V. 07-21
www.plycem.com
V. 10-21
www.plycem.com
3
INSTALLATION GUIDE FOR EUREKA TANK
•
Make sure the level of the support surface of the tank.
•
Make sure that the support surface is larger than the bottom
of the tank.
•
Do not place the tank on irregular fl oor.
•
Do not place the tank on separate parts or beams.
•
Do not install the tank underground.
•
Do not place the tank on irregular surfaces, vegetation, roots
or elements that may damage the bottom of the tank.
Installation precaution
◾
Tanks should be washed before installation.
◾
The tank should be always cleaned every six months. Check the
fi lter and connections and make the necessary adjustments
and repairs.
◾
The tank should be always covered.
◾
When using a pumping system, the pipe should be anchored at
the tank inlet to absorb any movement over the tank connector.
◾
The system should be installed in an easily accessible location
to allow for inspection and to facilitate proper maintenance.
◾
When storing the tank prior to installation, be sure to keep it in an
upright position on a smooth, level surface.
◾
The temperature of the liquid to be stored must not exceed 60°
Celsius.
◾
For the installation of additional accessories to the tank, it
is important to consult with your distributor warehouse. It is
important that you consult your authorized supplier beforehand.
Installation provisions
Multi connector installation.
Your tank (1) has a threaded fl ange (2). Screw on the
multi connector (3) with 1/2” or 3/4” outlet. Use the one that
corresponds to the diameter of your distribution pipe (5). Use only
your hands to tighten it. Turn until the threaded plug of the air jug
(4) is facing upwards and the cleaning plug (6) is on one side as
shown in the fi gure. Remove the plug and insert the air jug tube (4).
Connect the multi-connector (3) to the distribution pipe.
Step 3
1
2
3
4
5
6
Control alternatives (1 and 2) valve and fl oat.
To install the valve and fl oat your tank has a hole (3) in the top neck
to insert the water supply tube (5), at the end of the tube, using a
union (4) (not included). Install the valve and fl oat (1 and 2) as shown.
2. Electronic level (electrode not included). Its new tank has a
special base that allows the placement of an electrode.
Place Tefl on tape (not included) on all pipe threads and fi ttings to
be installed.
Step 2
1
2
3
4 5
Male adapters 1/2”
Float
Filter
Multi connector
valve
Tee PVC 1/2”
PVC elbow 1/2”
Shut-off
valve
Water inlet and
outlet
Outlet pipe
support
Connecting
flange
PVC elbow 1/2”
Check
valve
Air jug