INSTALLATION GUIDE FOR EUREKA TANK

• 

Make sure the level of the support surface of the tank.

• 

Make sure that the support surface is larger than the bottom 
of the tank.

• 

Do not place the tank on irregular fl oor.

• 

Do not place the tank on separate parts or beams. 

• 

Do not install the tank underground.

• 

Do not place the tank on irregular surfaces, vegetation, roots 
or elements that may damage the bottom of the tank.

Installation precaution

Tanks should be washed before installation.

The tank should be always cleaned every six months. Check the 

fi lter  and  connections  and  make  the  necessary  adjustments 

and repairs.

The tank should be always covered.

When using a pumping system, the pipe should be anchored at 
the tank inlet to absorb any movement over the tank connector.

The system should be installed in an easily accessible location 
to allow for inspection and to facilitate proper maintenance.

When storing the tank prior to installation, be sure to keep it in an 
upright position on a smooth, level surface.

The temperature of the liquid to be stored must not exceed 60° 

Celsius.

For the installation of additional accessories to the tank, it 
is important to consult with your distributor warehouse. It is 
important that you consult your authorized supplier beforehand.

Installation provisions

Multi connector installation.

Your  tank  (1)  has  a  threaded  fl ange  (2).  Screw  on  the                                                       
multi  connector  (3)  with  1/2”  or  3/4”  outlet.  Use  the  one  that 

corresponds to the diameter of your distribution pipe (5). Use only 

your hands to tighten it. Turn until the threaded plug of the air jug 
(4)  is  facing  upwards  and  the  cleaning  plug  (6)  is  on  one  side  as 
shown in the fi gure. Remove the plug and insert the air jug tube (4).
Connect  the  multi-connector  (3)  to  the  distribution  pipe. 

Step 3

1

2

3

4

5

6

Control alternatives (1 and 2) valve and fl oat.
To install the valve and fl oat your tank has a hole (3) in the top neck 

to insert the water supply tube (5), at the end of the tube, using a 

union (4) (not included). Install the valve and fl oat (1 and 2) as shown.

2.  Electronic  level  (electrode  not  included).  Its  new  tank  has  a 

special base that allows the placement of an electrode.

Place Tefl on tape (not included) on all pipe threads and fi ttings to 

be installed.

Step 2

1

2

3

4 5

Male adapters 1/2”

Float 

Filter

Multi connector 

valve

Tee PVC 1/2”

PVC elbow 1/2”

Shut-off 

valve

Water inlet and

 outlet

Outlet pipe 

support

Connecting 

flange 

PVC elbow 1/2”

Check 

valve

Air jug

Summary of Contents for Plycem Eureka Tank

Page 1: ...IMPACT RESISTANT LIGHTWEIGHT HERMETIC HYGIENIC DURABLE EASY TO INSTALL ECO FRIENDLY EASY TO CLEAN EUREKA TANK Installation guide ...

Page 2: ...er coating prevents penetration of UV rays and sunlight prevents algae With an intermediate layer three layer that resists UV rays and protects against solar rays prevents algae and microorganisms LidwithClicklock seals the tank and makes it easy to close or remove the lid The flange cover and ring are replaceable as well as the filter and other components With reinforcement struts and structured ...

Page 3: ...uded 1 1 2 female adapter 2 reductions from 3 4 to 1 2 2 3 4 male adapters 3 1 2 male adapters 2 1 2 elbows 1 1 2 check valve 1 tee of 1 2 1 ball valve of 1 2 1 2 pipe Connectionaccessories Before installing the tank at the installation site aspects such as topography soil types floodable areas nearby vegetation etc among others should be reviewed nearby vegetation etc and others This is in order t...

Page 4: ...he installation of additional accessories to the tank it is important to consult with your distributor warehouse It is important that you consult your authorized supplier beforehand Installationprovisions Multi connector installation Your tank 1 has a threaded flange 2 Screw on the multi connector 3 with 1 2 or 3 4 outlet Use the one that corresponds to the diameter of your distribution pipe 5 Use ...

Page 5: ..._____________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ Plycem warrants that if a product of its brand proves to be defective in materials or in the manufacturing process within 100 years 5 years for accessories from the d...

Page 6: ...RicaS A INTE ISO 14001 2015 SGA 008 01 2010 SISTEMA DE GESTIÓN AMBIENTAL CERTIFICADO 001 CP 2001 PRODUCTO CERTIFICADO 069 CP 2013 PRODUCTO CERTIFICADO INTE ISO 45001 2018 SST 009 2020 SISTEMA DE GESTIÓN DE LA SEGURIDAD Y SALUD EN EL TRABAJO CERTIFICADO INTE ISO 45001 2018 SST 006 2020 SISTEMA DE GESTIÓN DE LA SEGURIDAD Y SALUD EN EL TRABAJO CERTIFICADO Manufacturedby ...

Reviews: