17
Product description
open
collector
23
Bad audio
Signaling output
The pin must be po-
wered externally.
“Closed to ground”
status
→
Active alarm
open
collector
24
/FLT (reversed pola-
rity)
Signaling output
The pin must be po-
wered externally.
“Open” Status
→
Acti-
ve alarm
The operation can be
affected by the set-
tings of the machine
open
collector
25
Remote
Signaling output
The pin must be po-
wered externally.
“Closed to ground”
status
→
Remote
signal active
2.1.7.1 Full scale values
The nominal full scale corresponds to +4 V, with over stroke of up to more than +4.5
(max +5 V).
ETG5000
Parameters
Full scale
Scale factor
Resolution
Forward power
5000W
1250W * V
Full scale/204
Reflected power
500W
125W * V
IPA (current amplifier)
200A
50A * V
VPA (voltage amplifier)
50V
12.5V * V
ETG3500
Parameters
Full scale
Scale factor
Resolution
Forward power
3500W
875W * V
Full scale/204
Reflected power
350W
87.5W * V
IPA (current amplifier)
150A
37.5A * V
VPA (voltage amplifier)
50V
12.5V * V
ETG2500
Parameters
Full scale
Scale factor
Resolution
Forward power
2500W
625W * V
Full scale/204
Reflected power
250W
62.5W * V
IPA (current amplifier)
150A
37.5A * V
VPA (voltage amplifier)
50V
12.5V * V
Summary of Contents for ETG2500
Page 4: ......
Page 54: ...54 Main Men Profiles O Main Men Exciter monitor E Instructions for use...
Page 55: ...55 Main Men Status Alarms S Main Men Events History H Instructions for use...
Page 56: ...56 Main Men Password K Main Men Password K Password K Instructions for use...
Page 58: ...58 Main Men System Y Main Men System Y System settings X Instructions for use...
Page 59: ...59 Main Men System Y Comm settings U Main Men System Y Audio trim alrm J Instructions for use...
Page 60: ...60 Main Men System Y Clock power set C Main Men System Y SMS phone set P Instructions for use...
Page 61: ...61 Main Men System Y User warning F Main Men System Y En 0 31 alrm SMS V Instructions for use...
Page 63: ...63 Main Men Debug D Main Men Debug D GSM debug G Instructions for use...
Page 64: ...64 Main Men Debug D Uarts F Main Men Debug D Uarts F Uart 0 1 2 Instructions for use...
Page 67: ...67 CAB0324 0 CAB0324 0 CAB0324 0 Instructions for use...
Page 70: ...70 CN1 CN2 CN3 CN4 CN5 CN6 CN7 Maintenance CONCENTRATOR BOARD...
Page 71: ...71 n 2 n 1 n 3 n 4 n 5 n 6 n 7 Maintenance RF MODULES...
Page 72: ...72 Maintenance...
Page 74: ...74 n 2 n 1 n 3 SW1 SW2 Maintenance POWER SUPPLIES...
Page 78: ...78 Maintenance...