USA-16
USA-15
US
A
Programming weekly control commands/
Technical data/Battery replacement
Nominal voltage
3 V DC
Battery tape
2 x LR 03 (AAA)
System of protection
IP 20
Permissible ambient temperature
0 to +55 °C
Type of installation
Wall-mounted
Operating frequency
915,3 MHz
The maximum radio operating range is 25 m indoors and 350 m
outdoors.
Technical data
Deleting weekly control commands
1. To delete all weekly control commands, press the
week
programming button for 5 seconds or longer.
The control light will flash 3 times briefly to confirm.
Note:
If weekly control commands are deleted, your shutter/blind
will be operated on the basis of the stored daily control
commands.
Battery replacement
1. Open the battery compartment.
2. Insert the new batteries
properly
.
LR03 (AAA)
LR03 (AAA)
--
--
Note:
Batteries must be replaced
within one minute
.
Ensure that none of the
buttons on the device are
pressed
in the process
.
Programming weekly control commands
Programming weekly control commands
Weekly switching times settings can be made for every day of the
week.
The weekly control commands are not deleted if a daily control
command is changed.
Please note
: UP and DOWN control commands
must
be
programmed for the relevant days on which the control
commands are to be executed.
If the same function is programmed twice on the same
day, the old switching time is automatically overwritten.
UP control command
1. Press the
week
programming button briefly.
You now have
15 seconds
to programme the switching time for
the UP control command.
2. Press the
UP
button.
The control light will flash 3 times briefly to confirm.
The control command for the upper limit position has been
successfully programmed.
This control command will be automatically repeated every
7 days.
DOWN control command
1. Press the
week
programming button briefly.
You now have
15 seconds
to programme the switching time for
the DOWN control command.
2. Press the
DOWN
button.
The control light will flash 3 times briefly to confirm.
The control command for the lower limit position has been
successfully programmed.
This control command will be automatically repeated every
7 days.