23
FM TRANSMITTER
MEDIUM
POWER |
ETG3500
Asynchronous AM S/N unweighted
> = 55 dB a 400 Hz, 75 us de-emphasis
Synchronous AM S/N
> = 50 dB a 400 Hz, 75 us de-emphasis
Amplitude-frequency characteristic
(stereo/mono operation)
+/- 0.1 dB (without pre-emphasis)
+/- 0.1 dB (with pre-emphasis)
20 Hz to 15 KHz, @ 400 Hz
Stereo Crosstalk (typical)
60 dB
@ 400 Hz to 10 KHz
Linear crosstalk
>60 db 20 Hz to 15 KHz
Intermodulation distortion
<0.05% Measured with two of tones 1 KHz &
1.3 KHz, ratio 1:1 at 100% modulation
Class of emission
F3
Stereo emission
According to ITU-R reccomendation
450 (pilot tone)
EXCITER PERFORMANCE
PLL lock time
<10 sec
Frequency deviation
+/- 75 KHz 0.1 dB steps adjustable
Maximum frequency deviation
+/- 150 KHz
Frequency stability
1 ppm
RF Frequency steps
10 KHz
Phase Response
+/- 0.1 degree from linear phase;
20 KHz to 100 KHz
INSTALLATION REQUIREMENTS
Power supply
230/400 Threephase-Singlephase
Version 50-60 Hz VAC
Power consumption (typical)
4.9 KW
Overall efficiency (typical from -3 dB to Pnom)
> = 70%
Power factor
> 0.95
Current Consumption @ 230VAC/single phase
21.3 Amp
Magneto-thermic capacity @ 230VAC/single phase
32 Amp
Conductor size @ 230VAC/single phase
10 sqrt.mm
Conductor size @ 230VAC/single phase
7 AWG
Current Consumption @ 230VAC/three phase
12.5 Amp
Magneto-thermic capacity @ 230VAC/three phase
20 Amp
Conductor size @ 230VAC/three phase
6 sqrt.mm
Conductor size @ 230VAC/three phase
9 AWG
Current Consumption @ 400VAC/three phase
7.1 Amp
Magneto-thermic capacity @ 400VAC/three phase
16 Amp
Conductor size @ 400VAC/three phase
4 sqrt.mm
Conductor size @ 400VAC/three phase
11 AWG
COOLING/NOISE/DATA
Cooling system
Forced air-cooling . From 600 to 1200 m3/h
Air temperature increase
17 °C
Acoustic noise
< 65 phon
@ transmitter room, 2 m distance of the
front of transmitter
ENVIRONMENT
Temperature range (operating)
-5 ÷ +45 °C, 23 ÷ 113 °F
Temperature range (non operating)
-20 ÷ +55 °C, -4 ÷ 131 °F
Humidity range (operating)
95% @ 40 °C, 104 °F
Humidity range (non operating)
90% @ 55 °C, 131 °F
Altitude range (operating)
<3000 meters / <9840 Feet
Altitude range (non operating)
<15000 meters / < 49200 Feet
TELECONTROL & TELEMETRY
Remote control
Yes
Remote control, dry contacts
Yes
SNMP option
Yes (external)
Product description
Summary of Contents for ETG2500
Page 4: ......
Page 54: ...54 Main Men Profiles O Main Men Exciter monitor E Instructions for use...
Page 55: ...55 Main Men Status Alarms S Main Men Events History H Instructions for use...
Page 56: ...56 Main Men Password K Main Men Password K Password K Instructions for use...
Page 58: ...58 Main Men System Y Main Men System Y System settings X Instructions for use...
Page 59: ...59 Main Men System Y Comm settings U Main Men System Y Audio trim alrm J Instructions for use...
Page 60: ...60 Main Men System Y Clock power set C Main Men System Y SMS phone set P Instructions for use...
Page 61: ...61 Main Men System Y User warning F Main Men System Y En 0 31 alrm SMS V Instructions for use...
Page 63: ...63 Main Men Debug D Main Men Debug D GSM debug G Instructions for use...
Page 64: ...64 Main Men Debug D Uarts F Main Men Debug D Uarts F Uart 0 1 2 Instructions for use...
Page 67: ...67 CAB0324 0 CAB0324 0 CAB0324 0 Instructions for use...
Page 70: ...70 CN1 CN2 CN3 CN4 CN5 CN6 CN7 Maintenance CONCENTRATOR BOARD...
Page 71: ...71 n 2 n 1 n 3 n 4 n 5 n 6 n 7 Maintenance RF MODULES...
Page 72: ...72 Maintenance...
Page 74: ...74 n 2 n 1 n 3 SW1 SW2 Maintenance POWER SUPPLIES...
Page 78: ...78 Maintenance...