 

 

(chapters 5.6.7 and 5.6.8) and actuate the 

DOWN 

 

button ▼ with the assembly cable (at the same time). 

Keep both buttons pushed until the Venetian blind 

stops. 

The relief function at the upper stop is activated. 

17.6.3 Relief function at the lower stop 

For version C (see chapter 5.6.8)  

and version D (see chapter 5.6.9): 

Activate relief function at the lower stop 

Push and hold the 

DOWNP 

button ▼ from instruction 

 (chapters 5.6.8 and 5.6.9) and actuate the 

UP 

 

button ▲ with the assembly cable (at the same time). 

Keep both buttons pushed until the Venetian blind 

stops. 

The relief function at the lower stop is activated. 

17.6.4 Changing / Deleting the limit positions  

and deleting the discharge function 

A change or deletion of a single end position is not possible. 

This is always done in pairs (upper and lower end position 

simultaneously). 
By the deletion of the end positions and the adjustment of 

the optional discharge function is lost. 

Important 

The Venetian blind is adjusted only after a complete and 

uninterrupted access and exit to the blind. 

Changing / Deleting the end positions 

From a middle Venetian blind position with the as-

sembly cable , push and hold both direction buttons 

(▲ and ▼) at the same time until the drive briefly 

moves up and down. 

The deletion of the setting of end position is completed. 
The end positions can be programmed again. 

17.6.5 Four variants of end position settings 

Four different combinations of end position settings are 

possible. They must be selected sensibly according to the 

technical requirements of the Venetian blind.

End position settings 

(4 versions) 

possible with 

A

 

Upper and lower end posi-

tion freely adjustable 

T-strap, tapes,  

belt 

B

Fixed upper limit stop / 

lower end position freely 

adjustable 

T-strap, tapes,  

belt, limit plugs,  

angle bracket 

C

 

Fixed upper and lower limit 

stop 

Anti push-up device, 

stiff shaft connector, 

limit plugs, angle 

bracket

D

Upper end position freely 

adjustable, fixed lower limit 

stop

Anti push-up device

Fig. 7    Versions of the end position settings in the RolTop 

17.6.6 Variant A:  Upper and lower end position 

freely adjustable 

Variant A:  

Upper and lower end position freely adjustable 

① 

 

From a middle Venetian blind position with the as-

sembly cable, push the 

UP 

button ▲ until the Vene-

tian blind has reached the desired end position. 
The drive starts, stops briefly and then moves on 

(while the UP button  ▲ is pushed). 
Correction is possible with the buttons  ▲ and ▼ . 

② 

 

Press the AB button ▼ until the drive stops auto-

matically. 
The upper end position has been set. 

③ 

 

Press the 

AB

 button ▼ again until the Venetian 

blind has reached the desired lower end stop.

 

The drive starts, stops briefly and then moves 

on (while the AB button 

▼  

is pushed). 

Correction is possible with the buttons  ▲ and ▼ . 

 

Press the AUF button 

▲ 

 until the drive stops 

automatically. 

The lower end position has been set. 

Setting of the end positions variant A is now complete. 

Fig. 8    End position setting Variant A: 

 

© 

elero

 GmbH

  

EN | 5

Commissioning | Setting the end positions and the relief 

Summary of Contents for RevoLine L RolTop L80

Page 1: ...g Instructions refer to the laws and regulations currently applicable in Germany All instructions in the Operating Instructions shall be ob served without limitation and at any time Beside the safety...

Page 2: ...the elero drive com putation program http elero de antriebsberechnungsprogramm Further fields of application have to be arranged with the manufacturer elero GmbH Antriebstechnik see Address The operat...

Page 3: ...WARNING Danger of injury due to electric current Electric shock possible Electrical work can only be performed by an authorized electrician Danger of injury due to electric current Hazardous possibly...

Page 4: ...the motor tube Look for an axial clearance 1 2 mm Installation in profile tubes Insert the drive with a suitable adapt er and traction ring into the profile tube Lay the motor cable protected in or de...

Page 5: ...al discharge function is lost Important The Venetian blind is adjusted only after a complete and uninterrupted access and exit to the blind Changing Deleting the end positions 1 From a middle Venetian...

Page 6: ...stop lower end position freely adjustable Variant B Fixed upper limit stop lower end posi tion freely adjustable From a middle Venetian blind position with the assembly cable push the UP button until...

Page 7: ...t 5 minutes after deactivation for the motor to cool down and the capaci tors to lose their voltage Use suitable tested and stable climbing aids when per forming disassembly work above body height All...

Page 8: ...er consumption W 118 140 200 270 300 Shaft diameter mm 50 Protection class IP 44 Limit switch range turns 40 Operating duration min S2 5 4 5 4 Length A mm 478 480 530 540 530 540 560 Length B mm 460 4...

Page 9: ...0 50 50 50 50 Rated torque Nm 1 5 3 5 5 8 10 12 12 Rated speed 1 min 70 30 30 17 17 17 17 11 Rated current A 0 55 0 55 0 73 0 55 0 73 0 55 0 73 0 55 Rated power consumption W 130 130 168 130 168 130 1...

Page 10: ...523 462 513 523 512 Weight kg 2 2 1 9 2 2 2 3 Operating environment temperature C 20 to 60 Conformity Emission sound pressure level dBA 70 Protection class I Plug in connecting cable m 2 0 Item numbe...

Reviews: